Heil Central Air Conditioner Condenser fan motor does not run

If your Heil central air conditioner's condenser fan is not running, the outdoor AC fan may not be spinning even though the system has power. The most likely cause is a failed run capacitor, which can make the condenser fan motor noisy, overheat, or stop completely. A defective motor control board is another possibility, followed by a failed fan motor. If the motor receives the correct voltage but does not run, inspect the capacitor before replacing the motor. A separate capacitor or condenser fan motor can also fail, though these are less common causes. This condenser fan troubleshooting involves 240V line voltage, so turn off power at the disconnect box and circuit breaker before inspecting the condensing unit. Testing voltage with a multimeter or replacing electrical components should be handled by a qualified technician if you are not trained for live electrical work. The run capacitor, motor control board, fan motor, capacitor, and condenser fan motor are serviceable parts, but do not open the sealed refrigerant system. Enter your Heil central air conditioner model number to find the exact replacement part for your specific unit and verify fit before ordering.

01 - Heil Central Air Conditioner Run Capacitor

If the run capacitor is defective, the fan motor might be noisy, overheat, or not run at all. To determine if the run capacitor has failed, inspect the capacitor. If the run capacitor is bulging or leaking, replace it.
Enter model number to search for the required part specific to your product
Common

02 - Heil Central Air Conditioner Motor Control Board

The motor control board helps to maintain the desired motor speed of the blower. When the motor control board fails, the blower motor may not run at the correct speed or it may not run at all.
Common

03 - Heil Central Air Conditioner Fan Motor

To determine if the fan motor is working, use a multimeter to test the incoming voltage to the motor. If the fan motor is receiving the correct voltage but the motor still won’t run, inspect the capacitor to ensure that it is not at fault. If the capacitor is not bulging or leaking, replace the fan motor.
Common

04 - Heil Central Air Conditioner Motor

To determine if the condenser motor is working, use a multimeter to test the incoming voltage to the motor. If the condenser fan motor is receiving the correct voltage but the motor still won’t run, inspect the capacitor to ensure that it is not at fault. If the capacitor is not bulging or leaking, replace the condenser fan motor.
Common

05 - Heil Central Air Conditioner Capacitor

If the capacitor is defective, the fan motor might be noisy, overheat, or not run at all. To determine if the capacitor has failed, inspect the capacitor. If the capacitor is bulging or leaking, replace it.
Common

06 - Heil Central Air Conditioner Condenser Fan Motor

To determine if the condenser motor is working, use a multimeter to test the incoming voltage to the motor. If the condenser fan motor is receiving the correct voltage but the motor still won’t run, inspect the capacitor to ensure that it is not at fault. If the capacitor is not bulging or leaking, replace the condenser fan motor.
Less Common

Frequently Asked Questions

Why is my Heil central air conditioner condenser fan not running?
Can a bad capacitor cause the condenser fan motor to stop spinning?
How do I test a Heil condenser fan motor that is not running?
Why is my central air conditioner not cooling when the outdoor fan is not spinning?
How do I find the correct Heil condenser fan motor or capacitor for my air conditioner?