Gibson Refrigerator has frost or ice buildup

If your Gibson refrigerator has frost or ice buildup, the most likely cause is a defrost system failure preventing the unit from going into its defrost cycle. Start by testing the defrost heater and defrost thermostat, since a bad defrost control board is the top culprit when those parts check good. Next suspect the defrost timer if the compressor keeps running or the heater never gets power; manually advancing the timer should shut the compressor off and power the heater for a quick check. Less commonly, a faulty water inlet valve can cause ice or overflow problems around the ice maker. Also check the evaporator fan motor and any drain strap, because a seized fan or missing drain strap lets cold air or trapped ice form in the drain and create a defrost drain clogged condition. Try turning the fan blade by hand and use a multimeter for winding continuity if it won’t run. Enter your model number on RepairClinic.com to find the exact replacement parts for your refrigerator and follow step-by-step guides for each test and repair.

01 - Gibson Refrigerator Defrost Control Board

The defrost control board determines how often to run the defrost cycle. If the board fails, the refrigerator will not go into the defrost cycle. Before replacing the defrost control board, first test the defrost heater and defrost thermostat. If the defrost heater and defrost thermostat are working properly, the defrost control board is likely defective.
Enter model number to search for the required part specific to your product
Top Solution

02 - Gibson Refrigerator Defrost Timer

The defrost timer turns on the defrost heater several times throughout the day to melt any frost that may have accumulated on the evaporator coils. If the defrost timer is defective, it may not advance into the defrost cycle, or it may not send power to the defrost heater during the defrost cycle. To determine if the defrost timer is defective, slowly advance the dial into the defrost cycle. The compressor should turn off and the heater should turn on. If the timer does not send power to the defrost components or advance out of the defrost cycle within 30 minutes, this indicates that the defrost timer is not advancing. If ...the defrost timer is not advancing, replace it.
Top Solution

03 - Gibson Refrigerator Water Inlet Valve

The water inlet valve requires a minimum of 20 psi to shut off properly. If the water pressure is too low, the valve may not close fully once the power is shut off. As a result, the valve will leak water into the ice maker and cause the ice maker to overflow. Check the water pressure to determine if it is at least 20 psi. If the water pressure is sufficient, the water inlet valve is likely defective. The valve may not shut off all the way or may be stuck open, causing water to leak through the valve. If the water pressure is sufficient, but the ice maker is still overflowing, replace the water inlet valve.
Top Solution

04 - Gibson Refrigerator Fan Motor

If the refrigerator's defrost drain is clogged, it's possible the evaporator fan motor is not working. If the evaporator fan is not running, cold air from the evaporator can migrate to the defrost drain causing ice buildup in the drain. To determine if the evaporator fan motor is defective, try turning the fan blade by hand. If the fan blade does not turn freely, replace the fan motor. Additionally, if the motor is unusually noisy, replace it. Finally, if the motor does not run at all, use a multimeter to test the motor windings for continuity. If the windings do not have continuity, replace the evaporator fan motor.
Top Solution

05 - Gibson Refrigerator Drain Strap

Some defrost drains are outfitted with a drain strap. The drain strap is a small piece of copper or aluminum that attaches to the defrost heater and extends partway into the defrost drain. When the defrost heater turns on, heat is conducted through the drain strap to melt away any ice that may have accumulated further down in the defrost drain. If the drain strap is not in place, the defrost drain may be more likely to freeze over.
Top Solution

06 - Gibson Refrigerator Evaporator Fan Motor

If the refrigerator's defrost drain is clogged, it's possible the evaporator fan motor is not working. If the evaporator fan is not running, cold air from the evaporator can migrate to the defrost drain causing ice buildup in the drain. To determine if the evaporator fan motor is defective, try turning the fan blade by hand. If the fan blade does not turn freely, replace the fan motor. Additionally, if the motor is unusually noisy, replace it. Finally, if the motor does not run at all, use a multimeter to test the motor windings for continuity. If the windings do not have continuity, replace the evaporator fan motor.
Top Solution

Frequently Asked Questions

Why is my refrigerator not defrosting?
My defrost drain is clogged. How do I clear a clogged defrost drain?
Freezer cold but fridge warm — could frost or a bad fan cause that?
Ice maker overflowing with water — what should I check?
How do I enter my model number to find the right replacement part on RepairClinic.com?

Shop by Gibson Refrigerator Parts