HomePartsYork Parts

York Parts

Browse genuine OEM York Parts for furnaces, air conditioners, and heat pumps, including control boards, igniters, motors, and more. Find the right part for your model, then order with a price match guarantee, same-day shipping on in-stock parts, and 365-day returns to restore heating and cooling.

Find the right part faster

Multiple models matched. Select your model to confirm fit.

7,553 results for 
York
Sort:
Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a bestsellerProduct is a manufacturer part
S1-03103010000 Control Board
$172.89

Furnace control board. The control board regulates the supply of power to the furnace components.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-02532625000 Igniter
$84.39

Furnace hot surface igniter kit. The igniter gets very hot and glows bright orange to light the gas burner. If the igniter is cracked or defective, the furnace won’t heat.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-02527773700 Flame Sensor
$39.60

Furnace flame sensor. The flame sensor monitors the burner to detect whether or not a flame is present. If the flame sensor is defective, the furnace may not heat.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-02420046700 Run Capacitor
$14.23

Run capacitor, single,10mfd,370 volts, oval

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-02537499000 Flame Sensor
$71.91

Furnace flame sensor. The flame sensor monitors the burner to detect whether or not a flame is present. If the flame sensor is defective, the furnace may not heat.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-02420045700 Run Capacitor
$13.07

Genteq Run Capacitor 370 Volt Oval Single 7.5 MFD

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-02442415000 Contactor
$48.50

Contactor with shunt, 1 pole, 30 amps, 24 volts

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-02541318000 Flame Rollout Limit Switch
$15.87

Flame rollout limit switch, push button to re-set

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a bestsellerProduct is a manufacturer part
S1-02440901000 Blower Motor
$361.36

Furnace blower motor. This single-phase motor has the following specifications:

Horsepower: 1/2
Voltage: 115
Full-Load Amperage: 7.7
Hertz: 60
RPM: 1175
Speeds: 4
Rotation: Counterclockwise
Frame: 48
Enclosure: Open

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-S90-380 Relay
$31.17

Fan relay, 24v coil, 50-60hz, spst-no/nc

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-02649692000 Draft Inducer Motor
$273.58

Furnace draft inducer motor. The draft inducer motor draws air into the burner and exhausts it out the flue. If the draft inducer motor is defective, the furnace may not heat.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-7624A3591 Limit Switch
$27.69

Upper limit switch 180° manual reset
manufacture approved alternate for
this limit switch part# S1-7990-3591

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-02435329000 Draft Inducer Motor
$363.21

Draft inducer blower assembly. 60 Hz 1.75 Amps, 3000 RPM.The draft inducer blower draws air into the burner and exhausts it out the flue. If the draft inducer motor is defective, the furnace may not heat.

Go
Find. Fix. Finish.
Whether you're a pro or a novice, we've got you covered with the repair know-how and replacement York parts you need.
Genuine OEM Parts Supplier
Genuine OEM York Replacement Parts
Get peace of mind with the real thing—genuine OEM York parts.
365-Day Appliance Parts Return Policy
No-Hassle 365-Day Returns
Return uninstalled York parts and products for any reason within 365 days of purchase.
Same day shipping
Same-Day Shipping
Get the job finished. Order replacement York parts by 9:00 PM ET, and we'll ship them the same day.
Price Match Guarantee For Appliance Parts
Price Match Guarantee
We'll match any price offered by our direct competitors on all genuine OEM York replacement parts
Genuine OEM Parts Supplier
Genuine OEM York Replacement Parts
Get peace of mind with the real thing—genuine OEM York parts.

York HVAC Parts and Replacements

York furnaces, air conditioners, and heat pumps are built to run reliably for decades — but when they need repairs, you need OEM parts that match the engineering. Repair Clinic carries genuine York replacement parts for inducer motors, control boards, igniters, pressure switches, and the full range of HVAC parts that keep your heating and cooling running.

York shares parts across its family of brands, including Luxaire, Coleman, and Airtemp. Always confirm your exact model number to ensure compatibility, especially for control boards and igniter assemblies, which vary by product line.

  • Draft inducer motor won't run or makes noise: Check the pressure switch first, then the inducer motor assembly
  • Furnace starts then shuts off within seconds: Flame sensor failure is common; clean first, then replace if needed
  • Furnace won't ignite or produces no heat: Hot surface igniter or gas valve is the likely cause; verify igniter type (SiC vs. SiN) for your model
  • No heat but blower runs: Limit switch, gas valve, or control board issue; pressure switch errors can also prevent ignition
  • Air conditioner compressor won't start: Run capacitor failure is the #1 cause; also check the contactor and start relay

Find your York model number on the furnace or AC unit nameplate, enter it into our parts lookup, and get the exact OEM replacement part with same-day shipping available.

