ICP NAC030AKC3 Central Air Conditioner Parts

Shop replacement repair parts for ICP Central Air Conditioner model NAC030AKC3

icons/central air condenser
Brand:ICP
Model:NAC030AKC3
Product:Central Air Conditioner
24 results
Product is a manufacturer part
Triple-D-AER Cleaner
$26.10

Triple-D Coil Cleaner is a 19oz Aerosol spray can, that is safe for homeowner use. One can will clean an entire outdoor condenser coil and/or indoor evaporator coil, to remove energy-stealing dirt, debris and soot.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
1085958 Fan Blade
$211.72

3 Blade fan, 18" diameter 28 degree 1/2" CW

Skill Level (1)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
21986 Pump
$102.51

Condensate Pump.
Features:
* 16 foot lift
* Whisper quiet
* ½ Gallon Reservoir
* Rubber isolation feet
* 3/8" Check Valve

Skill Level (3)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
1088235 Condenser Fan Motor
$377.02

1/5 HP 208-230Volts 60Hertz 1.08Amps 1075RPM Single Speed Closed Enclosure 42Y Frame Single Phase CCW Rotation 2" Shaft

Skill Level (4)
skill level dotskill level dotskill level dotskill level dot
Product is a bestsellerProduct is a manufacturer part
CR28K6PFV775 Compressor
N/A

Comp cr28k6-pfv-775

No Longer Available
Go

ICP NAC030AKC3 Problems & Repair Solutions

There are only a handful of issues that crop up with most appliances and equipment. Since 1912, we've learned to recognize the most common ICP NAC030AKC3 problems ― and their solutions. Do any of these look familiar?

Frequently Purchased Together For This Model

Contactor
Cleaner
Fan Blade
Run Capacitor

Maintain your ICP NAC030AKC3 central air conditioner with genuine OEM replacement parts from Repair Clinic. The NAC030AKC3 is a 2.5-ton single-stage cooling-only condensing unit in ICP’s NAC series. ICP (International Comfort Products) also sells this platform under the Heil, Tempstar, WeatherKing, and Arcoaire brand designations; parts ordered under any of these ICP brand channels at the same 2.5-ton NAC configuration are interchangeable. The nac036akc3 and nac024akc3 are 3-ton and 2-ton configurations in the same NAC platform; their fan motors and blades are sized for their respective output classes and are not interchangeable with the NAC030AKC3 components. Parts most frequently replaced include the run capacitor, contactor, condenser fan motor, and fan blade. Use the NAC030AKC3 parts list and browse the full ICP central air conditioner parts catalog.

NAC030AKC3 on the ICP Platform: 2.5-Ton Output Class and Multi-Brand Interchangeability

The ICP NAC030AKC3 is a 2.5-ton (30,000 BTU) condensing unit manufactured by International Comfort Products on the same platform shared by Heil, Tempstar, WeatherKing, and Arcoaire. The nac024akc3 air conditioner model is the 2-ton variant in the same NAC series, and the nac036akc3 is the 3-ton variant; confirming the 030 output class designation is essential when ordering fan motors and blades because these components are sized for their respective condenser coil outputs and are not interchangeable across the 024, 030, and 036 output classes within the same NAC platform generation. The NAC030AKC3 manual documents refrigerant charge specification and component locations for the 2.5-ton configuration. For diagnostic guidance, visit the ICP air conditioner troubleshooting section.

NAC030AKC3 Service Items and Wear Patterns at the 2.5-Ton Class

NAC030AKC3 Capacitor Dual-Section Testing and Symptom Pattern Identification

The NAC030AKC3 capacitor is a dual-run unit serving the 2.5-ton compressor and condenser fan motor independently from a single housing. The compressor section and fan motor section degrade independently, producing distinct symptom patterns before testing. A compressor that hums and trips thermal protection while the fan runs normally has a failed compressor section; a fan that does not start while the compressor runs has a failed fan motor section. Annual microfarad testing at cooling season start is the highest-impact preventive maintenance step on this unit. Browse ICP central air conditioner capacitor parts.

