Maytag Range vent hood doesn't vent to the outside
When your Maytag range vent hood doesn't vent to the outside, start by checking whether the blower motor and fan blade are running when the hood is turned on. If the fan blade does not spin, verify that the blower motor is receiving power, then test the switch for continuity. A motor that has power but will not turn is defective and should be replaced. Next, inspect the blower wheel and housing. The blower wheel may be blocked by grease or debris, or it may be rubbing against the housing. Turn the wheel by hand. It should spin freely. If it does not, clear the obstruction or replace the blower wheel and housing or blower wheel. Also check whether the fan blade is loose on the motor shaft, and tighten or replace it if needed. A clogged grease filter can restrict airflow even when the fan runs. Clean the filter with degreaser and warm, soapy water, or replace it if damaged. Enter your Maytag range vent hood model number to find the exact blower motor, fan blade, blower wheel, housing, or grease filter for your appliance.
01 - Maytag Range Vent Hood Blower Motor
To determine if the blower motor is defective, turn on the vent hood and check to see if the fan blade is spinning. If the fan blade does not spin, ensure that power is getting to the motor. If power is not getting to the motor, test the switch for continuity. If the motor is receiving power, but the motor won’t turn, replace the blower motor.
Enter model number to search for the required part specific to your product
02 - Maytag Range Vent Hood Blower Wheel and Housing
One possibility is that something is caught in the blower wheel. It is also possible that the blower wheel is rubbing against the blower housing. To determine if the blower wheel is at fault, try spinning the blower fan by hand. If the blower wheel does not spin freely, check for the blower wheel for obstructions. In addition, ensure that the blower wheel is not rubbing against the blower housing. If the blower wheel is clear of obstructions, but it still doesn’t spin freely, replace the blower wheel and housing.
One possibility is that something is caught in the blower wheel. It is also possible that the blower wheel is rubbing against the blower housing. To determine if the blower wheel is at fault, try spinning the blower fan by hand. If the blower wheel does not spin freely, check for the blower wheel for obstructions. In addition, ensure that the blower wheel is not rubbing against the blower housing. If the blower wheel is clear of obstructions, but it still doesn’t spin freely, replace the blower wheel.
Check to see if the fan blade is still tightly fastened to the motor shaft. If the blade is loose, try to tighten it. If the blade cannot be properly tightened, replace it.
If the range hood is not venting correctly, the grease filter(s) may be clogged. If a filter is very dirty it can be cleaned. Remove it and soak it in a degreasing solution until the grease is dissolved. Next, wash it with warm, soapy water to remove any traces of the degreaser. If the filter does not come clean or is damaged, replace it.
Highly Likely
06 - Maytag Range Vent Hood Grease Filter
If the range hood is not venting correctly check out the grease filter(s). If the filter is very dirty it can be cleaned. Remove it and soak it in a degreasing solution until the grease is dissolved. Next, wash it with warm, soapy water to remove any traces of the degreaser. If the filter does not come clean or is damaged, replace it.