1/10HP 208-230Volts 60Hertz 0.7Amps 1100RPM Single Speed Closed Enclosure 42Y Frame Single Phase CW Rotation 1.5" Shaft

Fan motor, 208/230Volts 60Hertz 1.15/1.18Amps 1075RPM Single Speed Closed Enclosure 42Y Frame Single Phase CW Rotation 2.25" Shaft

Condenser Fan Motor

1/4 HP 208-230Volts 60Hertz 1.4Amps 1075RPM Single Speed Closed Enclosure Single Phase CW Rotation 1.5" Shaft

Condenser fan motor, 1/4 HP, 208-230 volts, 60 Hertz, 1.4 amps, 825 RPM, single speed closed enclosure, 48Y, frame single phase CW rotation, 2" shaft

Condenser fan motor, 1/4 HP, 208-230 volts, 60 hertz, 1.2 amps, 1100 RPM, Single Speed, Closed Enclosure, 48Y Frame, Single Phase CW Rotation 2.5" Shaft

Condenser fan motor

Condenser motor 1100 rpm, 1/4 hp (230v)

1/8 HP 208-230Volts 60Hertz 1 Amp 1100RPM Single Speed Closed Enclosure Single Phase CCW Rotation 3.25" Shaft

Condenser fan motor, 1/8 HP, 1100 RPM, 208/230 volts

Motor blower 1/3 hp 208/230v 1050rpm

Fru, mtr, prog, dm2xf, 1/2hp, 10x10, p3/q3rd

Motor, fan 1/4 hp 460v

Repl, mtr, dm2rf, bomc, 1/3 hp, df

Repl, restrictor (.077 )
Gibson air conditioners—part of the Nordyne family—rely on robust motors and electrical parts to keep cooling systems running smoothly. When your unit stops cycling on, hums without starting, or runs but won't cool, motor-related parts are often the culprit. Capacitors fail most frequently, leaving your compressor and condenser fan unable to start. Condenser fan motors wear out from constant outdoor exposure, reducing airflow and causing the system to overheat and shut down.
Repair Clinic stocks genuine Gibson replacement parts backed by manufacturer specs and our 365-day returns help ensure. Find your exact model number on the nameplate near the condenser unit or indoor coil, then browse motor assemblies, capacitors, and starter parts below. Our expert parts team is ready to help you identify the right replacement for your Gibson AC system.
A failed run capacitor is the most common cause. The capacitor provides the electrical boost needed to start your compressor and condenser fan motor. When it fails, you'll hear a hum from the outdoor unit but no actual cooling. Check your model number on the condenser nameplate and compare the microfarad (µF) rating on your old capacitor to find the exact replacement.
Your model number is stamped on the nameplate attached to the side or back of your outdoor condenser unit. It typically starts with a letter code like "GC" or "GN" followed by numbers. Write down the complete model and serial number—this ensures you get parts engineered for your specific unit, especially important in the Nordyne family where Intertherm, Miller, and Gibson models share platforms but have different electrical specifications.
Run capacitors stay energized while the motor operates and are rated for continuous duty. Start capacitors provide a temporary boost only during startup, then disconnect. Gibson systems typically use dual-run capacitors (two in one housing) for the compressor and fan motor. A failed run capacitor won't damage your motor immediately, but running without it forces the motor to draw excessive current and overheat.
It depends on the failure. If only the motor itself has burned out (you'll smell burning or see scorch marks), you can often replace the motor alone. However, if the fan blades are cracked, bent, or the motor shaft is damaged, replacing the entire condenser fan motor assembly is safer and more cost-effective. Repair Clinic stocks both individual motors and complete assemblies for Gibson units in the Nordyne ecosystem.


When it comes to maintaining your Gibson Central Air Conditioner, sourcing the right motor parts is essential. Our full inventory of genuine replacement parts ensures your system operates smoothly. Use the model or part number lookup for a precise match, making it effortless to find compatible parts. Take advantage of same-day shipping to reduce downtime and get your air conditioner back up and running quickly. The No-Hassle 365-Day Returns policy and Price Match Guarantee make it even easier Keep your HVAC system in top condition by visiting our Gibson Central Air Conditioner Parts page for more options. For expansive support, access the Central Air Conditioner Repair Help section, where you'll find guides and tips for common repair challenges, ensuring your home stays comfortable all year round.
On Gibson central air conditioners, look for the model number on the exterior nameplate attached to the side or back of the outdoor condenser. Some systems also list it on a label inside the indoor access panel, so check both areas if needed. Copy the complete model number carefully, including letters and numbers, then type it into the model number search to pull up the parts matched to your unit. The model number filters the full Gibson central air conditioner catalog, not just motor parts, so you can review every associated part that fits your specific system. You will spend less time comparing specifications and more time making an accurate repair.

Diagnosing a Gibson problem is easier when you have the right online reference material. Repair Clinic's video library, written repair guides, symptom articles, part testing walkthroughs, and exploded-view diagrams work together to guide you from the symptom to the correct part. Model number lookup confirms the exact OEM replacement so you order right the first time.

Learn how to troubleshoot a broken central air conditioner and which key parts to check to restore proper cooling.

Pinpoint five common reasons your dishwasher is making noise and learn how to address each issue for quieter, more efficient operation.

Find out why your gas oven is not heating up and which key parts to check to restore proper cooking performance.