Coleman Furnace DGAA090BDTA Parts

Shop replacement repair parts for Coleman Furnace model DGAA090BDTA

Coleman Furnace DGAA090BDTA Parts
Brand:Coleman
Model:DGAA090BDTA
Product:Furnace
23 results
Skill Level (3)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-03101932002 Control Board
$283.95

Furnace control board. The control board regulates the supply of power to the furnace components. Be sure to check more commonly defective parts before replacing the control board.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-02436226000 Blower Motor
$431.52

Blower motor, 1/3 HP, 115 volts, 60 hertz, 5.6 amps, 1075 RPM, 2 speed

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-02535354000 Flame Sensor
$33.92

Furnace flame sensor. The flame sensor monitors the burner to detect whether or not a flame is present. If the flame sensor is defective, the furnace may not heat.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-37319801821 Draft Inducer Motor
$292.84

Booster assembly often referred to as a furnace draft inducer motor. The draft inducer motor draws air into the burner and exhausts it out the flue. If the draft inducer motor is defective, the furnace may not heat.

Skill Level (1)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
1C26-101S1 Wall Thermostat
$27.22

Thermostat 1C26-101 •1 Heat,1 Cool •24 Volts •Snap-Action •System Switch - Heat, Off, Cool •Fan Switch-Auto, Continuous •Profile-Vertical Rounded •Range 50-90°F •MERCURY FREE

Skill Level (3)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-37319801403 Gas Burner
$362.87

Gas furnace burner assembly with igniter and flame sensor

Go

Coleman DGAA090BDTA Problems & Repair Solutions

There are only a handful of issues that crop up with most appliances and equipment. Since 1912, we've learned to recognize the most common Coleman DGAA090BDTA problems ― and their solutions. Do any of these look familiar?
Furnace not heating
20 possible causes and potential solutions
Furnace not heating
Furnace is noisy or loud
8 possible causes and potential solutions
Furnace is noisy or loud
Furnace starts then stops
13 possible causes and potential solutions
Furnace starts then stops

Frequently Purchased Together For This Model

Control Board
Limit Switch
Limit Switch
Blower Motor

Maintain reliable heat from your Coleman DGAA090BDTA downflow gas furnace with genuine OEM replacement parts from Repair Clinic. The DGAA090BDTA is a 90,000 BTU downflow gas furnace for manufactured and mobile home installations, the higher-output sibling of the DGAA077BDTA on the same downflow platform. Coleman is a Nordyne brand channel product; the DGAA090BDTA shares its manufacturing platform with Nordyne’s downflow manufactured home furnace line with fully interchangeable service parts. Parts most frequently replaced include the inducer booster assembly, hot surface igniter, control board, pressure switch, and flame sensor. Browse the full Nordyne furnace parts catalog filtered by DGAA090BDTA.

DGAA090BDTA vs DGAA077BDTA: Higher Output Requires Output-Class Matched Components

The DGAA090BDTA and DGAA077BDTA share the same downflow cabinet platform and many service components including the hot surface igniter, flame sensor, and limit switches. The inducer motor and pressure switch, however, are calibrated to each model’s specific BTU output; a 077-class inducer installed in a 090-class furnace does not generate sufficient draft to close the 090-rated pressure switch. Never cross-substitute inducer or pressure switch components between these two models. In the downflow orientation the inducer is positioned near the top of the cabinet and draws combustion gases upward, making it particularly vulnerable to moisture-induced bearing wear. For downflow-specific diagnostics, visit the Coleman furnace troubleshooting section.

Most Replaced Parts on the Coleman DGAA090BDTA

Draft Inducer Booster Assembly for the DGAA090BDTA

The DGAA090BDTA inducer must handle the higher combustion gas volume of this 90,000 BTU model, requiring an assembly rated for the 090 output class. In the downflow orientation, moisture from combustion condenses in the inducer housing and accelerates bearing wear; grinding at inducer startup is almost always bearing failure and warrants complete assembly replacement. Browse Nordyne furnace inducer motor parts and confirm the 090 output class designation before ordering.

