Restore your AEPF426016CA air handler running reliably with genuine OEM replacement parts from Repair Clinic. The AEPF426016CA is a three-and-a-half-ton residential air handler. The AEPF designation identifies a Goodman upflow cased air handler series. The 4260 capacity coding identifies three-and-a-half-ton capacity within the AEPF platform. Goodman, Daikin, and Amana are related brands under the same parent company. The blower motor, run capacitor, and control board account for the majority of AEPF426016CA service calls. Repair Clinic stocks genuine Goodman OEM parts for the AEPF426016CA including the Goodman air handler blower motor parts, Goodman air handler capacitor parts, Goodman air handler control board parts, and Goodman air handler drain pan parts. Browse the Goodman air handler parts catalog filtered by AEPF426016CA for the complete parts inventory.
AEPF426016CA: Three-And-A-Half-Ton Residential Air Handler Service
The blower motor and run capacitor on the AEPF426016CA are sized for three-and-a-half-ton airflow requirements. In heat pump applications the blower runs year-round, making annual run capacitor testing especially important. Annual condensate drain line flushing prevents the overflow that causes the most common water leak complaint.
Most Replaced Parts on the AEPF426016CA
Blower Motor for the AEPF426016CA
In heat pump applications this motor runs year-round. Test the run capacitor before ordering a replacement motor.
Run Capacitor for the AEPF426016CA
A reading more than 10% below the rated microfarad value causes the blower motor to run hot at reduced airflow.
Control Board for the AEPF426016CA
Confirm the full model designation from the data plate before ordering. A board fault typically presents as the unit not responding to thermostat commands.
Drain Pan for the AEPF426016CA
Clear the drain line completely before replacing the pan.
Why Choose Repair Clinic for AEPF426016CA Parts
- Genuine Goodman AEPF OEM Components: Three-and-a-half-ton blower motors, run capacitors, and control boards confirmed for the AEPF426016CA Goodman air handler parts.
- R-410A Puron Platform: The AEPF426016CA refrigerant circuit uses R-410A. Refrigerant circuit service requires EPA 608 certified technicians.
- Heat Pump Year-Round Blower Hours: In heat pump applications the blower runs year-round, making annual run capacitor testing especially important.
- 365-Day Returns: Return any uninstalled part within a full year of purchase with no restocking fees.
AEPF426016CA Air Handler Parts FAQ
What is the AEPF426016CA and what ton size is it?
The AEPF426016CA is a three-and-a-half-ton residential air handler. The AEPF designation identifies a Goodman upflow cased air handler series. The 4260 capacity coding identifies three-and-a-half-ton capacity within the AEPF platform. Goodman, Daikin, and Amana are related brands under the same parent company.
Why is my AEPF426016CA not circulating air?
No airflow is most commonly caused by a failed run capacitor preventing the blower motor from starting, a tripped circuit breaker, or a clogged air filter. Check the filter and breaker before testing the capacitor and motor.
How does the Goodman AEPF426016CA differ from the ARUF036-00A-1?
The AEPF426016CA is a cased air handler while the ARUF036-00A-1 is an uncased upflow air handler. The AEPF is a three-and-a-half-ton cased unit requiring no additional field enclosure, while the uncased ARUF requires a field-supplied cabinet.
Why is my AEPF426016CA leaking water?
Water leaking is most commonly caused by a clogged condensate drain line causing the drain pan to overflow. Clear the drain line completely before replacing the drain pan.