Coleman Central Air Conditioner Condenser fan motor does not run

If your Coleman central air conditioner's condenser fan is not running, the most likely cause is a failed run capacitor. A bulging or leaking capacitor can make the fan motor noisy, cause it to overheat, or keep it from starting. Next, a faulty motor control board may prevent the motor from operating or running at the correct speed. If the board and capacitor are working, the condenser fan motor itself may have failed. Less commonly, the condenser motor or another capacitor is defective. This condenser fan troubleshooting guide can help identify whether the outdoor AC fan is not spinning because the motor is not receiving power or because the motor has failed. Turn off power at the disconnect box and circuit breaker before inspecting parts. Testing incoming voltage requires working around 240V line voltage, so have a qualified HVAC technician handle electrical testing or repairs beyond your comfort level. No refrigerant work is covered here, but any repair inside the sealed system requires an EPA 608-certified technician. Enter your Coleman model number to find the exact run capacitor, motor control board, fan motor, or condenser fan motor for your central air conditioner.

01 - Coleman Central Air Conditioner Run Capacitor

If the run capacitor is defective, the fan motor might be noisy, overheat, or not run at all. To determine if the run capacitor has failed, inspect the capacitor. If the run capacitor is bulging or leaking, replace it.
Enter model number to search for the required part specific to your product
Common

02 - Coleman Central Air Conditioner Motor Control Board

The motor control board helps to maintain the desired motor speed of the blower. When the motor control board fails, the blower motor may not run at the correct speed or it may not run at all.
Common

03 - Coleman Central Air Conditioner Fan Motor

To determine if the fan motor is working, use a multimeter to test the incoming voltage to the motor. If the fan motor is receiving the correct voltage but the motor still won’t run, inspect the capacitor to ensure that it is not at fault. If the capacitor is not bulging or leaking, replace the fan motor.
Common

04 - Coleman Central Air Conditioner Motor

To determine if the condenser motor is working, use a multimeter to test the incoming voltage to the motor. If the condenser fan motor is receiving the correct voltage but the motor still won’t run, inspect the capacitor to ensure that it is not at fault. If the capacitor is not bulging or leaking, replace the condenser fan motor.
Common

05 - Coleman Central Air Conditioner Capacitor

If the capacitor is defective, the fan motor might be noisy, overheat, or not run at all. To determine if the capacitor has failed, inspect the capacitor. If the capacitor is bulging or leaking, replace it.
Common

06 - Coleman Central Air Conditioner Condenser Fan Motor

To determine if the condenser motor is working, use a multimeter to test the incoming voltage to the motor. If the condenser fan motor is receiving the correct voltage but the motor still won’t run, inspect the capacitor to ensure that it is not at fault. If the capacitor is not bulging or leaking, replace the condenser fan motor.
Less Common

Frequently Asked Questions

Why is my Coleman condenser fan not running?
How do I test a condenser fan motor that is not spinning?
Can a bad capacitor cause the outdoor AC fan to stop working?
Should I run my AC if the condenser fan is not spinning?
How do I find the correct Coleman condenser fan motor or capacitor?