Bryant 310AAV036070ACJA Parts

Shop replacement repair parts for Bryant Furnace model 310AAV036070ACJA

icons/furnace
Brand:Bryant
Model:310AAV036070ACJA
Product:Furnace
87 results
Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a bestsellerProduct is a manufacturer part
LH680534 Flame Sensor
$51.99

Furnace flame sensor. The flame sensor monitors the burner to detect whether or not a flame is present. If the flame sensor is defective, the furnace may not heat.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a bestsellerProduct is a manufacturer part
349336-761 Draft Inducer Motor
$323.14

The 349336-761 Draft Inducer Motor is essential for enhancing the efficiency of your furnace's ventilation system. To prevent carbon monoxide from leaking into your home, we recommend replacing the draft inducer gasket or using high-temp silicone sealant when servicing the motor or inducer fan.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
KA56GR560 Grommet
$15.82

Furnace draft inducer mounting grommet. This grommet helps isolate the blower assembly from the furnace to reduce noise.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
LA660003 Fan Blade
$14.19

Furnace draft inducer motor cooling fan blade and clip. You may have to cut the old clip off to remove the fan blade.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a bestsellerProduct is a manufacturer part
HK42FZ034 Control Board
$519.65

Carrier furnace control board, The control board regulates the supply of power to the furnace components. Be sure to check more commonly defective parts before replacing the control board.

Go

Bryant 310AAV036070ACJA Problems & Repair Solutions

There are only a handful of issues that crop up with most appliances and equipment. Since 1912, we've learned to recognize the most common Bryant 310AAV036070ACJA problems ― and their solutions. Do any of these look familiar?
Furnace not heating
31 possible causes and potential solutions
Furnace not heating
Furnace is noisy or loud
15 possible causes and potential solutions
Furnace is noisy or loud
Furnace starts then stops
16 possible causes and potential solutions
Furnace starts then stops

Frequently Purchased Together For This Model

Flame Sensor
Flame Rollout Limit Switch
Igniter
Draft Inducer Motor

Keep your Bryant 310AAV036070ACJA furnace performing dependably with genuine OEM replacement parts from Repair Clinic. The 310AAV036070ACJA is a Bryant 80% AFUE upflow gas furnace; the 036 in the model number identifies the cabinet width class and the 070 designates 70,000 BTU input capacity. Bryant and Carrier are sister brands under Carrier Global, sharing the same manufacturing platform with fully interchangeable service components at equivalent configurations; Payne is also a Carrier Global brand on the same platform. Parts most frequently replaced include the inducer motor, blower motor, flame sensor, igniter, and control board. Use the 310AAV036070ACJA parts list and browse the full Bryant furnace parts catalog.

Bryant 310AAV036070ACJA: 70,000 BTU 80% AFUE Upflow Platform and Carrier Sister Brand Equivalence

The Bryant 310AAV036070ACJA is an 80% AFUE non-condensing upflow gas furnace using standard metal B-vent exhaust, with no condensate management or PVC venting. The 310AAV series uses a PSC blower motor and a single-stage gas valve, making it a straightforward service platform. Because Bryant and Carrier are sister brands under Carrier Global, the 310AAV036070ACJA and the equivalent Carrier furnace at the same configuration use identical components including the inducer motor, blower motor, igniter, flame sensor, and control board. Reading the control board’s LED fault code blink pattern is the correct first diagnostic step before replacing any component; the code printed on the furnace’s lower access panel interior identifies which stage of the ignition sequence has failed. For diagnostic guidance, visit the Bryant furnace repair help section.

Common Bryant 310AAV036070ACJA Replacement Parts

Bryant 310AAV036070ACJA Inducer Motor

The inducer motor draws combustion gases through the heat exchanger and exhausts them through the B-vent before ignition begins. A slow-running or stalled inducer reduces the negative pressure the pressure switch monitors; when the switch fails to close, the furnace locks out before the igniter energizes. Grinding at inducer startup indicates bearing failure and warrants proactive replacement before the motor seizes. Browse Bryant furnace inducer motor parts.

