Furnace flame sensor with wire harness

Furnace flame sensor. The flame sensor monitors the burner to detect whether or not a flame is present. If the flame sensor is defective, the furnace may not heat.

Pressure switch -0.20"pf spst

Furnace draft inducer motor. The draft inducer motor draws air into the burner and exhausts it out the flue. If the draft inducer motor is defective, the furnace may not heat.

Furnace igniter kit

Limit Switch - re-settable

Run Capacitor, Single, Round, 370 Volts 10 Microfarads

Furnace control board. The control board regulates the supply of power to the furnace components. Be sure to check more commonly defective parts before replacing the control board.

Replacement filter, large

Limit Switch

Pressure switch. NO, 1.74C

Rollout switch

Furnace igniter kit

Furnace control board. The control board regulates the supply of power to the furnace components. Be sure to check more commonly defective parts before replacing the control board.

Run capacitor, round, 7.5 MFD, 370 volts
Tappan furnaces are built tough, but when they fail, you need the right OEM parts fast. Whether your Tappan gas furnace won't ignite, won't heat, or trips the pressure switch constantly, we carry the exact parts that restore it to full operation.
The most common Tappan furnace repairs involve hot surface igniters, draft inducer motors, pressure switches, and flame sensors. These parts are inexpensive compared to a service call, and many are DIY-friendly. Verify your model number on the furnace nameplate to ensure exact compatibility — Tappan is part of the Nordyne family, and model variations matter.
The hot surface igniter is the #1 Tappan furnace failure. When the igniter glows orange but the gas valve won't open, or it doesn't glow at all, you've found your culprit. It's a $30 to $60 OEM part and a straightforward 20-minute replacement. Silicon carbide igniters are the standard type for most Tappan models, but verify yours before ordering — some older units use different types.
The model number is stamped on the rating nameplate, which is usually mounted on the side or front of the furnace cabinet. It will look something like TPAB or TPBA followed by numbers. Write down the complete model and serial number, then enter both into the Repair Clinic model lookup tool. This ensures you get parts that fit your exact furnace configuration — igniter type, blower motor voltage, and control board all depend on the model.
Yes — Tappan, Intertherm, Miller, Gibson, and Frigidaire (HVAC) are all Nordyne brands and share many parts. However, some parts are model-specific, especially control boards and igniters. Always verify compatibility using your exact model number. The pressure switch, limit switch, inducer motor, and gas valve often cross-reference between Nordyne brands, but don't assume — confirm in the parts diagram for your model.
Not always. The pressure switch is a safety device that monitors airflow. Before replacing the switch, check for a blocked drain hose (condensation backup), a clogged inducer wheel (lint/dust buildup), or a cracked hose connection. Clean or clear these first. If the switch still trips after airflow is confirmed, the switch itself has failed and needs replacement. A new pressure switch is $20 to $40 and takes 10 minutes to swap.


With Repair Clinic, ordering genuine Tappan furnace replacement parts is both convenient and reliable. Our extensive inventory includes everything from flame sensors and igniters to control boards and pressure switches, ensuring you find the exact part needed for your gas, electric, or oil furnace. Take advantage of our No-Hassle 365-Day Returns, allowing you to return uninstalled parts for any reason within a year of purchase. Plus, our Price Match Guarantee helps you shop with confidence on genuine OEM parts. Easily locate the right parts by entering your furnace's model or part number in our search tool, and enjoy same-day shipping if you order by 9:00 PM ET Trust Repair Clinic to support your DIY repairs with our comprehensive support and competitive pricing.
On Tappan furnaces, look for the model number on the rating nameplate mounted on the side or front of the cabinet, often near the access panels. The label may also list the serial number, so copy the complete model number exactly, including letters, numbers, and hyphens. Use it in the model number search to pull up the parts matched to your unit. This filters Repair Clinic's full Tappan furnace parts catalog, not just one category, so igniters, sensors, motors, controls, and other parts shown apply to your specific furnace model. That means fewer wrong orders and a faster repair.

The online repair library at Repair Clinic covers Tappan Furnace diagnostics, part testing, and installation from start to finish. Symptom-based articles narrow the failing component, and matching repair videos or step-by-step written guides walk you through the fix. Use the model number lookup to confirm the exact OEM part before you order, then follow the exploded-view diagrams for a clean reassembly.

A furnace that fails to ignite can leave your home in the cold. Common issues include a faulty igniter, malfunctioning flame sensor, or a defective draft inducer fan motor. Replacing furnace filters and cleaning furnace parts can help prevent these problems.

Learn why your furnace isn't working by understanding its ignition sequence and identifying common faulty parts like the igniter, flame sensor, or control board. This article provides practical repair tips and insights into each part's role in the heating process.

A gas furnace that starts and then stops unexpectedly can be frustrating, especially during cold weather. This article explains five common causes, including issues with the flame sensor, pressure switch, control board, draft inducer fan motor, or air flow. Learn how each cause may impact your furnace's operation and get tips to resolve the problem.