Bosch Refrigerator has frost or ice buildup

If your Bosch refrigerator has frost or ice buildup, the usual culprits are components that control or fail to run the defrost cycle. Start by checking the defrost control board, but first test the defrost heater and defrost thermostat—if those parts work and frost keeps accumulating, the control board is likely at fault. A worn defrost timer is the next suspect; advance it into the defrost position and watch for the compressor to stop and the heater to come on. A stuck or noisy evaporator fan motor can also let cold air sit and freeze the defrost drain, so spin the blade by hand and test the motor for continuity. Missing drain straps or a clogged defrost drain make ice buildup worse, and in some cases a defective water inlet valve can contribute to overflow and extra freezing around the ice maker. These are common causes of a refrigerator not defrosting or a defrost drain clogged problem, and RepairClinic has the parts and guides to help you test and replace them. Enter your model number on RepairClinic.com to find the exact replacement part for your refrigerator.

01 - Bosch Refrigerator Defrost Control Board

The defrost control board determines how often to run the defrost cycle. If the board fails, the refrigerator will not go into the defrost cycle. Before replacing the defrost control board, first test the defrost heater and defrost thermostat. If the defrost heater and defrost thermostat are working properly, the defrost control board is likely defective.
Enter model number to search for the required part specific to your product
Top Solution

02 - Bosch Refrigerator Defrost Timer

The defrost timer turns on the defrost heater several times throughout the day to melt any frost that may have accumulated on the evaporator coils. If the defrost timer is defective, it may not advance into the defrost cycle, or it may not send power to the defrost heater during the defrost cycle. To determine if the defrost timer is defective, slowly advance the dial into the defrost cycle. The compressor should turn off and the heater should turn on. If the timer does not send power to the defrost components or advance out of the defrost cycle within 30 minutes, this indicates that the defrost timer is not advancing. If ...the defrost timer is not advancing, replace it.
Top Solution

03 - Bosch Refrigerator Water Inlet Valve

The water inlet valve requires a minimum of 20 psi to shut off properly. If the water pressure is too low, the valve may not close fully once the power is shut off. As a result, the valve will leak water into the ice maker and cause the ice maker to overflow. Check the water pressure to determine if it is at least 20 psi. If the water pressure is sufficient, the water inlet valve is likely defective. The valve may not shut off all the way or may be stuck open, causing water to leak through the valve. If the water pressure is sufficient, but the ice maker is still overflowing, replace the water inlet valve.
Top Solution

04 - Bosch Refrigerator Fan Motor

If the refrigerator's defrost drain is clogged, it's possible the evaporator fan motor is not working. If the evaporator fan is not running, cold air from the evaporator can migrate to the defrost drain causing ice buildup in the drain. To determine if the evaporator fan motor is defective, try turning the fan blade by hand. If the fan blade does not turn freely, replace the fan motor. Additionally, if the motor is unusually noisy, replace it. Finally, if the motor does not run at all, use a multimeter to test the motor windings for continuity. If the windings do not have continuity, replace the evaporator fan motor.
Top Solution

05 - Bosch Refrigerator Drain Strap

Some defrost drains are outfitted with a drain strap. The drain strap is a small piece of copper or aluminum that attaches to the defrost heater and extends partway into the defrost drain. When the defrost heater turns on, heat is conducted through the drain strap to melt away any ice that may have accumulated further down in the defrost drain. If the drain strap is not in place, the defrost drain may be more likely to freeze over.
Top Solution

06 - Bosch Refrigerator Evaporator Fan Motor

If the refrigerator's defrost drain is clogged, it's possible the evaporator fan motor is not working. If the evaporator fan is not running, cold air from the evaporator can migrate to the defrost drain causing ice buildup in the drain. To determine if the evaporator fan motor is defective, try turning the fan blade by hand. If the fan blade does not turn freely, replace the fan motor. Additionally, if the motor is unusually noisy, replace it. Finally, if the motor does not run at all, use a multimeter to test the motor windings for continuity. If the windings do not have continuity, replace the evaporator fan motor.
Top Solution

Frequently Asked Questions

Why is my fridge not cooling but the freezer is cold?
How can I tell if the defrost drain is clogged and how do I fix it?
My ice maker is overflowing with water. What should I check?
Refrigerator not defrosting: which parts should I test first?
How do I enter my model number or part number on RepairClinic.com to find the correct replacement?

Shop by Bosch Refrigerator Parts