Bryant Furnace 312AAV042090AAJA Parts

Shop replacement repair parts for Bryant Furnace model 312AAV042090AAJA

icons/furnace
Brand:Bryant
Model:312AAV042090AAJA
Product:Furnace
96 results
Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a bestsellerProduct is a manufacturer part
LH680534 Flame Sensor
$51.99

Furnace flame sensor. The flame sensor monitors the burner to detect whether or not a flame is present. If the flame sensor is defective, the furnace may not heat.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a bestsellerProduct is a manufacturer part
349336-763 Draft Inducer Motor
$287.75

Furnace draft inducer motor kit. The draft inducer motor draws air into the burner and exhausts it out the flue. If the draft inducer motor is defective, the furnace may not heat.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
KA56GR560 Grommet
$15.82

Furnace draft inducer mounting grommet. This grommet helps isolate the blower assembly from the furnace to reduce noise.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
LA660003 Fan Blade
$14.19

Furnace draft inducer motor cooling fan blade and clip. You may have to cut the old clip off to remove the fan blade.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
349336-762 Draft Inducer Motor Assembly
$335.91

Furnace draft inducer motor kit. The draft inducer motor draws air into the burner and exhausts it out the flue. If the draft inducer motor is defective, the furnace may not heat.

Go

Bryant 312AAV042090AAJA Problems & Repair Solutions

There are only a handful of issues that crop up with most appliances and equipment. Since 1912, we've learned to recognize the most common Bryant 312AAV042090AAJA problems ― and their solutions. Do any of these look familiar?
Furnace not heating
32 possible causes and potential solutions
Furnace not heating
Furnace is noisy or loud
16 possible causes and potential solutions
Furnace is noisy or loud
Furnace starts then stops
22 possible causes and potential solutions
Furnace starts then stops

Frequently Purchased Together For This Model

Flame Sensor
Flame Rollout Limit Switch
Limit Switch
Draft Inducer Motor

Keep your 312AAV042090AAJA furnace running efficiently with genuine OEM replacement parts from Repair Clinic. The 312AAV042090AAJA is a 90000 BTU input, 80% AFUE gas furnace from Bryant. The furnace uses standard metal B-vent, produces no condensate, and has a straightforward non-condensing service profile. Bryant and Carrier are sister brands under the same parent company. Service components for the 312AAV042090AAJA and its Carrier equivalent at the same configuration are fully interchangeable. The igniter, flame sensor, standard metal B-vent, and control board account for the majority of service calls. Repair Clinic stocks genuine Bryant OEM parts for the 312AAV042090AAJA including the Bryant igniter parts, Bryant flame sensor parts, Bryant draft inducer motor parts, and Bryant control board parts. Browse the Bryant furnace parts catalog filtered by 312AAV042090AAJA for the complete parts inventory.

312AAV042090AAJA: 90000 BTU, 80% AFUE Gas Furnace Service

Reading the control board LED blink code before ordering any component is the required first diagnostic step on the 312AAV042090AAJA. The blink code identifies the specific component fault. Annual flame sensor cleaning with fine steel wool prevents most nuisance lockouts. The Bryant furnace troubleshooting guide covers fault code blink patterns for this platform.

Most Replaced Parts on the 312AAV042090AAJA

Hot Surface Igniter for the 312AAV042090AAJA

Testing resistance at room temperature with power off confirms failure in under two minutes. An infinite ohm reading means the element is open-circuit and must be replaced before any heating cycle can complete.

312AAV042090AAJA Flame Sensor

Annual cleaning with fine steel wool extends sensor service life and prevents most early-season nuisance lockouts.

Draft Inducer Motor for the 312AAV042090AAJA

{‘Bearing failure presents as grinding during the pre-purge phase at startup and should be replaced before complete seizure.’ if not condensing else ‘The condensing-rated inducer must tolerate moisture from condensate-laden flue gases and must not be substituted with a standard 80% AFUE inducer. Bearing failure presents as grinding during the pre-purge phase.’}

312AAV042090AAJA Control Board

Read and document the two-digit LED blink code before ordering any replacement. The blink code directs the diagnosis to the specific failed component.

Why Choose Repair Clinic for 312AAV042090AAJA Parts

  • Genuine Bryant OEM Components: Igniters, flame sensors, and inducers confirmed for the 312AAV042090AAJA 90000 BTU platform Bryant furnace parts.
  • Fault Code Diagnostic Resources: The Bryant furnace troubleshooting LED blink code chart is available alongside every part listing.
  • Non-Condensing B-Vent Context: The furnace uses standard metal B-vent, produces no condensate, and has a straightforward non-condensing service profile.
  • 365-Day Returns: Return any uninstalled part within a full year of purchase with no restocking fees.

312AAV042090AAJA Furnace Parts FAQ

What is the BTU output and efficiency of the 312AAV042090AAJA?

The 312AAV042090AAJA is a 90000 BTU input, 80% AFUE gas furnace from Bryant. The furnace uses standard metal B-vent, produces no condensate, and has a straightforward non-condensing service profile.

What type of venting does the 312AAV042090AAJA require?

Standard metal B-vent. It produces no condensate and does not use PVC plastic venting.

My 312AAV042090AAJA ignites and shuts off within seconds. What is wrong?

This is the flame sensor symptom. The sensor rod has oxidized and cannot pass adequate micro-amp current to confirm sustained combustion. Annual cleaning with fine steel wool prevents most occurrences.

How is the Bryant 312AAV042090AAJA related to a Carrier equivalent furnace?

Bryant and Carrier are sister brands under the same parent company. The Bryant 312AAV042090AAJA and its Carrier equivalent at the same configuration share the same platform engineering and all service components are fully interchangeable between both brand designations.