Reverse refrigerant with this replacement reversing valve, part number EF17BZ251, built for select Carrier, Bryant, or Payne Furnace, Packaged Unit/RTU, Heat Pump, or Central Air Conditioners.
Grid is 1 inch square
  Reversing Valve EF17BZ251
  Reversing Valve EF17BZ251
Manufacturer Part

Reversing Valve EF17BZ251

Genuine OEM Part # EF17BZ251RC Item # 2377278
Manufacturer Part
Reverse refrigerant with this replacement reversing valve, part number EF17BZ251, built for select Carrier, Bryant, or Payne Furnace, Packaged Unit/RTU, Heat Pump, or Central Air Conditioners.
Grid is 1 inch square
  Reversing Valve EF17BZ251
  Reversing Valve EF17BZ251
$212.70
Loading stock status
Loading stock status
Does this part fit my product?
Find your model number or log in to select it from your saved machines.
Reverse refrigerant with this replacement reversing valve, part number EF17BZ251, built for select Carrier, Bryant, or Payne Furnace, Packaged Unit/RTU, Heat Pump, or Central Air Conditioners.
Loading stock status
$212.70
start a live chat with Repair Clinic customer support

This part EF17BZ251 is compatible with:

Product Type:
Central Air Conditioner, Furnace
Brands:
Carrier, Bryant, Payne

Related Articles & Videos

00:45
Troubleshooting
Replace Furnace Filters - Tech Tips from Repair Clinic
02:47
Troubleshooting
Furnace Starts Then Stops — Furnace Troubleshooting
02:01
Troubleshooting
Central Air Conditioner Fan Motor Not Running — Central Air Conditioner Troubleshooting
03:12
Troubleshooting
Central Air Conditioner Not Cooling — Central Air Conditioner Troubleshooting
01:47
Troubleshooting
Central Air Conditioner Is Noisy — Central Air Conditioner Troubleshooting
Frequently Bought with Reversing Valve
LH680534 Flame Sensor
5303935066 Igniter
HH18HA493 Limit Switch
S1-03103010000 Control Board

Reversing Valve Customer Reviews

Common Problems Fixed by the Reversing Valve

Based on customer reports and repair data, this part commonly fixes these issues:

Likely

Heat pump not heating

Possible

Heat pump not cooling

About the Reversing Valve

Heat pumps have a reversing valve that can reverse the direction of the refrigerant through the condenser and evaporator coils when heat is required. This will effectively make the condensing coils behave like an evaporator, and the evaporator coils behave like a condenser. The heat that is dissipated when the unit is in its cooling mode will, instead, be used to warm the air in the room. If the reversing valve is faulty and unable to reverse the direction of the refrigerant, the unit may be unable to heat.