Shop replacement repair parts for York Air Handler model N1AHB1206A

Run capacitor, single,10mfd,370 volts, oval

Furnace fan/electric heat control board.

Blower Motor 1/2hp 1075rpm/3sp ccw 208/230 1ph
Keep your York N1AHB1206A air handler running reliably with genuine OEM replacement parts from Repair Clinic. The N1AHB1206A is a five-ton residential air handler from York’s N1AHB series. York, Coleman HVAC, and Luxaire are all Johnson Controls brand designations sharing the same platform engineering and interchangeable service components. The blower motor, run capacitor, and control board account for the majority of N1AHB1206A service calls. Repair Clinic stocks genuine York OEM parts for the N1AHB1206A including the York air handler blower motor parts, York air handler capacitor parts, York air handler control board parts, and York air handler drain pan parts. Browse the York air handler parts catalog filtered by N1AHB1206A for the complete parts inventory.
The York N1AHB1206A is a five-ton residential air handler that shares its platform with Coleman HVAC and Luxaire models at the same configuration under the Johnson Controls parent company. All service components are interchangeable across all Johnson Controls brand designations. Annual run capacitor testing before the cooling season is especially important in heat pump applications where the blower motor runs year-round.
A five-ton blower motor moves a substantial air volume. In heat pump applications this motor runs year-round, accumulating more annual hours than in cooling-only installations. Test the run capacitor before ordering a replacement motor.
A capacitor reading more than 10% below its rated microfarad value causes the blower motor to run hot at reduced airflow. Annual testing catches a weakening capacitor before it fails.
A board fault typically presents as the unit not responding to thermostat signals or running continuously. Read the board LED blink code before ordering a replacement.
A drain pan that overflows continuously has a clogged condensate drain outlet. Clear the drain line completely before replacing the pan to confirm whether the pan itself is cracked.
The York N1AHB1206A is a five-ton residential air handler from York’s N1AHB series. York, Coleman HVAC, and Luxaire are all Johnson Controls brand designations sharing the same platform engineering and interchangeable service components at the same configuration.
No airflow from the N1AHB1206A is most commonly caused by a failed run capacitor preventing the blower motor from starting, a tripped circuit breaker, or a clogged air filter restricting airflow. Check the filter and breaker before testing the capacitor and blower motor.
Yes. The N1AHB1206A is compatible with York and Johnson Controls heat pump and air conditioner outdoor units in the five-ton R-410A category. In heat pump applications the blower motor runs year-round, making the run capacitor a higher-wear item than in cooling-only installations.
A control board fault typically presents as the air handler not responding to thermostat calls, running continuously without responding to the off signal, or displaying fault indicators. Read the board LED blink code before ordering a replacement.

Family-owned and operated since 1912, Burke America Parts Group is the longest-running genuine appliance, HVAC, and outdoor power equipment parts solution in North America. At Repair Clinic, we're proud to be an international brand trusted by the pros as well as the DIY community.
About Repair Clinic