Maytag Central Air Conditioner Condenser fan motor does not run
When your Maytag central air conditioner has a condenser fan not running, the run capacitor is the most likely cause. A failed capacitor can make the fan motor noisy, cause it to overheat, or keep it from starting; replace it if it is bulging or leaking. Next, check the motor control board, which can prevent the blower or fan motor from running at the correct speed. A technician can use a multimeter to verify whether the condenser fan motor receives the correct voltage. If voltage is present and the capacitor is good, the motor likely needs replacement. Turn off power at the disconnect box and circuit breaker before inspecting parts. Testing or repairing 240V wiring is not a beginner DIY repair, so have a qualified HVAC technician handle live-voltage diagnosis or electrical work. This problem does not normally require refrigerant handling, but any sealed-system repair does require EPA 608 certification. Enter your Maytag model number to find the exact run capacitor, motor control board, or condenser fan motor for your central air conditioner.
01 - Maytag Central Air Conditioner Run Capacitor
If the run capacitor is defective, the fan motor might be noisy, overheat, or not run at all. To determine if the run capacitor has failed, inspect the capacitor. If the run capacitor is bulging or leaking, replace it.
Enter model number to search for the required part specific to your product
02 - Maytag Central Air Conditioner Motor Control Board
The motor control board helps to maintain the desired motor speed of the blower. When the motor control board fails, the blower motor may not run at the correct speed or it may not run at all.
To determine if the fan motor is working, use a multimeter to test the incoming voltage to the motor. If the fan motor is receiving the correct voltage but the motor still won’t run, inspect the capacitor to ensure that it is not at fault. If the capacitor is not bulging or leaking, replace the fan motor.
To determine if the condenser motor is working, use a multimeter to test the incoming voltage to the motor. If the condenser fan motor is receiving the correct voltage but the motor still won’t run, inspect the capacitor to ensure that it is not at fault. If the capacitor is not bulging or leaking, replace the condenser fan motor.
If the capacitor is defective, the fan motor might be noisy, overheat, or not run at all. To determine if the capacitor has failed, inspect the capacitor. If the capacitor is bulging or leaking, replace it.
06 - Maytag Central Air Conditioner Condenser Fan Motor
To determine if the condenser motor is working, use a multimeter to test the incoming voltage to the motor. If the condenser fan motor is receiving the correct voltage but the motor still won’t run, inspect the capacitor to ensure that it is not at fault. If the capacitor is not bulging or leaking, replace the condenser fan motor.