HomePartsLuxaire PartsLuxaire Furnace Parts

Luxaire Furnace Parts

Browse genuine OEM Luxaire Furnace Parts, including igniters, flame sensors, control boards, and blower motors, to help restore heat and reliable operation. Get the right part for your model with same-day shipping on in-stock parts, expert repair help, a price match guarantee, and 365-day returns.

Find the right part faster

Multiple models matched. Select your model to confirm fit.

1,916 results for 
Luxaire
Furnace
Sort:
Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a bestsellerProduct is a manufacturer part
S1-03103010000 Control Board
$172.89

Furnace control board. The control board regulates the supply of power to the furnace components.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-02532625000 Igniter
$84.39

Furnace hot surface igniter kit. The igniter gets very hot and glows bright orange to light the gas burner. If the igniter is cracked or defective, the furnace won’t heat.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-02527773700 Flame Sensor
$39.60

Furnace flame sensor. The flame sensor monitors the burner to detect whether or not a flame is present. If the flame sensor is defective, the furnace may not heat.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-02537499000 Flame Sensor
$71.91

Furnace flame sensor. The flame sensor monitors the burner to detect whether or not a flame is present. If the flame sensor is defective, the furnace may not heat.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-02420045700 Run Capacitor
$13.07

Genteq Run Capacitor 370 Volt Oval Single 7.5 MFD

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-02442415000 Contactor
$48.50

Contactor with shunt, 1 pole, 30 amps, 24 volts

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a bestsellerProduct is a manufacturer part
S1-02440901000 Blower Motor
$361.36

Furnace blower motor. This single-phase motor has the following specifications:

Horsepower: 1/2
Voltage: 115
Full-Load Amperage: 7.7
Hertz: 60
RPM: 1175
Speeds: 4
Rotation: Counterclockwise
Frame: 48
Enclosure: Open

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-S90-380 Relay
$31.17

Fan relay, 24v coil, 50-60hz, spst-no/nc

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-02649692000 Draft Inducer Motor
$273.58

Furnace draft inducer motor. The draft inducer motor draws air into the burner and exhausts it out the flue. If the draft inducer motor is defective, the furnace may not heat.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-02435329000 Draft Inducer Motor
$363.21

Draft inducer blower assembly. 60 Hz 1.75 Amps, 3000 RPM.The draft inducer blower draws air into the burner and exhausts it out the flue. If the draft inducer motor is defective, the furnace may not heat.

Go
Find. Fix. Finish.
Whether you're a pro or a novice, we've got you covered with the repair know-how and replacement Luxaire Furnace parts you need.
Genuine OEM Parts Supplier
Genuine OEM Luxaire Replacement Parts
Get peace of mind with the real thing—genuine OEM Luxaire Furnace parts.
365-Day Appliance Parts Return Policy
No-Hassle 365-Day Returns
Return uninstalled Luxaire Furnace parts and products for any reason within 365 days of purchase.
Same day shipping
Same-Day Shipping
Get the job finished. Order replacement Luxaire Furnace parts by 9:00 PM ET, and we'll ship them the same day.
Price Match Guarantee For Appliance Parts
Price Match Guarantee
We'll match any price offered by our direct competitors on all genuine OEM Luxaire Furnace replacement parts
Genuine OEM Parts Supplier
Genuine OEM Luxaire Replacement Parts
Get peace of mind with the real thing—genuine OEM Luxaire Furnace parts.

Luxaire Furnace Parts You Need to Get Heat Back

Luxaire furnaces are built on York engineering — reliable, long-lasting equipment that's installed in thousands of homes. When your Luxaire furnace stops heating or won't ignite, the fix is usually one of a handful of high-failure parts. Hot surface igniters, draft inducer motors, and pressure switches account for the majority of Luxaire furnace repairs. We stock genuine OEM Luxaire parts for every model, with same-day shipping on most orders.

Finding the exact part for your Luxaire model is straightforward when you use your model number. Whether you need an igniter assembly, limit switch, flame sensor, or control board, Repair Clinic has the OEM part in stock and ready to ship. Luxaire shares its platform with York and other Johnson Controls brands, but always verify your specific model number to ensure compatibility.

  • Hot surface igniter won't glow or glows then goes dark: The igniter is wearing out. Verify the igniter type (silicon carbide or silicon nitride) for your model — they're not interchangeable.
  • Furnace won't start or pressure switch keeps tripping: The draft inducer motor or pressure switch has failed. A blocked vent line is the first thing to check, but if the vent is clear, replace the inducer or switch.
  • Furnace ignites then shuts down within seconds: A cracked or dirty flame sensor is the usual culprit. Try cleaning it first with fine steel wool; if that doesn't work, replace it.
  • No response from the thermostat or error codes on the control board: The main control board (CNT or similar) has failed. OEM boards come pre-programmed for your model and are required for communicating systems.
  • Blower runs but produces no heat: The limit switch may have tripped from overheating, or the gas valve has failed. Check the heat exchanger for blockage first.

