Maintain your 10ACC-060-230-2 central air conditioner running efficiently with genuine OEM replacement parts from Repair Clinic. The 10ACC-060-230-2 is a five-ton R-22 residential outdoor condensing unit using R-22 refrigerant. The 10ACC-060 is the highest-tonnage configuration in Lennox’s 10ACC series, above the four-ton 10ACC-048 and two-ton 10ACC-024. The dual run capacitor, contactor, and outdoor fan motor account for the vast majority of service calls. Repair Clinic stocks genuine Lennox OEM parts for the 10ACC-060-230-2 including the Lennox capacitor parts, Lennox contactor parts, Lennox fan motor parts, and Lennox high-pressure switch parts. Browse the Lennox central air conditioner parts catalog filtered by 10ACC-060-230-2 for the complete parts inventory.
10ACC-060-230-2: Five-Ton R-22 Outdoor Condensing Unit Service
Annual capacitance testing of the dual run capacitor before the cooling season is the most cost-effective preventive maintenance step for the 10ACC-060-230-2. Match all microfarad values from the installed capacitor label before ordering a replacement. The central air conditioner repair help section covers capacitor testing and contactor diagnosis for this platform.
Most Replaced Parts on the 10ACC-060-230-2
Dual Run Capacitor for the 10ACC-060-230-2
The dual run capacitor provides starting and running torque for both the compressor and outdoor fan motor. A reading more than 10% below the rated value causes the compressor to hard-start. Match all three microfarad values from the installed capacitor label before ordering.
10ACC-060-230-2 Contactor
The contactor closes the 240-volt compressor circuit at every cooling cycle start. Pitted or burned contacts generate heat that transfers to the compressor motor terminals. Replace a contactor with visibly eroded contacts before compressor winding damage occurs.
Outdoor Fan Motor for the 10ACC-060-230-2
The outdoor fan motor pulls air through the condenser coil. Test the run capacitor before ordering a replacement motor, as a failed capacitor produces identical slow-start symptoms at a fraction of the motor replacement cost.
High-Pressure Switch for the 10ACC-060-230-2
A high-pressure switch that trips repeatedly under normal ambient conditions points to a blocked condenser coil, failed fan motor, or refrigerant overcharge rather than a failed switch diaphragm.
Why Choose Repair Clinic for 10ACC-060-230-2 Parts
- Genuine Lennox 10ACC OEM Components: Five-ton run capacitors, contactors, and fan motors confirmed for the 10ACC-060-230-2 R-22 platform Lennox central air conditioner parts.
- R-22 Refrigerant Circuit Context: The 10ACC-060-230-2 uses R-22 refrigerant. Refrigerant circuit service requires EPA 608 certified technicians with access to reclaimed R-22.
- Annual Capacitor Testing Priority: Pre-season capacitance testing is the most cost-effective preventive maintenance step for the 10ACC-060-230-2.
- 365-Day Returns: Return any uninstalled part within a full year of purchase with no restocking fees.
10ACC-060-230-2 Parts FAQ
What is the 10ACC-060-230-2 and what ton size is it?
The 10ACC-060-230-2 is a five-ton R-22 residential outdoor condensing unit using R-22 refrigerant. The 10ACC-060 is the highest-tonnage configuration in Lennox’s 10ACC series, above the four-ton 10ACC-048 and two-ton 10ACC-024.
Why does my 10ACC-060-230-2 hum but not start?
A unit that hums but does not start has most commonly failed at the dual run capacitor. Test the capacitor with a digital capacitance meter before testing any other component.
How does the Lennox 10ACC-060-230-2 differ from the 10ACC-024-230-2?
The 10ACC-060-230-2 is a five-ton unit while the 10ACC-024-230-2 is a two-ton unit in the same Lennox 10ACC R-22 product line. The run capacitor carries different compressor-section microfarad ratings between the two tonnages.
How often should I test the capacitor on the 10ACC-060-230-2?
Test the capacitor annually before the cooling season. A reading more than 10% below the rated microfarad value indicates a weakening capacitor that should be replaced before it fails under peak summer load.