Goodman Central Air Conditioner Condensing unit does not run

When a Goodman condensing unit does not run, the problem may be the compressor, wall thermostat, condenser fan motor, fan motor, or a sealed-system safety control. A bad run capacitor or a tripped circuit breaker or blown fuse is the most likely cause when the outdoor unit is completely dead. A failed compressor is a possible but less common cause. A defective wall thermostat can stop both the furnace and condensing unit from operating, while a seized condenser fan motor can also keep the outdoor AC unit from running. If the unit has power but neither the fan nor compressor starts, low refrigerant may have tripped the low pressure switch. A high pressure switch or other pressure switch can also interrupt operation. Turn off power at the disconnect box and circuit breaker before inspecting components. Testing or replacing parts in a 240V condensing unit requires electrical safety precautions and may be beyond DIY scope. Refrigerant diagnostics, pressure-switch replacement, compressor replacement, and any repair inside the sealed system require an EPA 608-certified HVAC technician. Enter your Goodman model number to find the exact replacement compressor, thermostat, condenser fan motor, fan motor, or pressure switch for your central air conditioner.

01 - Goodman Central Air Conditioner Compressor

Central air conditioners use a compressor to pump refrigerant through the condenser coils located in the outside condensing unit and through the evaporator coils mounted on top of the furnace or air handler. While it's not a common problem, if the compressor fails, the condensing unit will not run. You can use a multimeter to test the compressor for electrical continuity, a continuous electrical path present in the component, to help determine if the compressor is faulty. If all other potentially defective components, such as the capacitor and condenser fan motor, are operating properly, then a qualified technician should ...replace the compressor.
Enter model number to search for the required part specific to your product
Highly Likely

02 - Goodman Central Air Conditioner Wifi Thermostat

The WiFi thermostat has contacts in it that control the furnace. If the contact fails it can result in the furnace and the condensing unit to not run at all.
Common

03 - Goodman Central Air Conditioner Condenser Fan Motor

A faulty condenser fan motor can be responsible for the central air conditioner condensing unit not running. You can use a multimeter to test the fan motor for electrical continuity, a continuous electrical path present in the motor, to help determine if the motor is defective. You can also use the multimeter to determine if power is reaching the motor. You can also try rotating the fan blades by hand. If the blades do not turn freely, it's likely the motor bearings have seized and the fan motor will need to be replaced.
Common

04 - Goodman Central Air Conditioner Fan Motor

A faulty fan motor can be responsible for the central air conditioner condensing unit not running. You can use a multimeter to test the fan motor for electrical continuity, a continuous electrical path present in the motor, to help determine if the motor is defective. You can also use the multimeter to determine if power is reaching the motor. You can also try rotating the fan blades by hand. If the blades do not turn freely, it's likely the motor bearings have seized and the fan motor will need to be replaced.
Common

05 - Sealed system problem

If the condensing unit has power to it, the contactor checks out okay, but the fan and compressor are not running, it is likely that the unit is low on refrigerant which will cause the low limit pressure switch to trip and keep the unit from running. Since diagnosing and repairing a sealed system takes specialized tools and knowledge, a qualified service technician should diagnosis and repair the unit.
Common

06 - Goodman Central Air Conditioner Pressure Switch

A pressure switch is a safety device used to help prevent component and system failures. There are basically three types of pressure switches used in central air conditioning and heat pump applications: High Limit, Low Limit, and Ambient Temperature. Depending on the model, you may have one or more of these or none. The pressure switch(es) can be checked with a multimeter, referencing the wiring diagram for the circuit locations. Note: If a pressure switch needs to be replaced the refrigerant will need to be removed, requiring a qualified technician.
Less Common

Frequently Asked Questions

Why is my Goodman central AC condensing unit not turning on?
What should I check if the condenser fan is not running?
Why is my AC compressor not running when the outdoor unit has power?
Why won't my AC condensing unit start if the fan and compressor are both off?
How do I find the correct Goodman AC replacement part?

Shop by Goodman Central Air Conditioner Parts