If your Hotpoint refrigerator is building up frost or ice, the most likely causes are a failed defrost control board or a defrost timer that never advances, both of which stop the heater from melting frost on the evaporator coils. Before replacing the control board, test the defrost heater and defrost thermostat; if those parts are good, the board is the usual culprit. Less commonly, a leaking water inlet valve or a stuck-open valve can flood the ice maker or drain area and contribute to freezing. A failing evaporator or fan motor can also let cold air collect around the defrost drain, causing a clogged defrost drain and ice buildup farther down the drain tube. Missing drain straps that conduct heat into the drain can make the problem worse. Repair Clinic has step-by-step diagnostics and replacement parts for each of these components; enter your model number on RepairClinic.com to see the exact replacement parts that fit your refrigerator and get the right parts fast.
01 - Hotpoint Refrigerator Defrost Control Board
The defrost control board determines how often to run the defrost cycle. If the board fails, the refrigerator will not go into the defrost cycle. Before replacing the defrost control board, first test the defrost heater and defrost thermostat. If the defrost heater and defrost thermostat are working properly, the defrost control board is likely defective.
Enter model number to search for the required part specific to your product
The defrost timer turns on the defrost heater several times throughout the day to melt any frost that may have accumulated on the evaporator coils. If the defrost timer is defective, it may not advance into the defrost cycle, or it may not send power to the defrost heater during the defrost cycle. To determine if the defrost timer is defective, slowly advance the dial into the defrost cycle. The compressor should turn off and the heater should turn on. If the timer does not send power to the defrost components or advance out of the defrost cycle within 30 minutes, this indicates that the defrost timer is not advancing. If ...the defrost timer is not advancing, replace it.
The water inlet valve requires a minimum of 20 psi to shut off properly. If the water pressure is too low, the valve may not close fully once the power is shut off. As a result, the valve will leak water into the ice maker and cause the ice maker to overflow. Check the water pressure to determine if it is at least 20 psi. If the water pressure is sufficient, the water inlet valve is likely defective. The valve may not shut off all the way or may be stuck open, causing water to leak through the valve. If the water pressure is sufficient, but the ice maker is still overflowing, replace the water inlet valve.
If the refrigerator's defrost drain is clogged, it's possible the evaporator fan motor is not working. If the evaporator fan is not running, cold air from the evaporator can migrate to the defrost drain causing ice buildup in the drain. To determine if the evaporator fan motor is defective, try turning the fan blade by hand. If the fan blade does not turn freely, replace the fan motor. Additionally, if the motor is unusually noisy, replace it. Finally, if the motor does not run at all, use a multimeter to test the motor windings for continuity. If the windings do not have continuity, replace the evaporator fan motor.
Some defrost drains are outfitted with a drain strap. The drain strap is a small piece of copper or aluminum that attaches to the defrost heater and extends partway into the defrost drain. When the defrost heater turns on, heat is conducted through the drain strap to melt away any ice that may have accumulated further down in the defrost drain. If the drain strap is not in place, the defrost drain may be more likely to freeze over.
If the refrigerator's defrost drain is clogged, it's possible the evaporator fan motor is not working. If the evaporator fan is not running, cold air from the evaporator can migrate to the defrost drain causing ice buildup in the drain. To determine if the evaporator fan motor is defective, try turning the fan blade by hand. If the fan blade does not turn freely, replace the fan motor. Additionally, if the motor is unusually noisy, replace it. Finally, if the motor does not run at all, use a multimeter to test the motor windings for continuity. If the windings do not have continuity, replace the evaporator fan motor.