Garrison Central Air Conditioner Condensing unit does not run

If your Garrison central air conditioner condensing unit does not run, a bad run capacitor or a tripped circuit breaker or blown fuse is the most likely cause. A failed compressor is a possible but less common cause. A failed compressor can stop the outdoor unit from pumping refrigerant even when the indoor furnace or air handler operates. Next, a faulty wall thermostat may have failed contacts and prevent both the furnace and condensing unit from starting. A defective condenser fan motor can also leave the outdoor AC unit not running, especially if the condenser fan blade will not turn freely because the motor bearings have seized. If the unit has power but neither the compressor nor fan runs, a sealed-system problem, such as low refrigerant that trips the low pressure switch, is possible. A failed high or low pressure switch is less common. Testing continuity or power involves 240V components, including the contactor and capacitor, so use caution and have a qualified HVAC technician handle line-voltage diagnosis. Any refrigerant or sealed-system repair requires EPA 608 certification. Enter your Garrison model number to find the exact replacement compressor, thermostat, condenser fan motor, fan motor, or pressure switch for your central air conditioner.

01 - Garrison Central Air Conditioner Compressor

Central air conditioners use a compressor to pump refrigerant through the condenser coils located in the outside condensing unit and through the evaporator coils mounted on top of the furnace or air handler. While it's not a common problem, if the compressor fails, the condensing unit will not run. You can use a multimeter to test the compressor for electrical continuity, a continuous electrical path present in the component, to help determine if the compressor is faulty. If all other potentially defective components, such as the capacitor and condenser fan motor, are operating properly, then a qualified technician should ...replace the compressor.
Enter model number to search for the required part specific to your product
Highly Likely

02 - Garrison Central Air Conditioner Wifi Thermostat

The WiFi thermostat has contacts in it that control the furnace. If the contact fails it can result in the furnace and the condensing unit to not run at all.
Common

03 - Garrison Central Air Conditioner Condenser Fan Motor

A faulty condenser fan motor can be responsible for the central air conditioner condensing unit not running. You can use a multimeter to test the fan motor for electrical continuity, a continuous electrical path present in the motor, to help determine if the motor is defective. You can also use the multimeter to determine if power is reaching the motor. You can also try rotating the fan blades by hand. If the blades do not turn freely, it's likely the motor bearings have seized and the fan motor will need to be replaced.
Common

04 - Garrison Central Air Conditioner Fan Motor

A faulty fan motor can be responsible for the central air conditioner condensing unit not running. You can use a multimeter to test the fan motor for electrical continuity, a continuous electrical path present in the motor, to help determine if the motor is defective. You can also use the multimeter to determine if power is reaching the motor. You can also try rotating the fan blades by hand. If the blades do not turn freely, it's likely the motor bearings have seized and the fan motor will need to be replaced.
Common

05 - Sealed system problem

If the condensing unit has power to it, the contactor checks out okay, but the fan and compressor are not running, it is likely that the unit is low on refrigerant which will cause the low limit pressure switch to trip and keep the unit from running. Since diagnosing and repairing a sealed system takes specialized tools and knowledge, a qualified service technician should diagnosis and repair the unit.
Common

06 - Garrison Central Air Conditioner Pressure Switch

A pressure switch is a safety device used to help prevent component and system failures. There are basically three types of pressure switches used in central air conditioning and heat pump applications: High Limit, Low Limit, and Ambient Temperature. Depending on the model, you may have one or more of these or none. The pressure switch(es) can be checked with a multimeter, referencing the wiring diagram for the circuit locations. Note: If a pressure switch needs to be replaced the refrigerant will need to be removed, requiring a qualified technician.
Less Common

Frequently Asked Questions

Why is my Garrison outdoor AC unit not running?
What should I check if the Garrison condenser fan is not spinning?
Can a thermostat cause my Garrison condensing unit not to turn on?
Could low refrigerant make my Garrison condensing unit stop running?
How do I find the correct replacement part for my Garrison central air conditioner?

Shop by Garrison Central Air Conditioner Parts