Roper Gas stove burners spark all the time

If your Roper gas stove igniter keeps clicking or the gas stove keeps sparking after the burner lights, a defective spark ignition switch is the most likely cause. Test each switch with a multimeter for continuity. A switch that shows continuity at every dial setting is stuck closed and should be replaced. The spark ignition switch and harness can also be wet or shorted, especially after a boil-over, so unplug the range and let the stovetop dry completely before testing. Next, inspect the surface burner orifice holder. If it is misaligned, it may not ground correctly, preventing the spark module from sensing the flame. Make sure each burner cap is seated properly on its burner base, since a misplaced cap can keep gas or flame away from the spark electrode. If the burner still won't stop sparking, inspect the spark electrode for dirt or visible damage. A faulty electrode may fail to sense the flame even when the burner is lit. Enter your Roper range model number to find the exact spark ignition switch, harness, or spark electrode replacement part for your appliance.

01 - Roper Range/Stove/Oven Spark Ignition Switch

One of the spark ignition switches might be defective. The spark ignition switch sends voltage to the spark module. When the electrical contacts inside the switch close, power flows to the spark module. If the spark ignition switch fails with the electrical contacts closed, the switch will send continuous voltage to the spark module. To determine if any of the spark ignition switches is defective, use a multimeter to test each of the switches for continuity. If a spark ignition switches shows continuity at all settings, replace it.
Enter model number to search for the required part specific to your product
Top Solution

02 - Roper Range/Stove/Oven Spark Ignition Switch and Harness

One of the spark ignition switches might be defective. The spark ignition switch sends voltage to the spark module. When the electrical contacts inside the switch close, power flows to the spark module. If the switch contacts are wet or stuck in a closed position, the switch will send continuous voltage to the spark module, no matter where the dial is set. Each of the switches can be tested individually to determine if they are shorted. If a spark ignition switch is shorted and is not wet, or if drying it out doesn’t solve the problem, replace the switch.
Top Solution

03 - Roper Range/Stove/Oven Surface Burner Orifice Holder

Some burners have a flame sensing circuit that sense the burner flame through the spark electrode circuit. If the burner has a good flame but the igniter keeps sparking the orifice holder may not be damaged and not grounding properly. Inspect the holder to see if it's misaligned and replace with a new one as required.
Top Solution

04 - Burner cap not on properly

On some models the spark module will automatically shut off the spark when the burner lights. If the burner cap is not on properly the gas or flame may not get to the igniter causing continuous sparking. Confirm the appliance is turned off and the stovetop is cool to the touch, then readjust the burner cap, if necessary, so it is seated properly on the burner base.
Top Solution

05 - Water spilt on switches

The spark switches under the burner knobs have to be dry to work properly. If water boils over or is spilt on the spark switches, they can short out, causing the burners to spark even when the switch is turned off. The range should be unplugged and the stovetop allowed a day to dry out.
Common

06 - Roper Range/Stove/Oven Spark Electrode

The range's spark module sends pulses to each spark electrode to create a spark to ignite the gas. If the spark module has a flame sensing function it will automatically stop sending pulses to the electrode when the burner lights. If the electrode is defective the spark module will not be able to sense the flame and continue to allow the electrode to spark after the flame has ignited. Inspect the electrode to see if it's visibly damaged or dirty and replace if necessary.