Luxaire Central Air Conditioner Condensing unit does not run

If your Luxaire AC condenser is not turning on, the outdoor AC unit may be completely silent even though the thermostat calls for cooling. The most likely cause is a failed compressor, followed by a faulty wall thermostat, condenser fan motor, or fan motor. A compressor can be checked for electrical continuity, but replacement requires a qualified HVAC technician. If the contactor has power but neither the compressor nor fan runs, a sealed-system problem may have caused the low pressure switch to trip because of low refrigerant. A defective pressure switch is less common and requires refrigerant removal for replacement. Check the thermostat settings and wiring, then inspect whether the condenser fan blade turns freely with power disconnected. Testing the compressor, motors, contactor, capacitor, thermostat, or pressure switch involves hazardous 240V line voltage, so use a qualified technician unless you have the proper training. Any refrigerant diagnosis or repair requires EPA 608 certification. Enter your Luxaire model number to find the exact replacement part for your central air conditioner, whether the condensing unit won't start, the outdoor AC unit is not running, or the outside unit is not turning on.

01 - Luxaire Central Air Conditioner Compressor

Central air conditioners use a compressor to pump refrigerant through the condenser coils located in the outside condensing unit and through the evaporator coils mounted on top of the furnace or air handler. While it's not a common problem, if the compressor fails, the condensing unit will not run. You can use a multimeter to test the compressor for electrical continuity, a continuous electrical path present in the component, to help determine if the compressor is faulty. If all other potentially defective components, such as the capacitor and condenser fan motor, are operating properly, then a qualified technician should ...replace the compressor.
Enter model number to search for the required part specific to your product
Highly Likely

02 - Luxaire Central Air Conditioner Wifi Thermostat

The WiFi thermostat has contacts in it that control the furnace. If the contact fails it can result in the furnace and the condensing unit to not run at all.
Common

03 - Luxaire Central Air Conditioner Condenser Fan Motor

A faulty condenser fan motor can be responsible for the central air conditioner condensing unit not running. You can use a multimeter to test the fan motor for electrical continuity, a continuous electrical path present in the motor, to help determine if the motor is defective. You can also use the multimeter to determine if power is reaching the motor. You can also try rotating the fan blades by hand. If the blades do not turn freely, it's likely the motor bearings have seized and the fan motor will need to be replaced.
Common

04 - Luxaire Central Air Conditioner Fan Motor

A faulty fan motor can be responsible for the central air conditioner condensing unit not running. You can use a multimeter to test the fan motor for electrical continuity, a continuous electrical path present in the motor, to help determine if the motor is defective. You can also use the multimeter to determine if power is reaching the motor. You can also try rotating the fan blades by hand. If the blades do not turn freely, it's likely the motor bearings have seized and the fan motor will need to be replaced.
Common

05 - Sealed system problem

If the condensing unit has power to it, the contactor checks out okay, but the fan and compressor are not running, it is likely that the unit is low on refrigerant which will cause the low limit pressure switch to trip and keep the unit from running. Since diagnosing and repairing a sealed system takes specialized tools and knowledge, a qualified service technician should diagnosis and repair the unit.
Common

06 - Luxaire Central Air Conditioner Pressure Switch

A pressure switch is a safety device used to help prevent component and system failures. There are basically three types of pressure switches used in central air conditioning and heat pump applications: High Limit, Low Limit, and Ambient Temperature. Depending on the model, you may have one or more of these or none. The pressure switch(es) can be checked with a multimeter, referencing the wiring diagram for the circuit locations. Note: If a pressure switch needs to be replaced the refrigerant will need to be removed, requiring a qualified technician.
Less Common

Frequently Asked Questions

Why is my Luxaire AC condenser not turning on?
What should I check if the outdoor AC fan is not spinning?
Can low refrigerant cause my AC condensing unit not to run?
How do I know whether the compressor is bad when my Luxaire AC will not start?
How do I find the correct Luxaire AC replacement part?