Choose Product
Identify Problem
03
Find Solutions

Philco Central Air Conditioner Condenser fan motor does not run

If your Philco central air conditioner's condenser fan is not running, the most likely cause is a failed run capacitor. A defective capacitor can make the condenser fan motor noisy, cause it to overheat, or keep it from starting. Next, check the motor control board, which can prevent the motor from running or maintaining the correct speed. If the board and capacitor are good, the condenser fan motor itself may have failed. The page also lists the condenser fan motor and capacitor as possible replacement parts, with the condenser fan motor being less common. This condenser fan troubleshooting requires care because the outdoor unit contains 240V line voltage, and a capacitor can retain a dangerous charge after power is disconnected. Turn off power at the disconnect box and circuit breaker before inspecting anything, and use a qualified HVAC technician for live-voltage testing or electrical repairs beyond your experience. Refrigerant work is not part of this diagnosis, but any sealed-system repair requires an EPA 608-certified technician. Enter your Philco model number to find the exact replacement run capacitor, motor control board, or condenser fan motor for your central air conditioner.

01 - Philco Central Air Conditioner Run Capacitor

If the run capacitor is defective, the fan motor might be noisy, overheat, or not run at all. To determine if the run capacitor has failed, inspect the capacitor. If the run capacitor is bulging or leaking, replace it.
Enter model number to search for the required part specific to your product
Common

02 - Philco Central Air Conditioner Motor Control Board

The motor control board helps to maintain the desired motor speed of the blower. When the motor control board fails, the blower motor may not run at the correct speed or it may not run at all.
Common

03 - Philco Central Air Conditioner Fan Motor

To determine if the fan motor is working, use a multimeter to test the incoming voltage to the motor. If the fan motor is receiving the correct voltage but the motor still won’t run, inspect the capacitor to ensure that it is not at fault. If the capacitor is not bulging or leaking, replace the fan motor.
Common

04 - Philco Central Air Conditioner Motor

To determine if the condenser motor is working, use a multimeter to test the incoming voltage to the motor. If the condenser fan motor is receiving the correct voltage but the motor still won’t run, inspect the capacitor to ensure that it is not at fault. If the capacitor is not bulging or leaking, replace the condenser fan motor.
Common

05 - Philco Central Air Conditioner Capacitor

If the capacitor is defective, the fan motor might be noisy, overheat, or not run at all. To determine if the capacitor has failed, inspect the capacitor. If the capacitor is bulging or leaking, replace it.
Common

06 - Philco Central Air Conditioner Condenser Fan Motor

To determine if the condenser motor is working, use a multimeter to test the incoming voltage to the motor. If the condenser fan motor is receiving the correct voltage but the motor still won’t run, inspect the capacitor to ensure that it is not at fault. If the capacitor is not bulging or leaking, replace the condenser fan motor.
Less Common

Frequently Asked Questions

Why is my Philco condenser fan not running?
How do I test a Philco condenser fan motor that is not spinning?
Can a bad capacitor cause a noisy condenser fan or an AC fan motor that will not run?
Could a Philco motor control board be causing the condenser fan not to run?
How do I find the correct Philco condenser fan motor or capacitor?

Shop by Philco Central Air Conditioner Parts