Nutone Central Air Conditioner Condenser fan motor does not run
If your NuTone central air conditioner has a condenser fan not running, the outdoor condenser fan may not spin even though the system calls for cooling. The most likely cause is a failed run capacitor, which can make the fan motor noisy, cause it to overheat, or keep it from starting. Next, a defective motor control board can prevent the motor from running or operating at the correct speed. If the capacitor looks normal, the fan motor itself may have failed. Other possible causes include a faulty condenser motor, capacitor, or condenser fan motor. A multimeter test can confirm whether the motor is receiving the proper voltage, but the outdoor condensing unit contains hazardous 240-volt wiring. Turn off power at the disconnect box and circuit breaker, and have a qualified HVAC technician handle live-voltage testing or wiring repairs. Refrigerant work and any repair inside the sealed system require an EPA 608-certified technician. You can safely inspect for a bulging or leaking capacitor, then enter your NuTone model number to find the exact replacement run capacitor, motor control board, fan motor, or condenser fan motor for your specific central air conditioner.
01 - Nutone Central Air Conditioner Run Capacitor
If the run capacitor is defective, the fan motor might be noisy, overheat, or not run at all. To determine if the run capacitor has failed, inspect the capacitor. If the run capacitor is bulging or leaking, replace it.
Enter model number to search for the required part specific to your product
02 - Nutone Central Air Conditioner Motor Control Board
The motor control board helps to maintain the desired motor speed of the blower. When the motor control board fails, the blower motor may not run at the correct speed or it may not run at all.
To determine if the fan motor is working, use a multimeter to test the incoming voltage to the motor. If the fan motor is receiving the correct voltage but the motor still won’t run, inspect the capacitor to ensure that it is not at fault. If the capacitor is not bulging or leaking, replace the fan motor.
To determine if the condenser motor is working, use a multimeter to test the incoming voltage to the motor. If the condenser fan motor is receiving the correct voltage but the motor still won’t run, inspect the capacitor to ensure that it is not at fault. If the capacitor is not bulging or leaking, replace the condenser fan motor.
If the capacitor is defective, the fan motor might be noisy, overheat, or not run at all. To determine if the capacitor has failed, inspect the capacitor. If the capacitor is bulging or leaking, replace it.
06 - Nutone Central Air Conditioner Condenser Fan Motor
To determine if the condenser motor is working, use a multimeter to test the incoming voltage to the motor. If the condenser fan motor is receiving the correct voltage but the motor still won’t run, inspect the capacitor to ensure that it is not at fault. If the capacitor is not bulging or leaking, replace the condenser fan motor.