Coleman DGAA070BDTA Parts & Furnace Repair

Shop replacement repair parts for Coleman Furnace model DGAA070BDTA

Coleman DGAA070BDTA Parts & Furnace Repair
Brand:Coleman
Model:DGAA070BDTA
Product:Furnace
23 results
Skill Level (3)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-03101932002 Control Board
$283.95

Furnace control board. The control board regulates the supply of power to the furnace components. Be sure to check more commonly defective parts before replacing the control board.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-02436226000 Blower Motor
$431.52

Blower motor, 1/3 HP, 115 volts, 60 hertz, 5.6 amps, 1075 RPM, 2 speed

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-02535354000 Flame Sensor
$33.92

Furnace flame sensor. The flame sensor monitors the burner to detect whether or not a flame is present. If the flame sensor is defective, the furnace may not heat.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-37319801821 Draft Inducer Motor
$292.84

Booster assembly often referred to as a furnace draft inducer motor. The draft inducer motor draws air into the burner and exhausts it out the flue. If the draft inducer motor is defective, the furnace may not heat.

Skill Level (1)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
1C26-101S1 Wall Thermostat
$27.22

Thermostat 1C26-101 •1 Heat,1 Cool •24 Volts •Snap-Action •System Switch - Heat, Off, Cool •Fan Switch-Auto, Continuous •Profile-Vertical Rounded •Range 50-90°F •MERCURY FREE

Skill Level (3)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-37319801403 Gas Burner
$362.87

Gas furnace burner assembly with igniter and flame sensor

Go

Coleman DGAA070BDTA Problems & Repair Solutions

There are only a handful of issues that crop up with most appliances and equipment. Since 1912, we've learned to recognize the most common Coleman DGAA070BDTA problems ― and their solutions. Do any of these look familiar?
Furnace not heating
20 possible causes and potential solutions
Furnace not heating
Furnace is noisy or loud
8 possible causes and potential solutions
Furnace is noisy or loud
Furnace starts then stops
13 possible causes and potential solutions
Furnace starts then stops

Frequently Purchased Together For This Model

Control Board
Limit Switch
Blower Motor
Tube

Get your Coleman DGAA070BDTA heating reliably again with genuine OEM replacement parts from Repair Clinic. The 070 code identifies a 70,000 BTU input rating in Coleman’s DGAA gas furnace series, a Coleman Evcon line now supported by Johnson Controls alongside York and Luxaire, and common in manufactured home installations. The parts that wear most are the DGAA070BDTA draft inducer motor, the igniter, the flame sensor, and the control board. Check your build on the DGAA070BDTA parts list, then shop the complete Coleman furnace parts catalog.

DGAA070BDTA Furnace Details and the BDTB Revision

This DGAA070BDTA shares its 70,000 BTU cabinet with the later DGAA070BDTB. The final letter marks a production revision: most ignition, sensing, and blower parts carry across both, but control boards and pressure switches can change between runs, so match those to the exact suffix on your data plate. The furnace runs a conventional sequence: the inducer purges the DGAA070BDTA heat exchanger, the pressure switch proves draft, the igniter heats, the gas valve opens, and the flame sensor confirms combustion. A failure at any stage shows as an LED code on the board, documented in the DGAA070BDTA manual and on the DGAA070BDTA diagram. For DGAA070BDTA repair steps by symptom, open the model troubleshooting guide.

Most Replaced Coleman DGAA070BDTA Furnace Parts

Draft Inducer Motor and Pressure Switch Faults

The inducer vents combustion gases and creates the draft the pressure switch must sense. A motor with worn bearings hums or grinds, starts slowly, and finally fails to close the switch. If the code points to the pressure circuit, inspect the vent and tubing, then confirm the motor reaches full speed before buying parts. Replacement inducer motors are listed here.

Igniter Cracks and No-Heat Starts

When the inducer runs and the switch closes but the burner never lights, inspect the DGAA070BDTA igniter. Hot surface elements crack after years of thermal cycling and stop reaching ignition temperature, and repeated failed starts stress the gas valve and board. Hold the new igniter only by its base.

Flame Sensor and Brief Burner Runs

A burner that lights and shuts off within seconds points to the DGAA070BDTA flame sensor. Oxide on the rod lowers the signal below the board’s threshold. Clean it with fine steel wool, and replace the flame sensor if lockouts continue.

Control Board Diagnosis

Count the LED flashes before touching any part, since the code names the failed stage. Replace the board only after the igniter, flame sensor, and pressure switch test good, and order the version that matches your BDTA suffix from the control board filter.

Why Choose Repair Clinic for Coleman DGAA070BDTA Parts

  • Genuine Coleman and Johnson Controls Parts: OEM components shared with York and Luxaire equipment. Browse all Coleman furnace parts.
  • Suffix-Matched Boards: BDTA and BDTB control boards are listed separately, while shared ignition parts are flagged.
  • Sequence-Based Diagnosis: Read the code, clean the flame sensor, test the igniter and pressure switch, then evaluate the board.
  • Shop DGAA070BDTA Parts Online: In-stock DGAA070BDTA replacement parts and DGAA070BDTA furnace parts ship the same day with a 365-day return policy.

Coleman DGAA070BDTA Furnace FAQ

Are DGAA070BDTA and DGAA070BDTB parts interchangeable?

Most ignition, sensing, and blower parts are shared. Control boards and pressure switches can differ between the two revisions, so match those to the exact suffix on your data plate.

Why won’t my furnace start?

Read the LED code first. The most common causes are a cracked igniter, a pressure switch that never closes because of a slow inducer or blocked vent, or a control board fault.

What are signs of a failing draft inducer motor?

Humming, grinding, or squealing at startup, slow spin-up, and pressure switch lockouts before the igniter energizes. Check the vent and tubing before replacing the motor.

Where can I find the parts list and manual?

Open the diagrams and manuals tab on this page. The exploded diagrams group DGAA070BDTA parts by burner, blower, and electrical sections, and the manual includes wiring and fault codes.