York TG9S080C16MP11 Replacement Parts

Shop replacement repair parts for York Furnace model TG9S080C16MP11

York TG9S080C16MP11 Replacement Parts
Brand:York
Model:TG9S080C16MP11
Product:Furnace
48 results
Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a bestsellerProduct is a manufacturer part
S1-03103010000 Control Board
$172.89

Furnace control board. The control board regulates the supply of power to the furnace components.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-02532625000 Igniter
$84.39

Furnace hot surface igniter kit. The igniter gets very hot and glows bright orange to light the gas burner. If the igniter is cracked or defective, the furnace won’t heat.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-02537499000 Flame Sensor
$71.91

Furnace flame sensor. The flame sensor monitors the burner to detect whether or not a flame is present. If the flame sensor is defective, the furnace may not heat.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-02649692000 Draft Inducer Motor
$273.58

Furnace draft inducer motor. The draft inducer motor draws air into the burner and exhausts it out the flue. If the draft inducer motor is defective, the furnace may not heat.

Skill Level (3)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-02440902000 Blower Motor
$427.36

3/4HP 115Volts 60Hz 11 amp 1060 RPM's 3 Speed Open Enclosure 48Y Frame Single Phase CCW 3.5" Shaft

Go

York TG9S080C16MP11 Problems & Repair Solutions

There are only a handful of issues that crop up with most appliances and equipment. Since 1912, we've learned to recognize the most common York TG9S080C16MP11 problems ― and their solutions. Do any of these look familiar?
Furnace not heating
33 possible causes and potential solutions
Furnace not heating
Furnace is noisy or loud
12 possible causes and potential solutions
Furnace is noisy or loud
Furnace starts then stops
23 possible causes and potential solutions
Furnace starts then stops

Frequently Purchased Together For This Model

Control Board
Gas Burner
Igniter
Run Capacitor

Restore full heating output from your York TG9S080C16MP11 with genuine OEM replacement parts from Repair Clinic. The model decodes as an 80,000 BTU input (080) TG9S furnace, York’s 95% AFUE single-stage condensing series, in a C width cabinet with a 1,600 CFM blower class (C16) and multi-position installation (MP). York, Coleman, and Luxaire share this Johnson Controls platform. Parts replaced most often include the control board, the gas burners, the TG9S080C16MP11 flame sensor, and the blower motor. Check your build on the TG9S080C16MP11 parts list, then shop all York furnace parts.

C16 Cabinet vs B12 at the Same 80,000 BTU Input

This TG9S080C16MP11 furnace has the same burner input as the TG9S080B12MP11, but it pairs that input with a wider C cabinet and a larger 1,600 CFM blower for homes that need more airflow, typically higher cooling tonnage. Combustion parts sized to the 080 input often overlap; blower motors, wheels, and capacitors do not. The TG9S080C16MP11 heat exchanger condenses water in its secondary coil, so the trap and drain need regular cleaning. The TG9S080C16MP11 manual and TG9S080C16MP11 diagram show drain routing and LED codes. For TG9S080C16MP11 repair steps, open the York troubleshooting page.

Most Replaced Parts on This TG9S Furnace

Blower Motor and Capacitor

Weak airflow or limit trips on the C16 blower usually start with the run capacitor. Replace it if it reads more than 5 to 10% below rated value before ordering a blower motor.

Gas Burners and Flame Quality

Rust or debris in burner ports causes ragged flame and rollout trips. Inspect the burners when flame lifts or turns uneven, and replace damaged burners.

Flame Sensor and Igniter

Three short runs before lockout point to a fouled sensor rod; clean it first. No flame with draft proven points to a cracked TG9S080C16MP11 igniter.

Control Board and Pressure Faults

Flush the condensate trap and confirm the TG9S080C16MP11 draft inducer motor reaches full speed before blaming the board. Replace the control board only after testing points to it.

Why Choose Repair Clinic for York TG9S080C16MP11 Parts

  • Genuine York OEM Parts: Components from the platform shared with Coleman and Luxaire. Browse all York furnace parts.
  • Cabinet-Specific Blower Parts: C16 blower motors, wheels, and capacitors are listed separately from the B12 model.
  • Capacitor and Drain First: Test the run capacitor before the motor and flush the trap before any pressure switch.
  • Shop TG9S080C16MP11 Parts Online: In-stock TG9S080C16MP11 replacement parts and TG9S080C16MP11 furnace parts ship the same day with a 365-day return policy.

TG9S080C16MP11 Furnace FAQ

How is the TG9S080C16MP11 different from the TG9S080B12MP11?

Both have an 80,000 BTU input, but the C16 uses a wider cabinet and a 1,600 CFM blower. Blower parts are not shared; many combustion parts are.

What does the control board do?

It sequences the inducer, igniter, gas valve, flame proving, and blower, and reports faults through an LED code.

What makes a TG9S furnace shut down mid-cycle?

A fouled flame sensor is the most common cause. A blocked condensate drain can also trip the pressure switch mid-cycle.

Why is the furnace not heating?

Read the LED code. Common causes are a cracked igniter, fouled flame sensor, blocked drain, or dirty burners.