DGAA090BDTA Hot Surface Igniter

The igniter is positioned in the burner box at the top of the downflow cabinet, accessible from the upper access panel. At 90,000 BTU this furnace cycles aggressively in extreme cold, accumulating igniter thermal cycles at a higher rate per season than the 077 model and shortening igniter service life accordingly. An open-circuit igniter causes the control board to lock out after two or three failed ignition attempts without the gas valve ever activating. Browse Nordyne furnace igniter parts.

DGAA090BDTA Control Board

The control board sequences the 90,000 BTU ignition cycle and blower timing specific to the downflow platform. The board used in the DGAA090BDTA may differ from the DGAA077BDTA board in blower timing parameters for the larger output. Confirm the part number from the installed board’s data tag before ordering; upflow Nordyne boards are not interchangeable with downflow DGAA boards even at the same BTU rating. Browse Nordyne furnace control board parts.

DGAA090BDTA Pressure Switch

The pressure switch is calibrated for the higher draft produced by the 090 inducer at full combustion gas volume; a switch from the DGAA077BDTA has a lower calibration point and must not be substituted. Before replacing the switch, inspect the pressure hose for kinks behind insulation and check the condensate drain tube; a clear, intact hose with a switch that still reads open at normal operating draft confirms a failed switch diaphragm.

DGAA090BDTA Flame Sensor

The flame sensor monitors the burner in the downflow assembly; a furnace that lights and shuts off within two to five seconds of ignition is showing the flame sensor symptom. Annual light cleaning with fine steel wool is the most cost-effective preventive maintenance step for extending sensor service life on the DGAA platform. Browse Nordyne furnace flame sensor parts.

Coleman DGAA090BDTA Parts at Repair Clinic

  • Genuine Coleman OEM Parts for the DGAA090BDTA 90,000 BTU Downflow Platform: Inducer assembly, igniter, pressure switch, and flame sensor differentiated from the DGAA077BDTA where inducer and switch specifications differ. Browse the full Nordyne furnace parts catalog.
  • Output-Class Component Matching: The inducer motor and pressure switch for the DGAA090BDTA are specified for the 090 combustion gas volume; our listings prevent cross-substitution errors with 077-class components.
  • DGAA090BDTB and DGAA090 Variant Coverage: Parts for the BDTB revision and related DGAA090 variants are also available with model-specific filtering.
  • 365-Day Returns and Fast Shipping: All DGAA090BDTA parts ship promptly. The Coleman furnace troubleshooting section covers downflow DGAA platform diagnostics.

Coleman DGAA090BDTA Furnace Parts FAQ

How does the DGAA090BDTA differ from the DGAA077BDTA?

The DGAA090BDTA delivers 90,000 BTU input vs the DGAA077BDTA at 77,000 BTU. The higher output requires a larger inducer and a pressure switch calibrated for the 090 combustion gas volume; these components must not be cross-substituted between the two models. The igniter, flame sensor, and many limit switches are shared across both models.

Why does the inducer on my Coleman DGAA090BDTA grind at startup?

Grinding at inducer startup on the DGAA platform is almost always bearing failure from moisture exposure in the downflow orientation, where the inducer housing is near the top of the cabinet and condensate accumulates near the bearing. Replace the complete inducer assembly rather than attempting to service the bearing alone; a seized inducer prevents the pressure switch from closing and shuts down the furnace entirely.

What is the BTU output of the Coleman DGAA090BDTA?

The DGAA090BDTA delivers 90,000 BTU input capacity. The DGAA designation identifies a Coleman downflow gas furnace for manufactured home installation; the 090 identifies the BTU class. This model is appropriate for larger manufactured homes where the DGAA077BDTA’s 77,000 BTU output would be insufficient during extreme cold.

Is the Coleman DGAA090BDTA HUD-compliant for manufactured homes?

Yes. The DGAA090BDTA is listed and designed for installation in HUD-code manufactured homes. The downflow air distribution design, combustion air sourcing, and venting configuration all comply with HUD standards for factory-built housing.