Ensure accurate water levels with this pressure switch, part number HK06MB061, for select Carrier, Bryant, or Payne Furnace, Packaged Unit/RTU, Heat Pump, or Air Handler models.
Grid is 1 inch square
  Pressure Switch HK06MB061
  Pressure Switch HK06MB061
  Pressure Switch HK06MB061
Manufacturer Part

Pressure Switch HK06MB061

Genuine OEM Part # HK06MB061RC Item # 4985908Alternative Part Number(s)
Manufacturer Part
Ensure accurate water levels with this pressure switch, part number HK06MB061, for select Carrier, Bryant, or Payne Furnace, Packaged Unit/RTU, Heat Pump, or Air Handler models.
Grid is 1 inch square
  Pressure Switch HK06MB061
  Pressure Switch HK06MB061
  Pressure Switch HK06MB061
$46.16
Loading stock status
Loading stock status
Does this part fit my product?
Find your model number or log in to select it from your saved machines.
Ensure accurate water levels with this pressure switch, part number HK06MB061, for select Carrier, Bryant, or Payne Furnace, Packaged Unit/RTU, Heat Pump, or Air Handler models.
Loading stock status
$46.16
start a live chat with Repair Clinic customer support

This part HK06MB061 is compatible with:

Product Type:
Furnace
Brands:
Carrier, Bryant, Payne

Related Articles & Videos

03:01
How This Part Works
Furnace Pressure Switch Replacement
00:45
Troubleshooting
Replace Furnace Filters - Tech Tips from Repair Clinic
02:47
Troubleshooting
Furnace Starts Then Stops — Furnace Troubleshooting
03:52
Troubleshooting
Furnace Not Heating — Furnace Troubleshooting
02:28
Troubleshooting
Furnace Blower Not Running — Furnace Troubleshooting

Pressure Switch Customer Reviews

Common Problems Fixed by the Pressure Switch

Based on customer reports and repair data, this part commonly fixes these issues:

Likely

Furnace takes too long to heat the home

Likely

Furnace burners won't stay lit

Possible

Furnace starts then stops

Possible

Heat pump not cooling

Possible

Heat pump not heating

Possible

Heat pump compressor won't run

Possible

Furnace is frequently cycling/short cycling

Possible

Furnace not heating

Possible

Air handler not cooling properly

About the Pressure Switch

The pressure switch closes when the burner has sufficient airflow. If the pressure switch isn’t working, it might not close when the proper airflow is present, resulting in the furnace taking too long to heat the home. If the ignition process stalls, the furnace will shut off. To determine if the pressure switch is defective, use a multimeter to test the switch for continuity. If the pressure switch does not have continuity, replace it.