Repl, control, blwr-cfm, dm2f
Grid is 1 inch square
  Control Board 922016
Manufacturer Part

Control Board 922016

Genuine OEM Part # 922016RC Item # 3307223Alternative Part Number(s)
Manufacturer Part
Repl, control, blwr-cfm, dm2f
Grid is 1 inch square
  Control Board 922016
$693.15
Loading stock status
Loading stock status
Does this part fit my product?
Find your model number or log in to select it from your saved machines.
Repl, control, blwr-cfm, dm2f
Loading stock status
$693.15
start a live chat with Repair Clinic customer support

This part 922016 is compatible with:

Product Type:
Furnace
Brands:
Frigidaire, Maytag, Gibson, Kelvinator, Tappan, White-Westinghouse, Nordyne, Garrison, Intertherm, Mammoth, Medallion, Philco, GrandAire, Miller

Related Articles & Videos

01:52
Troubleshooting
Furnace Blower Runs All The Time — Furnace Troubleshooting
02:28
Troubleshooting
Furnace Blower Not Running — Furnace Troubleshooting
00:45
Troubleshooting
Replace Furnace Filters - Tech Tips from Repair Clinic
02:47
Troubleshooting
Furnace Starts Then Stops — Furnace Troubleshooting
03:52
Troubleshooting
Furnace Not Heating — Furnace Troubleshooting

Control Board Customer Reviews

Common Problems Fixed by the Control Board

Based on customer reports and repair data, this part commonly fixes these issues:

Very Likely

Furnace blower runs all the time

Very Likely

Furnace takes too long to heat the home

Likely

Furnace burners won't stay lit

Likely

Air handler blower not running/not turning on

Likely

Air handler not heating

Likely

Furnace blower not running

Likely

Furnace not turning on

Likely

Furnace not heating

Possible

Furnace starts then stops

Possible

Air handler blower runs all the time

Possible

Air handler has a burning smell

Possible

Air handler not cooling properly

Possible

Furnace blower is running constantly but there is no heat

Possible

Strange smells coming from furnace

Possible

Furnace is frequently cycling/short cycling

Possible

Air handler wall thermostat not working properly

Possible

Furnace circuit breaker keeps tripping

Possible

Furnace wall thermostat not working properly

Possible

Air handler is frequently cycling/short cycling

Possible

Air handler circuit breaker keeps tripping

About the Control Board

The control board has relays that regulate the voltage to each component in the furnace. If the relay that controls the blower motor fails while it is closed, it will send continuous voltage to the blower motor, causing the motor to run continuously. If the control board is at fault, replace it.

Alternative Part Number(s)

Replaces Part Number 624757
Replaces Part Number 624757R
Replaces Part Number 624807