Find Replacement Luxaire Furnace Parts Online by Model or Part Number


Popular Luxaire Furnace Models

Luxaire Furnace Parts: Answers to Your Questions

Why is my Luxaire furnace igniter so important?

The hot surface igniter is the part that glows red-hot to ignite the gas in your furnace. When it weakens — usually after 5 to 10 years of use — it either won't glow at all or glows but can't maintain heat long enough to trigger the gas valve. Replacing it is one of the most common and effective Luxaire furnace repairs. Always check your model number to confirm whether you need a silicon carbide (SiC) or silicon nitride (SiN) igniter, as the two types have different electrical properties and are not interchangeable.

What does the draft inducer motor do, and when should I replace it?

The draft inducer motor runs first in every heating cycle to create a slight vacuum in the furnace and vent pipe, which pulls in fresh air and exhausts combustion gases safely out of your home. If you hear rattling, grinding, or a high-pitched squeal from the furnace, or if your pressure switch keeps tripping without an obvious blockage, the inducer motor has likely failed. The motor is sold as an assembly with the impeller wheel, so you replace the whole unit. This is a straightforward job that restores proper operation and safety to your furnace.

How do I find my Luxaire furnace model number?

Your Luxaire model number is on a metal plate attached to the furnace cabinet, usually on the front or side near the burner compartment. It starts with letters like "XC" or "XR" followed by numbers. Write down the complete model number — it's needed for ordering the correct parts. You can also look inside the furnace cabinet or check your original installation paperwork. Once you have the model number, enter it into our parts finder tool and we'll show you every compatible part for your system, including igniters, motors, switches, and boards.

Can I use aftermarket parts on my Luxaire furnace?

OEM Luxaire parts are designed and tested for your specific model and are always the safest choice. Control boards, gas valves, and igniters in particular are engineered to exact specifications. Aftermarket parts may fit physically but often don't meet the electrical or pressure specifications your furnace needs, which can trigger safety shutdowns or poor performance. Repair Clinic stocks genuine OEM parts from Luxaire and carries a broad range of models, so you're getting the right part the first time — not a generic substitute.

Homeowner with safety glasses and electrical gloves on inspects a furnace HVAC system with a flashlight to troubleshoot the problem
Amana furnace replacement parts ready for HVAC installation

Order Luxaire Furnace Replacement Parts Online

Ordering Luxaire furnace replacement parts online is simple with Repair Clinic. You can easily search by model number or part number to find the specific parts you need. Our full inventory of Luxaire parts includes everything from blower motors to thermostats, helping you maintain your furnace's efficiency. Whether you need a replacement gas valve, flame sensor, or air filter, we have you covered with genuine OEM parts designed for your Luxaire furnace.

With Repair Clinic's No-Hassle 365-Day Returns, you can return uninstalled parts within a year of purchase, ensuring peace of mind with every purchase. Take advantage of our Price Match Guarantee to rest assured you're getting competitive pricing on high-quality Luxaire parts. We also offer same-day shipping on orders placed by 9:00 PM ET, so you can get the parts you need as quickly as possible.

Whether you're a homeowner tackling a DIY furnace repair or a professional technician working on Luxaire systems, Our online repair library provides the videos, guides, and diagrams to support the repair. Browse our large inventory of Luxaire furnace parts and get your furnace back up and running efficiently.

Luxaire Furnace Model Number: Where to Look

On Luxaire furnaces, look for the model number on the metal nameplate attached to the cabinet, often on the side panel or near the burner compartment. You may need to remove the front access panel to see it clearly. Record the complete model number, including letters and numbers, rather than relying on the serial number or a shortened label. Type it into our model number lookup and the catalog narrows to parts made for your unit, across every furnace part category. This quick check helps match parts such as igniters, blower motors, switches, valves, and control boards to the entire furnace, so you avoid compatibility guesswork and get the repair moving.

Background Image

Online Repair Library for Luxaire Furnace

Repair Clinic's online repair library gives you the tools to diagnose and fix your Luxaire Furnace without a service call. Common-symptom articles cover the most likely causes, part testing videos confirm the failed component, and step-by-step written guides walk you through the installation. Use the model number lookup to confirm the exact OEM part, and exploded-view diagrams and wiring illustrations support the more involved jobs.

Related Furnace Repair Help Articles

How To Replace a Circuit Board in Your Furnace

How To Replace a Circuit Board in Your Furnace

Microwave sparking is often caused by food residue, a damaged waveguide cover, or a faulty diode. Identifying and fixing the issue quickly can prevent further damage and ensure safe operation.

Why is My Furnace Not Working?

Why is My Furnace Not Working?

Learn why your furnace isn't working by understanding its ignition sequence and identifying common faulty parts like the igniter, flame sensor, or control board. This article provides practical repair tips and insights into each part's role in the heating process.

5 Causes of a Furnace Starting Then Stopping

5 Causes of a Furnace Starting Then Stopping

A gas furnace that starts and then stops unexpectedly can be frustrating, especially during cold weather. This article explains five common causes, including issues with the flame sensor, pressure switch, control board, draft inducer fan motor, or air flow. Learn how each cause may impact your furnace's operation and get tips to resolve the problem.