If your Sanyo microwave is making a loud noise, rumbling, squealing, grinding, or buzzing, start with the fan motor. Worn fan motor bearings commonly cause noise while the microwave runs, and the motor should be replaced if the sound comes from it. A damaged magnetron is the next likely cause, especially when you hear a high-pitched sound or growling instead of the normal low hum. A failing high-voltage diode can also make the magnetron noisy, so test the diode before replacing the magnetron. Other possible causes include a defective exhaust fan motor, worn glass tray support rollers, or a failing stirrer motor. Check whether the exhaust fan blades turn freely and whether the glass tray support or stirrer is the source of the sound. For any repair that requires removing the outer cabinet, remember that the high-voltage capacitor can store a lethal charge even after the microwave is unplugged. The capacitor must be properly discharged before interior work, and repairs involving the magnetron or high-voltage diode may require a qualified technician if you are not familiar with safe discharge procedures. Enter your Sanyo microwave model number to find the exact replacement part for your appliance.
01 - Sanyo Microwave Fan Motor
The fan motor bearings can wear out causing a rumbling or squealing noise. If the fan motor is making noise when its running it will need to be replaced.
Enter model number to search for the required part specific to your product
The magnetron uses high voltage, high current DC power to generate the microwave frequency that cooks the food. Under normal circumstances, the magnetron emits a low hum. However, if the magnetron is damaged or nearly burned out, it may begin emitting high-pitched sounds or growling noises. If the magnetron is noisy, this indicates that the magnetron is nearing the end of its life or might be defective. A defective high-voltage diode can also cause the magnetron to be loud. Before replacing the magnetron, first test the high voltage diode. If the diode is not defective, replace the magnetron. (Warning: The microwave oven c...an store a lethal amount of electricity in its high voltage capacitor, even after the microwave oven has been unplugged. Due to the high running voltage and the potential for electric shock, it is extremely dangerous to replace the electronic components in a microwave. Only a licensed technician should replace the magnetron.)
The diode converts the AC power output of the transformer to DC, doubling the voltage to nearly 5,000 volts. This high voltage powers the magnetron to heat the food. A failing diode can be responsible for a noisy magnetron. When the diode fails, it is often visibly burned out. Inspect the diode and if the diode is burned out, replace it. If inspecting the diode proves inconclusive, test it with a multimeter that uses a 9-volt battery or put a 9-volt battery in series with the diode. When the leads are reversed, the diode should only have continuity in one direction.
To determine if the fan motor is defective, remove the fan motor from the microwave and try turning the fan blades by hand. If the blades do not turn freely, replace the fan motor. If the fan blades do turn freely, use a multimeter to test the motor for incoming power and for continuity. If the motor has power but won’t run, replace it. If the motor does not have continuity, replace it.
The microwave glass tray support is the component that sits under the glass turntable tray to support the tray as it rotates. Over time, the small rollers on the support can wear out and start making a noise as the tray turns. If you've determined the glass tray support is the source of the noise, the part should be replaced with a new one.
The stirrer is a metal blade which slowly rotates inside in the microwave. As the stirrer turns, it deflects the microwave energy randomly throughout the microwave. As the stirrer motor wears down, it begins to make grinding noises. To determine if the stirrer motor is worn out, check to see if voltage is getting to the motor. If the motor has the proper voltage, but is noisy or won’t turn, replace it. (Note: Proper voltage can be determined by reading the label on the motor. Because the stirrer motor is a geared motor, the shaft will not spin freely.)