Type: Shaded Pole; Diameter: 3.3"; HP: 1/50; Volts: 115; RPM: 3000; Speeds: 1; Amps: 1.1; Rotation: Clockwise; Bearings: Sleeve. The draft inducer motor draws air into the burner and exhausts it out the flue. If the draft inducer motor is defective, the furnace may not heat.
Grid is 1 inch square
Fasco Furnace Draft Inducer Motor A090
Fasco Furnace Draft Inducer Motor A090
Fasco Furnace Draft Inducer Motor A090
Fasco Furnace Draft Inducer Motor A090

Fasco Furnace Draft Inducer Motor A090

Genuine OEM Part # A090RC Item # 2332824Alternative Part Number(s)
Type: Shaded Pole; Diameter: 3.3"; HP: 1/50; Volts: 115; RPM: 3000; Speeds: 1; Amps: 1.1; Rotation: Clockwise; Bearings: Sleeve. The draft inducer motor draws air into the burner and exhausts it out the flue. If the draft inducer motor is defective, the furnace may not heat.
Grid is 1 inch square
Fasco Furnace Draft Inducer Motor A090
Fasco Furnace Draft Inducer Motor A090
Fasco Furnace Draft Inducer Motor A090
Fasco Furnace Draft Inducer Motor A090
$305.24
Loading stock status
Loading stock status
Does this part fit my product?
Find your model number or log in to select it from your saved machines.
Type: Shaded Pole; Diameter: 3.3"; HP: 1/50; Volts: 115; RPM: 3000; Speeds: 1; Amps: 1.1; Rotation: Clockwise; Bearings: Sleeve. The draft inducer motor draws air into the burner and exhausts it out the flue. If the draft inducer motor is defective, the furnace may not heat.
Loading stock status
$305.24
start a live chat with Repair Clinic customer support

This part A090 is compatible with:

Product Type:
Furnace
Brands:
Fasco

Related Articles & Videos

04:29
How This Part Works
Furnace Draft Inducer Fan Motor Replacement
03:52
Troubleshooting
Furnace Not Heating — Furnace Troubleshooting
01:49
Troubleshooting
Furnace Noisy Or Loud — Furnace Troubleshooting
00:45
Troubleshooting
Replace Furnace Filters - Tech Tips from Repair Clinic
02:47
Troubleshooting
Furnace Starts Then Stops — Furnace Troubleshooting
Frequently Bought with Draft Inducer Motor
LH680534 Flame Sensor
5303935066 Igniter
HH18HA493 Limit Switch
S1-03103010000 Control Board
Recommended Tools & Accessories
93247 Silicone Sealant

Draft Inducer Motor Customer Reviews

Common Problems Fixed by the Draft Inducer Motor

Based on customer reports and repair data, this part commonly fixes these issues:

About the Draft Inducer Motor

The draft inducer motor draws air into the heat exchanger and then exhausts it out the flue. The pressure switch senses a pressure change and closes a switch to signal the control board that the furnace has proper air flow. If the draft inducer motor is defective, it may be unable to close the pressure switch, causing the ignition process to stall and the furnace to shut off after a few minutes. If the ignition process stalls, the furnace will shut off. If the draft inducer motor is at fault, replace it.

Shop by Brands

Repair Help by Brands and Product Type

Alternative Part Number(s)

Replaces Part Number A090
Part Production Number 7002-2558
Part Production Number 7021-10268
Part Production Number 7021-5239
Part Production Number 7021-5615
Part Production Number 7021-5715
Part Production Number 7021-8013
Part Production Number 7021-8693
Part Production Number 7021-8788
Part Production Number 7062-3861
Part Production Number 7062-4537
Part Production Number 7062-4699
Part Production Number 7062-4841
Part Production Number 7062-5177
Part Production Number 7062-5615