Choose Product
Identify Problem
03
Find Solutions

U-Line Refrigerator is noisy or loud

If your U-Line refrigerator is noisy or loud, start with the simple stuff: the most common culprits are the evaporator or condenser fan blades — check the freezer back panel and the condenser under the unit and spin the blades by hand; if they scrape, have debris caught, or rub a housing they’ll make the fridge making noise you hear. Next likely is low water pressure causing the inlet valve to squeal or chatter, so check kitchen faucet flow to rule that out. A failing evaporator fan motor often gets much louder when the door opens and should be replaced if noisy. Worn damper control assemblies can make snapping or grinding sounds as they open and close, and an unlevel refrigerator will vibrate or rattle, so level the cabinet. Less commonly, the ice maker’s drive motor or module may be failing and produce loud cycling noises. If you need a part, enter your model number on RepairClinic.com to find the exact replacement part for your refrigerator and get step-by-step repair help.

01 - U-Line Refrigerator Fan Blade

If the refrigerator is noisy or loud, especially when one of the doors are opened, either the evaporator or condenser fan blade may be at fault. First, check out the evaporator fan blade in the freezer behind the back panel. Try turning it by hand. If the fan blade does not turn freely, check to see if the blade is rubbing against something or if something is caught in the blade. Additionally, check the condenser fan blade in the back underside of the refrigerator to determine if it has any obstructions.
Enter model number to search for the required part specific to your product
Highly Likely

02 - Low Water Pressure from House Supply

The home may have insufficient water pressure. The water inlet valve supplies water to the ice maker and low water pressure may cause the inlet valve to squeal or chatter. You can check the water flow at the kitchen faucet to help determine if the home's water pressure is sufficient or not.
Highly Likely

03 - U-Line Refrigerator Evaporator Fan Motor

When the evaporator fan motor in the freezer behind the rear panel fails, it often generates a lot of noise. This noise will be much louder when the refrigerator door is opened. If the evaporator fan is noisy, replace it.
Highly Likely

04 - U-Line Refrigerator Damper Control Assembly

On many refrigerator models, a damper control assembly is used to control the air flow from the freezer compartment to the refrigerator compartment to maintain the appropriate air temperature. The assembly accomplishes this by opening and closing a small door. As the damper control assembly ages, the action of opening and closing the damper door can become noisy or loud. If the damper control assembly has become increasing noisy, you can replace the old assembly with a new one.
Highly Likely

05 - Refrigerator not level

If the refrigerator is not level it can vibrate or rattle. Ensure the unit is level and stable on the floor. Most refrigerators' front legs or rollers are adjustable.
Highly Likely

06 - U-Line Refrigerator Ice Maker Assembly

If a refrigerator is making a loud noise near the ice maker when the unit is cycling, it's likely that either the ice maker's drive motor or motor module is beginning to fail. While some of the ice maker components, such as the drive motor or module, may be sold separately for select models, you may need to purchase and replace the entire ice maker assembly.
Common

Frequently Asked Questions

Why is my refrigerator making a loud noise when I open the door?
My fridge is noisy all the time, not just when the door opens. What should I check?
I hear a high-pitched squeal around the ice maker or water line. Could that be the water inlet valve?
How can I tell if the damper control assembly or the evaporator fan motor is the noisy part?
How do I use my model number on RepairClinic.com to find the correct replacement part?