Choose Product
Identify Problem
03
Find Solutions

Kelvinator Refrigerator not running

If your Kelvinator refrigerator is not running and the display or dispenser controls look dead, start with the parts and power issues that cause this most often. A failed dispenser control board is a top suspect when the display is black or unresponsive, so inspect the board for burn marks and replace it if damaged. Next check incoming power: make sure the plug is fully seated, the outlet is supplying power and no breakers or fuses have tripped; avoid using a GFCI for long term refrigerator use. The user control and display board is another common failure, followed by loose or damaged wire harness connectors between the panel and control board. Simple power resets after a surge or outage can restore operation, and only after you test those items should you consider replacing the main control board, which is less commonly the root cause. If you need the right part, enter your model number at RepairClinic.com to find the exact replacement for your refrigerator control panel not working, refrigerator display not working, or other refrigerator control board troubleshooting needs.

01 - Kelvinator Refrigerator Dispenser Control Board

If the refrigerator display appears completely dead, it's possible the dispenser control board has failed. You should inspect the board for any burn marks and replace it if it appears damaged.
Enter model number to search for the required part specific to your product
Highly Likely

02 - Incoming Power Problem

Ensure plug is tightly pushed into a regular electrical outlet and the outlet is supplying power. Using a ground fault outlet for a refrigerator is not recommended. Confirm that no circuit breakers have tripped or fuses have blown.
Highly Likely

03 - Kelvinator Refrigerator User Control and Display Board

If the refrigerator display appears completely dead, it's possible the user control and display board has failed. You should inspect the board for any burn marks and replace it if it appears damaged.
Common

04 - Disconnected or Damaged Wire Harness

The wires from the control panel to the control board may be loose or have become disconnected. Make sure the wire harness connectors are tight. A damaged wire harness will need to be replaced.
Common

05 - Power reset

After a power surge or power outage, refrigerator operation could be temporarily affected. Full operation can sometimes be restored through a power reset by either unplugging the appliance's power cord for a few minutes and then plugging it back in or switching off the circuit breaker for the refrigerator then switching it back on.
Common

06 - Kelvinator Refrigerator Control Board

If nothing is working on the refrigerator, it's likely the control board is defective. However, this is almost never the cause. Before replacing the main control board, test all of more commonly defective parts. If none of the other components are defective, consider replacing the control board.
Less Common

Frequently Asked Questions

My refrigerator control panel is dead. What should I check first?
Fridge stopped running after a power outage or surge. Will a power reset fix it?
How can I tell if the main control board is bad or if another part is the problem?
How do I check a disconnected or damaged wire harness?
How do I use my model number or part number on RepairClinic.com to find the right replacement part?

Shop by Kelvinator Refrigerator Parts