Lennox Central Air Conditioner 13ACD-024-230-2 Parts

Shop replacement repair parts for Lennox Central Air Conditioner model 13ACD-024-230-2

Lennox Central Air Conditioner 13ACD-024-230-2 Parts
Brand:Lennox
Model:13ACD-024-230-2
Product:Central Air Conditioner
34 results
Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
10F73 Contactor
$34.77

Contactor, 25 amp, 1-pole, 24 vac 60/50 hz coil

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
12Y75 Fan Motor
$110.53

Fan motor. 1/5 HP, 208/230 volts, 60/50 hertz.

Product is a manufacturer part
Triple-D-AER Cleaner
$26.10

Triple-D Coil Cleaner is a 19oz Aerosol spray can, that is safe for homeowner use. One can will clean an entire outdoor condenser coil and/or indoor evaporator coil, to remove energy-stealing dirt, debris and soot.

Skill Level (1)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
21986 Pump
$102.51

Condensate Pump.
Features:
* 16 foot lift
* Whisper quiet
* ½ Gallon Reservoir
* Rubber isolation feet
* 3/8" Check Valve

Skill Level (4)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
86H31 Pressure Switch
$75.31

Hi limit resetable pressure switch. Actuates at 410 PSI

Go

Lennox 13ACD-024-230-2 Problems & Repair Solutions

There are only a handful of issues that crop up with most appliances and equipment. Since 1912, we've learned to recognize the most common Lennox 13ACD-024-230-2 problems ― and their solutions. Do any of these look familiar?

Frequently Purchased Together For This Model

Contactor
Fan Motor
Dual Run Capacitor
Cleaner

Maintain your 13ACD-024-230-2 central air conditioner running efficiently with genuine OEM replacement parts from Repair Clinic. The 13ACD-024-230-2 is a two-ton R-22 residential outdoor condensing unit using R-22 refrigerant. The 13ACD-024 is the two-ton configuration in Lennox’s 13ACD series, the smallest standard tonnage below the two-and-a-half-ton 13ACD-030 and four-ton 13ACD-048. The dual run capacitor, contactor, and outdoor fan motor account for the vast majority of service calls. Repair Clinic stocks genuine Lennox OEM parts for the 13ACD-024-230-2 including the Lennox capacitor parts, Lennox contactor parts, Lennox fan motor parts, and Lennox high-pressure switch parts. Browse the Lennox central air conditioner parts catalog filtered by 13ACD-024-230-2 for the complete parts inventory.

13ACD-024-230-2: Two-Ton R-22 Outdoor Condensing Unit Service

Annual capacitance testing of the dual run capacitor before the cooling season is the most cost-effective preventive maintenance step for the 13ACD-024-230-2. Match all microfarad values from the installed capacitor label before ordering a replacement. The central air conditioner repair help section covers capacitor testing and contactor diagnosis for this platform.

Most Replaced Parts on the 13ACD-024-230-2

Dual Run Capacitor for the 13ACD-024-230-2

The dual run capacitor provides starting and running torque for both the compressor and outdoor fan motor. A reading more than 10% below the rated value causes the compressor to hard-start. Match all three microfarad values from the installed capacitor label before ordering.

13ACD-024-230-2 Contactor

The contactor closes the 240-volt compressor circuit at every cooling cycle start. Pitted or burned contacts generate heat that transfers to the compressor motor terminals. Replace a contactor with visibly eroded contacts before compressor winding damage occurs.

Outdoor Fan Motor for the 13ACD-024-230-2

The outdoor fan motor pulls air through the condenser coil. Test the run capacitor before ordering a replacement motor, as a failed capacitor produces identical slow-start symptoms at a fraction of the motor replacement cost.

High-Pressure Switch for the 13ACD-024-230-2

A high-pressure switch that trips repeatedly under normal ambient conditions points to a blocked condenser coil, failed fan motor, or refrigerant overcharge rather than a failed switch diaphragm.

Why Choose Repair Clinic for 13ACD-024-230-2 Parts

  • Genuine Lennox 13ACD OEM Components: Two-ton run capacitors, contactors, and fan motors confirmed for the 13ACD-024-230-2 R-22 platform Lennox central air conditioner parts.
  • R-22 Refrigerant Circuit Context: The 13ACD-024-230-2 uses R-22 refrigerant. Refrigerant circuit service requires EPA 608 certified technicians with access to reclaimed R-22.
  • Annual Capacitor Testing Priority: Pre-season capacitance testing is the most cost-effective preventive maintenance step for the 13ACD-024-230-2.
  • 365-Day Returns: Return any uninstalled part within a full year of purchase with no restocking fees.

13ACD-024-230-2 Parts FAQ

What is the 13ACD-024-230-2 and what ton size is it?

The 13ACD-024-230-2 is a two-ton R-22 residential outdoor condensing unit using R-22 refrigerant. The 13ACD-024 is the two-ton configuration in Lennox’s 13ACD series, the smallest standard tonnage below the two-and-a-half-ton 13ACD-030 and four-ton 13ACD-048.

Why does my 13ACD-024-230-2 hum but not start?

A unit that hums but does not start has most commonly failed at the dual run capacitor. Test the capacitor with a digital capacitance meter before testing any other component.

How does the Lennox 13ACD-024-230-2 differ from the 13ACD-030-230-1?

The 13ACD-024-230-2 is a two-ton unit while the 13ACD-030-230-1 is a two-and-a-half-ton unit in the same Lennox 13ACD R-22 product line. The run capacitor carries different compressor-section microfarad ratings between the two tonnages.

How often should I test the capacitor on the 13ACD-024-230-2?

Test the capacitor annually before the cooling season. A reading more than 10% below the rated microfarad value indicates a weakening capacitor that should be replaced before it fails under peak summer load.