Frequently Asked Questions About York HVAC Parts

What's the difference between York, Luxaire, Coleman, and Airtemp parts?

All four brands are part of the Johnson Controls HVAC family and share engineering platforms and many parts. However, control boards, igniters, and model-specific assemblies can vary. Always use your exact model number to confirm the correct part — cross-referencing within the family is common, but not help ensure. Repair Clinic's lookup tool confirms compatibility across the York family.

How do I find my York model number?

Your York model number is on a nameplate attached to the furnace cabinet (usually near the blower compartment) or on the outdoor AC condenser unit. It starts with letters like "H" or "K" followed by numbers. Write down the full model number — it's needed for ordering the right control board, igniter, or motor assembly. If the nameplate is missing or damaged, Use our online parts finder and visual model lookup to verify compatibility.

York furnace keeps running but produces no heat — what should I check first?

Start with the limit switch and flame sensor. The limit switch is a safety device that cuts off gas if the furnace overheats; if it trips repeatedly, the sensor has likely failed. The flame sensor detects the pilot flame — if it's dirty or cracked, the furnace will ignite briefly then shut off. A quick cleaning with fine steel wool often fixes a flame sensor. If cleaning doesn't help, the sensor or control board needs replacement. For persistent no-heat issues, verify that the gas valve is opening (listen for a clicking sound at ignition), and check the pressure switch for blockages in the drain hose.

Can I use an aftermarket control board instead of an OEM York board?

Not for communicating systems. York Evolution and other Infinity-tier furnaces use proprietary control boards that communicate with thermostats and other equipment. Aftermarket boards won't interface correctly, and you'll lose smart features and error-code diagnostics. For standard, non-communicating furnaces, OEM boards are still the better choice — they're pre-programmed for your model and carry a manufacturer specifications. Repair Clinic stocks genuine York boards for all product lines; enter your model number to find the exact replacement.

Man kneeling next to a wall air conditioning unit, opening the front panel to troubleshoot the air conditioner's problem
Mounting Bracket S1 37319831002 01780320

Order York Furnace Replacement Parts Online

Ordering York furnace replacement parts online is easy with Repair Clinic. Simply search by model number or part number to quickly find the exact replacement parts you need. We offer a full range of York heating parts, York furnace parts, and more, ensuring your system runs smoothly.

Enjoy the convenience of our No-Hassle 365-Day Returns, which allows you to return uninstalled parts within a year of purchase. With our Price Match Guarantee, you can be confident that you're getting competitive pricing on genuine OEM parts for your York furnace.

We offer same-day shipping on orders placed by 9:00 PM ET, so you can get the parts you need as quickly as possible. Whether you're a homeowner or a professional technician, Our online repair library gives you the videos, symptom articles, and step-by-step guides to complete the repair. Find everything you need to keep your system running right, right here.

York HVAC Model Number: Where to Look

On York HVAC equipment, start with the nameplate on the furnace cabinet, often near the blower compartment door. For a York central air conditioner or heat pump, check the exterior nameplate on the outdoor condenser or the label inside its access panel. Copy the complete model number, including letters, numbers, and any suffixes, because similar York units can use different parts. Enter it in the model number search to pull up the parts matched to your unit across the full catalog, not just one part category. Using the exact model filters out incompatible options and helps you order with confidence knowing the fit is right.

Background Image

York Repair Videos and Written Guides

Solid diagnostic work is what makes a York repair go quickly, and Repair Clinic's online library was built for exactly that. Symptom articles, part testing videos, wiring diagrams, and step-by-step written guides give owners and technicians the reference material to isolate the failed part. Look up your model number to match the right OEM part, then follow the installation video.

Related Articles: Washing Machine Parts

What Causes A Washing Machine To Stop Working?

What Causes A Washing Machine To Stop Working?

What causes a washing machine to stop working? Learn common issues like power failures, faulty lid switches, broken drive belts, and more with troubleshooting tips from Repair Clinic.

Why Won't My Washing Machine Start?

Why Won't My Washing Machine Start?

Wondering why your washing machine won't start? Learn common causes like power issues, faulty lid switches, broken timers, and more with expert troubleshooting from Repair Clinic.

What Causes a Washing Machine To Not Spin or Drain?

What Causes a Washing Machine To Not Spin or Drain?

Is your washing machine not spinning or draining? Learn about common issues like clogged drain pumps, faulty lid switches, and worn drive belts, plus expert repair tips from Repair Clinic.