Coleman Furnace DGAT070BDD Parts

Shop replacement repair parts for Coleman Furnace model DGAT070BDD

icons/furnace
Brand:Coleman
Model:DGAT070BDD
Product:Furnace
27 results
Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-7624A3591 Limit Switch
$27.69

Upper limit switch 180° manual reset
manufacture approved alternate for
this limit switch part# S1-7990-3591

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-7966-311P Blower Motor
$310.74

Furnace blower motor. This single-phase motor has the following specifications:

Horsepower: 1/6
Voltage: 115
Rated Amps: 3
Hertz: 60
RPM: 1050
Speeds: 1
Rotation: CCW
Frame: 42
Enclosure: Open

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-7990-6451 Draft Inducer Motor
$507.43

Booster assembly. The booster assembly draws air into the burner and exhausts it out the flue. If the draft inducer motor is defective, the furnace may not heat.

Skill Level (1)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-7660-3401 Air Filter
$47.32

19-3/8" x 35-3/4" x 1/4" Heating Blower Foam 'Pre-Filter'

Skill Level (1)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
1C26-101S1 Wall Thermostat
$27.22

Thermostat 1C26-101 •1 Heat,1 Cool •24 Volts •Snap-Action •System Switch - Heat, Off, Cool •Fan Switch-Auto, Continuous •Profile-Vertical Rounded •Range 50-90°F •MERCURY FREE

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
S1-7990-317P/A Draft Inducer Motor
$260.12

Furnace draft inducer motor. The draft inducer motor draws air into the burner and exhausts it out the flue. If the draft inducer motor is defective, the furnace may not heat.

Go

Coleman DGAT070BDD Problems & Repair Solutions

There are only a handful of issues that crop up with most appliances and equipment. Since 1912, we've learned to recognize the most common Coleman DGAT070BDD problems ― and their solutions. Do any of these look familiar?
Furnace not heating
19 possible causes and potential solutions
Furnace not heating
Furnace is noisy or loud
11 possible causes and potential solutions
Furnace is noisy or loud
Furnace starts then stops
13 possible causes and potential solutions
Furnace starts then stops

Frequently Purchased Together For This Model

Limit Switch
Limit Switch
Blower Motor
Gas Valve Assembly

Keep your Coleman DGAT070BDD heating through the season with genuine OEM replacement parts from Repair Clinic. The 070 code identifies a 70,000 BTU input in Coleman’s DGAT series, a Coleman Evcon downflow furnace line built for manufactured homes and now supported by Johnson Controls alongside York and Luxaire. Parts replaced most often include the DGAT070BDD igniter, the flame sensor, the draft inducer motor, and the control board. Check your build on the DGAT070BDD parts list, then browse all Coleman furnace parts.

DGAT070BDD Revisions and Downflow Layout

Later suffixes of this 70,000 BTU DGAT, such as BDE and BDF, follow the BDD; ignition parts are typically shared across them, while control boards should be matched to the suffix on your data plate. The DGAT is a separate series from the Coleman DGAA070BDTA, so do not assume parts cross between them. In the downflow layout, heated air leaves the bottom of the cabinet into the floor ducts and the burner section sits above. The DGAT070BDD heat exchanger depends on full blower airflow to stay below its limit. The DGAT070BDD manual and DGAT070BDD diagram show codes and wiring. For DGAT070BDD repair steps, open the model troubleshooting guide.

Most Replaced Parts on This Coleman Furnace

Igniter

Test the hot surface element for continuity with power off; an open reading confirms failure. Replace the igniter before suspecting the gas valve or board.

Flame Sensor

A burner that lights and shuts off within seconds has a fouled DGAT070BDD flame sensor. Clean it yearly with fine steel wool and replace the sensor if lockouts continue.

Draft Inducer Motor

The DGAT070BDD draft inducer motor clears combustion gases before ignition. Grinding at startup means worn bearings; replace the inducer motor before it seizes and leaves the home without heat.

Blower Motor and Capacitor

Slow starts or weak airflow usually begin with a weak run capacitor. Test it against its rated value before replacing the PSC blower motor.

Why Choose Repair Clinic for Coleman DGAT070BDD Parts

  • Genuine Coleman and Johnson Controls Parts: OEM components shared with York and Luxaire equipment. Shop all Coleman furnace parts.
  • Revision Matching: DGAT070BDD parts such as control boards are listed separately from later BDE and BDF suffixes.
  • Capacitor Before Motor: Test the run capacitor before replacing the blower motor.
  • Shop DGAT070BDD Parts Online: In-stock DGAT070BDD replacement parts and DGAT070BDD furnace parts ship the same day with a 365-day return policy.

DGAT070BDD Furnace FAQ

What BTU input does this furnace have?

The 070 code identifies a 70,000 BTU input. Confirm the exact rating on the data plate inside the cabinet.

Is the DGAT070BDD the same as the BDE or BDF?

They are successive revisions of the same size. Ignition parts are typically shared, but match the control board to your exact suffix.

Why does my furnace ignite and then shut off within seconds?

A fouled flame sensor is the usual cause. Clean the rod and replace it if the pattern continues.

How do I read the DGAT LED fault code?

Count the LED flashes and match the pattern to the chart inside the blower compartment door.