ICP Central Air Conditioner NAC036AKA1 Parts

Shop replacement repair parts for ICP Central Air Conditioner model NAC036AKA1

icons/central air condenser
Brand:ICP
Model:NAC036AKA1
Product:Central Air Conditioner
21 results
Product is a manufacturer part
Triple-D-AER Cleaner
$26.10

Triple-D Coil Cleaner is a 19oz Aerosol spray can, that is safe for homeowner use. One can will clean an entire outdoor condenser coil and/or indoor evaporator coil, to remove energy-stealing dirt, debris and soot.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
1085958 Fan Blade
$211.72

3 Blade fan, 18" diameter 28 degree 1/2" CW

Skill Level (1)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
21986 Pump
$102.51

Condensate Pump.
Features:
* 16 foot lift
* Whisper quiet
* ½ Gallon Reservoir
* Rubber isolation feet
* 3/8" Check Valve

Skill Level (3)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
1086486 Condenser Fan Motor
$393.00

1/5 HP 208-230Volts 60Hertz 1.08Amps 1075RPM Single Speed Closed Enclosure 42Y Frame Single Phase CW Rotation 1.75" Shaft

Skill Level (4)
skill level dotskill level dotskill level dotskill level dot
Product is a bestsellerProduct is a manufacturer part
CR32K6PFV775 Compressor
N/A

Comp cr32k6-pfv-775

No Longer Available
Go

ICP NAC036AKA1 Problems & Repair Solutions

There are only a handful of issues that crop up with most appliances and equipment. Since 1912, we've learned to recognize the most common ICP NAC036AKA1 problems ― and their solutions. Do any of these look familiar?

Frequently Purchased Together For This Model

Contactor
Cleaner
Fan Blade
Dual Run Capacitor

Keep your NAC036AKA1 central air conditioner running efficiently with genuine OEM replacement parts from Repair Clinic. The NAC036AKA1 is a three-ton residential outdoor condensing unit using R-410A Puron refrigerant. ICP, Heil, Tempstar, Arcoaire, and WeatherKing are all International Comfort Products brand designations sharing the same platform engineering and fully interchangeable service components at the same model configuration. The dual run capacitor, contactor, and outdoor fan motor account for the vast majority of service calls. Repair Clinic stocks genuine ICP OEM parts for the NAC036AKA1 including the ICP capacitor parts, ICP contactor parts, ICP fan motor parts, and ICP high-pressure switch parts. Browse the ICP central air conditioner parts catalog filtered by NAC036AKA1 for the complete parts inventory.

NAC036AKA1: Three-Ton Outdoor Condensing Unit Service

Annual capacitance testing of the dual run capacitor before the cooling season is the most cost-effective preventive maintenance step for the NAC036AKA1. Match all microfarad values from the installed capacitor label before ordering a replacement. The central air conditioner repair help section covers capacitor testing and contactor diagnosis for this platform.

Most Replaced Parts on the NAC036AKA1

Dual Run Capacitor for the NAC036AKA1

The dual run capacitor provides starting and running torque for both the compressor and outdoor fan motor. A reading more than 10% below the rated value causes the compressor to hard-start. Match all three microfarad values from the installed capacitor label before ordering.

NAC036AKA1 Contactor

The contactor closes the 240-volt compressor circuit at every cooling cycle start. Pitted or burned contacts generate heat that transfers to the compressor motor terminals. Replace a contactor with visibly eroded contacts before compressor winding damage occurs.

Outdoor Fan Motor for the NAC036AKA1

The outdoor fan motor pulls air through the condenser coil. Test the run capacitor before ordering a replacement motor, as a failed capacitor produces identical slow-start symptoms at a fraction of the motor replacement cost.

High-Pressure Switch for the NAC036AKA1

A high-pressure switch that trips repeatedly under normal ambient conditions points to a blocked condenser coil, failed fan motor, or refrigerant overcharge rather than a failed switch diaphragm.

Why Choose Repair Clinic for NAC036AKA1 Parts

  • Genuine ICP OEM Components: Three-ton dual run capacitors, contactors, and fan motors confirmed for the NAC036AKA1 with Heil, Tempstar, Arcoaire, and WeatherKing cross-reference ICP central air conditioner parts.
  • R-410A Puron Platform: The NAC036AKA1 uses R-410A refrigerant. Refrigerant circuit service requires EPA 608 certified technicians.
  • Annual Capacitor Testing Priority: Pre-season capacitance testing is the most cost-effective preventive maintenance step for the NAC036AKA1.
  • 365-Day Returns: Return any uninstalled part within a full year of purchase with no restocking fees.

NAC036AKA1 Parts FAQ

What is the NAC036AKA1 and what ton size is it?

The NAC036AKA1 is a three-ton residential outdoor condensing unit using R-410A Puron refrigerant. ICP, Heil, Tempstar, Arcoaire, and WeatherKing are all International Comfort Products brand designations sharing the same platform engineering and fully interchangeable service components at the same model configuration.

Why does my NAC036AKA1 hum but not start?

A unit that hums but does not start has most commonly failed at the dual run capacitor. Test the capacitor with a digital capacitance meter before testing any other component.

How does the ICP NAC036AKA1 differ from the NAC030AKA1?

The NAC036AKA1 is a three-ton unit while the NAC030AKA1 is a two-and-a-half-ton unit in the same ICP NAC residential outdoor condensing unit series. The dual run capacitor carries different compressor-section microfarad ratings between the two tonnages. Never substitute capacitor specifications between the 036 and 030 configurations.

How often should I test the capacitor on the NAC036AKA1?

Test the capacitor annually before the cooling season. A reading more than 10% below the rated microfarad value indicates a weakening capacitor that should be replaced before it fails under peak summer load.