Type: Shaded Pole; HP: 1/20; Volts: 230; RPM: 1500; Speeds: 1; Amps: 0.9; Enclosure: Open Vent.; Rotation: Counter Clockwise; Bearings: Sleeve; Shaft: 5/16 X 2 1/4"; "A" Dimension (inches): 2 7/8"
Grid is 1 inch square
Fasco Draft Inducer Motor D189
Fasco Draft Inducer Motor D189
Fasco Draft Inducer Motor D189
Fasco Draft Inducer Motor D189

Fasco Draft Inducer Motor D189

Genuine OEM Part # D189RC Item # 2333889Alternative Part Number(s)
Type: Shaded Pole; HP: 1/20; Volts: 230; RPM: 1500; Speeds: 1; Amps: 0.9; Enclosure: Open Vent.; Rotation: Counter Clockwise; Bearings: Sleeve; Shaft: 5/16 X 2 1/4"; "A" Dimension (inches): 2 7/8"
Grid is 1 inch square
Fasco Draft Inducer Motor D189
Fasco Draft Inducer Motor D189
Fasco Draft Inducer Motor D189
Fasco Draft Inducer Motor D189
$109.76
Loading stock status
Loading stock status
Does this part fit my product?
Find your model number or log in to select it from your saved machines.
Type: Shaded Pole; HP: 1/20; Volts: 230; RPM: 1500; Speeds: 1; Amps: 0.9; Enclosure: Open Vent.; Rotation: Counter Clockwise; Bearings: Sleeve; Shaft: 5/16 X 2 1/4"; "A" Dimension (inches): 2 7/8"
Loading stock status
$109.76
start a live chat with Repair Clinic customer support

This part D189 is compatible with:

Product Type:
Furnace
Brands:
Fasco

Related Articles & Videos

04:29
How This Part Works
Furnace Draft Inducer Fan Motor Replacement
03:52
Troubleshooting
Furnace Not Heating — Furnace Troubleshooting
01:49
Troubleshooting
Furnace Noisy Or Loud — Furnace Troubleshooting
00:45
Troubleshooting
Replace Furnace Filters - Tech Tips from Repair Clinic
02:47
Troubleshooting
Furnace Starts Then Stops — Furnace Troubleshooting
Frequently Bought with Draft Inducer Motor
LH680534 Flame Sensor
5303935066 Igniter
HH18HA493 Limit Switch
S1-03103010000 Control Board

Draft Inducer Motor Customer Reviews

Common Problems Fixed by the Draft Inducer Motor

Based on customer reports and repair data, this part commonly fixes these issues:

About the Draft Inducer Motor

The draft inducer motor draws air into the heat exchanger and then exhausts it out the flue. The pressure switch senses a pressure change and closes a switch to signal the control board that the furnace has proper air flow. If the draft inducer motor is defective, it may be unable to close the pressure switch, causing the ignition process to stall and the furnace to shut off after a few minutes. If the ignition process stalls, the furnace will shut off. If the draft inducer motor is at fault, replace it.

Shop by Brands

Repair Help by Brands and Product Type

Alternative Part Number(s)

Replaces Part Number D189