Inglis Dryer tripping breaker

If your Inglis dryer is tripping the breaker or keeps tripping the breaker, start with the most likely causes so you can fix it without guessing. A weak or worn circuit breaker is the top suspect; breakers can weaken with age and trip below their rated amperage, so if you’ve checked dryer parts, have an electrician test or replace the breaker. Next, look for a shorted heating element or heating element assembly—use a multimeter to check each terminal for continuity to the case; continuity to the case means the element is shorted and needs replacing. Faulty power cord terminals, a damaged terminal block, or loose and burnt connections are common culprits too, so shut off power and inspect the cord and terminal block for melted wires or burnt prongs. Finally, a drive motor with internal shorts can trip the breaker and will show abnormal continuity on a motor test. Enter your model number on RepairClinic.com to find the exact replacement heating element, power cord, motor, or other parts that fit your dryer.

01 - The Circuit Breaker is Weak

Over time, circuit breakers can weaken. If the circuit breaker is weak, it may trip, even if the amperage draw from the dryer is below the breakers limit. If you have already checked all of the potentially defective dryer components, consider having an electrician replace the circuit breaker.
Top Solution

02 - Inglis Dryer Heating Element

Sometimes, if the heating element fails, it shorts out against the heater housing, causing the dryer to trip the circuit breaker. To determine if the heating element is at fault, use a multimeter to test each terminal for continuity to the case. If the heating element has continuity to the case, it is shorted out. If the heating element is shorted out, replace it.
Enter model number to search for the required part specific to your product
Top Solution

03 - Inglis Dryer Heating Element Assembly

Sometimes, if the heating element fails, it shorts out against the heater housing, causing the dryer to trip the circuit breaker. To determine if the heating element assembly is shorted out, use a multimeter to test each terminal for continuity to the case. If the heating element assembly has continuity to the case, it is shorted out. If the heating element assembly is shorted out, replace it.
Top Solution

04 - Inglis Dryer Power Cord

If the dryer's power cord wire terminal connections are not secured properly to the terminal block, the terminal block can short out and cause a circuit breaker to trip or a fuse to blow. You should inspect both the terminal block and the power cord terminal connections for damage. If the power cord wire terminals are burnt or melted, you will need to replace the power cord.
Highly Likely

05 - Loose or Burnt Power Cord Connections

Loose or burnt power cord connections can cause restricted current flow, making the circuit breaker overheat and trip. Shut off power to the dryer, then check the power cord connections and receptacle for burnt prongs, wires, or terminals. If the power cord or terminal block is damaged it will need to be replaced.
Common

06 - Inglis Dryer Drive Motor

Sometimes, when the drive motor fails, it shorts out internally, causing the dryer to trip the circuit breaker. To determine if the drive motor is at fault, use a multimeter to test it for continuity. If the motor windings are shorted out, replace the drive motor.
Common

Frequently Asked Questions

Why does my dryer keep tripping the circuit breaker?
Can a shorted heating element cause the dryer to trip the breaker?
Could a bad power cord or loose terminal block make the dryer trip the breaker?
How do I test the drive motor if I suspect it's tripping the breaker?
How do I enter my model number or part number on RepairClinic.com to find the right replacement part?