Choose Product
Identify Problem
03
Find Solutions

Dacor Refrigerator not cooling

If your Dacor refrigerator is not cooling, start with the basics: dirty condenser coils under the unit are the single most common cause and should be cleaned every 6 to 12 months so the compressor can do its job. Next check the temperature settings — freezer should be 0 to 5°F and the fridge 34 to 40°F — then give the condenser fan motor a look; if it won’t spin or is noisy it won’t move air across the coils. If the freezer is cold but the fridge is warm, the evaporator fan motor or airflow between compartments is often at fault. Also inspect the door gasket for gaps that let warm air in, and confirm the outlet, breaker and power supply are solid. If you need parts, enter your model number on RepairClinic.com to find the exact replacement condenser fan, evaporator fan, gasket or other parts for your refrigerator not cooling problem. These checks will diagnose most fridge not cooling or refrigerator not getting cold issues and point you to the right repair.

01 - Condenser Coils are Dirty

As debris builds up on the condenser coils, usually located under the refrigerator, the appliance will become less efficient and will have to cycle on more often to maintain a cool temperature. If the condenser coils are significantly clogged with debris, the compressor may overheat and shut off prematurely, preventing the appliance from cooling at all. The condenser coils should be cleaned every 6 to 12 months by using a soft bristle brush (or a dedicated condenser coil cleaning brush) to wipe off the coils in a circular motion. A vacuum cleaner with a nozzle attachment can also be used for hard-to-reach areas.
Top Solution

02 - Freezer or refrigerator temperature is set too high

Verify the freezer temperature is set between 0 and 5 degrees Fahrenheit (-18 to -15 Celsius). Verify the refrigerator temperature is set between 34 and 40 degrees Fahrenheit (1 to 5 Celsius). After resetting the temperature wait 24 hours for the temperature to adjust appropriately.
Top Solution

03 - Dacor Refrigerator Condenser Fan Motor

The condenser fan motor draws air though the condenser coils and over the compressor. If the condenser fan motor is not working properly, the refrigerator won’t cool properly. To determine if the fan motor is defective, first check the fan blade for obstructions. Next, try turning the fan motor blade by hand. If the blade does not spin freely, replace the condenser fan motor. If no obstructions are present and the fan blade spins freely, use a multimeter to test the fan motor for continuity. If the condenser fan motor does not have continuity, replace it.
Enter model number to search for the required part specific to your product
Top Solution

04 - Dacor Refrigerator Evaporator Fan Motor

The evaporator fan motor draws air over the evaporator (cooling) coils and circulates it throughout the refrigerator and freezer compartments. Some refrigerators have more than one evaporator fan motor. On refrigerators with only one evaporator, the evaporator is located in the freezer compartment. If the evaporator fan is not working, it will not circulate the cold air to the refrigerator compartment. If this occurs, the freezer may still get cold, while the refrigerator will not get cold. To determine if the evaporator fan motor is defective, try turning the fan blade by hand. If the fan blade does not turn freely, repla...ce the fan motor. Additionally, if the motor is unusually noisy, replace it. Finally, if the motor does not run at all, use a multimeter to test the motor windings for continuity. If the windings do not have continuity, replace the evaporator fan motor.
Highly Likely

05 - Dacor Refrigerator Door Gasket

A refrigerator door gasket should form an airtight seal around the appliance's frame to keep the cold air in and the warm air out. If the door gasket is twisted or torn, gaps can form that will allow warm air in, resulting in the refrigerator not cooling properly. Inspect the door gasket for any damage and replace with a new one if necessary.
Highly Likely

06 - Incoming Power Problem

Ensure plug is tightly pushed into a regular electrical outlet and the outlet is supplying power. Using a ground fault outlet for a refrigerator is not recommended. Confirm that no circuit breakers have tripped or fuses have blown.
Highly Likely

Frequently Asked Questions

Why is my fridge not cooling but the freezer is cold?
Can dirty condenser coils cause my refrigerator not cooling?
How do I know if the condenser fan motor or evaporator fan motor needs replacement?
My refrigerator runs constantly. What should I check?
How do I enter my model number or part number on RepairClinic.com to find the correct replacement part?