Hardwick Refrigerator has frost or ice buildup

If your Hardwick refrigerator has frost or ice buildup, the most common culprits are problems in the defrost system rather than a mystery leak. Start by checking the defrost control board. If the refrigerator is not defrosting and the defrost heater and defrost thermostat test good, the control board is likely defective. The next most likely cause is a faulty defrost timer that will not advance or send power to the heater. A sticking water inlet valve can overfill the ice maker and create ice buildup, and a clogged defrost drain will let melt water pool and freeze where it should flow away. An evaporator fan motor that does not run can make drain freeze worse, and some models use a drain strap that conducts heat into the drain so a missing strap can allow re-freezing. Test heaters, thermostats, timers and fan motors for continuity and try advancing the timer before buying parts. Enter your model number on RepairClinic.com to find the exact replacement part for your refrigerator.

01 - Hardwick Refrigerator Defrost Control Board

The defrost control board determines how often to run the defrost cycle. If the board fails, the refrigerator will not go into the defrost cycle. Before replacing the defrost control board, first test the defrost heater and defrost thermostat. If the defrost heater and defrost thermostat are working properly, the defrost control board is likely defective.
Enter model number to search for the required part specific to your product
Top Solution

02 - Hardwick Refrigerator Defrost Timer

The defrost timer turns on the defrost heater several times throughout the day to melt any frost that may have accumulated on the evaporator coils. If the defrost timer is defective, it may not advance into the defrost cycle, or it may not send power to the defrost heater during the defrost cycle. To determine if the defrost timer is defective, slowly advance the dial into the defrost cycle. The compressor should turn off and the heater should turn on. If the timer does not send power to the defrost components or advance out of the defrost cycle within 30 minutes, this indicates that the defrost timer is not advancing. If ...the defrost timer is not advancing, replace it.
Top Solution

03 - Hardwick Refrigerator Water Inlet Valve

The water inlet valve requires a minimum of 20 psi to shut off properly. If the water pressure is too low, the valve may not close fully once the power is shut off. As a result, the valve will leak water into the ice maker and cause the ice maker to overflow. Check the water pressure to determine if it is at least 20 psi. If the water pressure is sufficient, the water inlet valve is likely defective. The valve may not shut off all the way or may be stuck open, causing water to leak through the valve. If the water pressure is sufficient, but the ice maker is still overflowing, replace the water inlet valve.
Top Solution

04 - Hardwick Refrigerator Fan Motor

If the refrigerator's defrost drain is clogged, it's possible the evaporator fan motor is not working. If the evaporator fan is not running, cold air from the evaporator can migrate to the defrost drain causing ice buildup in the drain. To determine if the evaporator fan motor is defective, try turning the fan blade by hand. If the fan blade does not turn freely, replace the fan motor. Additionally, if the motor is unusually noisy, replace it. Finally, if the motor does not run at all, use a multimeter to test the motor windings for continuity. If the windings do not have continuity, replace the evaporator fan motor.
Top Solution

05 - Hardwick Refrigerator Drain Strap

Some defrost drains are outfitted with a drain strap. The drain strap is a small piece of copper or aluminum that attaches to the defrost heater and extends partway into the defrost drain. When the defrost heater turns on, heat is conducted through the drain strap to melt away any ice that may have accumulated further down in the defrost drain. If the drain strap is not in place, the defrost drain may be more likely to freeze over.
Top Solution

06 - Hardwick Refrigerator Evaporator Fan Motor

If the refrigerator's defrost drain is clogged, it's possible the evaporator fan motor is not working. If the evaporator fan is not running, cold air from the evaporator can migrate to the defrost drain causing ice buildup in the drain. To determine if the evaporator fan motor is defective, try turning the fan blade by hand. If the fan blade does not turn freely, replace the fan motor. Additionally, if the motor is unusually noisy, replace it. Finally, if the motor does not run at all, use a multimeter to test the motor windings for continuity. If the windings do not have continuity, replace the evaporator fan motor.
Top Solution

Frequently Asked Questions

Why is my refrigerator not defrosting and forming frost or ice buildup?