Bryant 310AAV036070ACJA Blower Motor

The PSC blower motor circulates conditioned air through the supply duct system after each heating cycle. Weak airflow at registers and repeated high-limit trips indicate blower motor performance below rated speed. Test the blower run capacitor before ordering a blower motor replacement; a capacitor outside its rated microfarad range produces identical slow-running symptoms at a fraction of the motor replacement cost. Browse Bryant furnace blower motor parts.

Bryant 310AAV036070ACJA Flame Sensor

The flame sensor is a single-rod ionization probe that confirms burner ignition within seconds of the gas valve opening. Carbon and oxide buildup on the rod reduces its conductivity; when the signal drops below the board’s minimum threshold, the gas valve closes and the furnace short-cycles through three attempts before hard lockout. Cleaning the rod extends its service life, but a rod with visible pitting or glazing requires replacement. Browse Bryant furnace flame sensor parts.

Bryant 310AAV036070ACJA Igniter

The hot surface igniter is a silicon carbide element that fractures along stress lines after thousands of heat cycles. A cracked igniter may glow adequately at room temperature but fail to reach ignition temperature when cold air flows across it, resulting in a no-fire condition while the inducer and pressure switch operate normally. Replace the igniter when any visible crack is present. Browse Bryant furnace igniter parts.

Bryant 310AAV036070ACJA Control Board

The control board manages the complete heat cycle and reports faults through a diagnostic LED blink code. Note the blink count and match it to the fault chart on the lower access panel before replacing any component. A board that appears dead may simply be receiving no 24-volt power from a failed transformer; confirm input voltage before condemning the board. Browse Bryant furnace control board parts.

Bryant 310AAV036070ACJA Parts at Repair Clinic

  • Genuine Bryant OEM Parts for the 310AAV 70,000 BTU Platform: Every 310AAV036070ACJA part meets original equipment specifications, with Carrier and Payne cross-reference as sister brands under Carrier Global. Browse the full Bryant furnace parts catalog.
  • Bryant-Carrier Sister Brand Equivalence: The 310AAV036070ACJA and its Carrier equivalent at the same configuration share identical components; parts are cross-catalogued between both brand designations.
  • Fault Code Diagnostic Priority: Our content documents reading the 310AAV control board LED blink count before replacing any component to identify the specific failed stage of the ignition sequence.
  • 365-Day Returns and Fast Shipping: In-stock 310AAV036070ACJA parts ship promptly. The Bryant furnace repair help section provides step-by-step diagnostic guidance.

Bryant 310AAV036070ACJA Furnace Parts FAQ

Why is my Bryant 310AAV036070ACJA furnace not heating?

Read the control board LED fault code blink pattern first; the code identifies the specific stage of the ignition sequence that has failed. Common causes of no-heat on the 310AAV036070ACJA are a cracked igniter, a dirty flame sensor, or a failed pressure switch preventing draft confirmation. The LED blink count directs the diagnosis before any component is replaced.

What does the inducer motor do in a Bryant 310AAV furnace?

The inducer motor draws combustion gases through the heat exchanger and exhausts them through the B-vent before ignition begins. It also creates the negative pressure the pressure switch monitors before allowing ignition to proceed. A slow-running inducer produces pressure switch faults even when the switch itself tests functional; confirm inducer speed before replacing the pressure switch.

Why is my Bryant 310AAV036070ACJA not blowing warm air?

Weak or no airflow with burners firing typically indicates a blower motor running below rated speed due to a failed run capacitor, or a high-limit switch tripping from restricted airflow. Test the blower run capacitor before ordering a motor replacement; a capacitor outside its rated microfarad range is the lower-cost fix and resolves the majority of these complaints.

Are Bryant 310AAV036070ACJA parts interchangeable with Carrier furnace parts?

Yes. Bryant and Carrier are sister brands under Carrier Global sharing the same manufacturing platform. The 310AAV036070ACJA and the equivalent Carrier furnace at the same configuration use identical inducer motors, blower motors, igniters, flame sensors, and control boards with no modification required.