ICP NAC030AKC3 Contactor Contact Face Inspection

The contactor on the ICP NAC030AKC3 switches line voltage to the compressor and fan motor at every thermostat cooling cycle. Arc erosion accumulates through thousands of switching cycles, raising contact resistance and reducing voltage delivered to the compressor. Inspect the contact faces at each annual service; replace the NAC030AKC3 contactor when any pitting or erosion is visible. Find compatible options at the ICP air conditioner contactor page.

NAC030AKC3 Fan Motor Bearing Condition and 030-Class Airflow Requirement

The NAC030AKC3 fan motor is sized for the 2.5-ton condenser coil’s airflow requirement. Bearing wear reduces operating RPM below the rated design point, cutting coil airflow and raising condensing pressure. Replace the motor at the first sign of bearing noise. When ordering, confirm the 030 output class from the full model number; the nac024akc3 motor and nac036akc3 motor are not interchangeable with the NAC030AKC3 motor. Browse ICP central air conditioner fan motor parts.

NAC030AKC3 Fan Blade Physical Inspection and 2.5-Ton Specification Matching

The NAC030AKC3 fan blade is pitched for the 2.5-ton coil airflow requirement. Inspect the blade annually for tip damage, surface corrosion, and hub cracking that create imbalance and accelerate motor bearing wear. Confirm the blade diameter, pitch angle, and hub bore from the NAC030AKC3 parts list before ordering. Browse ICP central air conditioner fan blade parts.

ICP NAC030AKC3 Parts at Repair Clinic

  • ICP Platform OEM Parts for Heil, Tempstar, WeatherKing, and Arcoaire: Every NAC030AKC3 part is interchangeable across all ICP brand designations at the same 2.5-ton NAC configuration. Browse the full ICP central air conditioner parts catalog.
  • 030, 024, and 036 Output Class Separation: Our listings distinguish the 2.5-ton NAC030AKC3 fan motor and blade from the nac024akc3 (2-ton) and nac036akc3 (3-ton) configurations, preventing the airflow mismatch errors caused by ordering across output classes.
  • NAC030AKC3 Parts List and Diagram Access: The interactive diagram identifies components by position in the cabinet for accurate identification before ordering.
  • Fast Shipping During Cooling Season: In-stock NAC030AKC3 parts ship promptly, supported by the ICP air conditioner troubleshooting section.

ICP NAC030AKC3 Central Air Conditioner Parts FAQ

What is the tonnage of the ICP NAC030AKC3?

The ICP NAC030AKC3 is a 2.5-ton (30,000 BTU) condensing unit. The 030 in the model number identifies the 30,000 BTU output class. The nac024akc3 air conditioner model is a 2-ton variant and the nac036akc3 is a 3-ton variant; fan motors and blades from these output classes are not interchangeable with the NAC030AKC3 components.

What ICP brand channel parts are interchangeable with the NAC030AKC3?

Heil, Tempstar, WeatherKing, and Arcoaire are all ICP brand channels sharing the same manufacturing platform as the ICP NAC030AKC3. Parts ordered under any of these designations at the same 2.5-ton NAC030 configuration are identical and interchangeable with no modification required.

Where can I find the NAC030AKC3 manual?

The NAC030AKC3 manual is available through ICP’s technical documentation portal and is referenced on the Repair Clinic listing page for this model. The nac036akc3 manual covers the 3-ton configuration of the same platform and may also provide useful reference for shared system features. The manual documents the refrigerant charge specification, electrical data, and component locations for the 2.5-ton NAC030AKC3.

How do I confirm the correct fan blade for the NAC030AKC3?

Confirm the blade diameter, pitch angle, and hub bore from the NAC030AKC3 parts list on the Repair Clinic listing page before ordering. A blade matched by diameter alone but with incorrect pitch produces inadequate airflow for the 2.5-ton coil even when physically installed; all three specifications must match the NAC030AKC3 030-class design requirement.