Bryant Central Air Conditioner 561CJX024000ACAA Parts

Shop replacement repair parts for Bryant Central Air Conditioner model 561CJX024000ACAA

icons/central air condenser
Brand:Bryant
Model:561CJX024000ACAA
Product:Central Air Conditioner
57 results
Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
HN51KC024 Contactor
$71.91

You need Contactor HN51KC024 if you're having trouble with the compressor or fan motor on your air conditioner, furnace, heat pump, or air handler. This genuine OEM single-pole, 24-volt coil contactor has a full load amps (FLA) rating of 30 amps and a locked rotor amps (LRA) rating of 150 amps.

Product is a manufacturer part
Triple-D-AER Cleaner
$26.10

Triple-D Coil Cleaner is a 19oz Aerosol spray can, that is safe for homeowner use. One can will clean an entire outdoor condenser coil and/or indoor evaporator coil, to remove energy-stealing dirt, debris and soot.

Skill Level (3)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
HC33GE208 Condenser Fan Motor
$342.52

Condenser Fan Motor - 1/6 HP 208-230Volts 60Hertz 0.9Amps 1500RPMSpeed Closed Enclosure 48Y Frame Single Phase CW Rotation 1.75" Shaft

Skill Level (1)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
21986 Pump
$102.51

Condensate Pump.
Features:
* 16 foot lift
* Whisper quiet
* ½ Gallon Reservoir
* Rubber isolation feet
* 3/8" Check Valve

Go

Bryant 561CJX024000ACAA Problems & Repair Solutions

There are only a handful of issues that crop up with most appliances and equipment. Since 1912, we've learned to recognize the most common Bryant 561CJX024000ACAA problems ― and their solutions. Do any of these look familiar?

Frequently Purchased Together For This Model

Contactor
Screw
Nut
Grommet

Ensure your 561CJX024000ACAA central air conditioner running efficiently with genuine OEM replacement parts from Repair Clinic. The 561CJX024000ACAA is a two-ton residential outdoor condensing unit using R-410A Puron refrigerant. The 561CJX designation identifies a Bryant residential outdoor condensing unit series. Bryant and Carrier are sister brands under the same parent company with interchangeable service components at equivalent configurations. The dual run capacitor, contactor, and outdoor fan motor account for the vast majority of service calls. Repair Clinic stocks genuine Bryant OEM parts for the 561CJX024000ACAA including the Bryant capacitor parts, Bryant contactor parts, Bryant fan motor parts, and Bryant high-pressure switch parts. Browse the Bryant central air conditioner parts catalog filtered by 561CJX024000ACAA for the complete parts inventory.

561CJX024000ACAA: Two-Ton Outdoor Condensing Unit Service

Annual capacitance testing of the dual run capacitor before the cooling season is the most cost-effective preventive maintenance step for the 561CJX024000ACAA. Match all microfarad values from the installed capacitor label before ordering a replacement. The central air conditioner repair help section covers capacitor testing and contactor diagnosis for this platform.

Most Replaced Parts on the 561CJX024000ACAA

Dual Run Capacitor for the 561CJX024000ACAA

The dual run capacitor provides starting and running torque for both the compressor and outdoor fan motor. A reading more than 10% below the rated value causes the compressor to hard-start. Match all three microfarad values from the installed capacitor label before ordering.

561CJX024000ACAA Contactor

The contactor closes the 240-volt compressor circuit at every cooling cycle start. Pitted or burned contacts generate heat that transfers to the compressor motor terminals. Replace a contactor with visibly eroded contacts before compressor winding damage occurs.

Outdoor Fan Motor for the 561CJX024000ACAA

The outdoor fan motor pulls air through the condenser coil. Test the run capacitor before ordering a replacement motor, as a failed capacitor produces identical slow-start symptoms at a fraction of the motor replacement cost.

High-Pressure Switch for the 561CJX024000ACAA

A high-pressure switch that trips repeatedly under normal ambient conditions points to a blocked condenser coil, failed fan motor, or refrigerant overcharge rather than a failed switch diaphragm.

Why Choose Repair Clinic for 561CJX024000ACAA Parts

  • Genuine Bryant 561CJX OEM Components: Two-ton dual run capacitors, contactors, and fan motors confirmed for the 561CJX024000ACAA with Carrier cross-reference Bryant central air conditioner parts.
  • R-410A Puron Platform: The 561CJX024000ACAA uses R-410A refrigerant. Refrigerant circuit service requires EPA 608 certified technicians.
  • Annual Capacitor Testing Priority: Pre-season capacitance testing is the most cost-effective preventive maintenance step for the 561CJX024000ACAA.
  • 365-Day Returns: Return any uninstalled part within a full year of purchase with no restocking fees.

561CJX024000ACAA Parts FAQ

What is the 561CJX024000ACAA and what ton size is it?

The 561CJX024000ACAA is a two-ton residential outdoor condensing unit using R-410A Puron refrigerant. The 561CJX designation identifies a Bryant residential outdoor condensing unit series. Bryant and Carrier are sister brands under the same parent company with interchangeable service components at equivalent configurations.

Why does my 561CJX024000ACAA hum but not start?

A unit that hums but does not start has most commonly failed at the dual run capacitor. Test the capacitor with a digital capacitance meter before testing any other component.

What refrigerant does the Bryant 561CJX024000ACAA use?

Confirm the refrigerant type from the unit data plate, as older Bryant 561CJX series units may use R-22 depending on the specific production year. Always verify before ordering refrigerant circuit components, since R-22 service requires EPA 608 certified technicians.

How often should I test the capacitor on the 561CJX024000ACAA?

Test the capacitor annually before the cooling season. A reading more than 10% below the rated microfarad value indicates a weakening capacitor that should be replaced before it fails under peak summer load.