Goodman GMP075-3 Furnace Parts

Shop replacement repair parts for Goodman Furnace model GMP075-3

icons/furnace
Brand:Goodman
Model:GMP075-3
Product:Furnace
38 results
Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a bestsellerProduct is a manufacturer part
0130F00010S Flame Sensor
$32.34

Furnace flame sensor. The flame sensor monitors the burner to detect whether or not a flame is present. If the flame sensor is defective, the furnace may not heat.

Skill Level (3)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
B1809913S Control Board
$234.01

Furnace control board. The control board regulates the supply of power to the furnace components. Be sure to check more commonly defective parts before replacing the control board.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
B1340021S Blower Motor
$287.57

Blower, Motor - 1/3HP 115 Volts 60 Hz 5.1 amp 1050 RPM's 3 Speed Open Enclosure Single Phase CCW 3.5" Shaft

Skill Level (3)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
B1859005S Draft Inducer Motor
$277.37

Ventor motor assembly for GMP series. The draft inducer/ventor motor draws air into the burner and exhausts it out the flue. If the draft inducer motor is defective, the furnace may not heat.

Go

Goodman GMP075-3 Problems & Repair Solutions

There are only a handful of issues that crop up with most appliances and equipment. Since 1912, we've learned to recognize the most common Goodman GMP075-3 problems ― and their solutions. Do any of these look familiar?
Furnace not heating
27 possible causes and potential solutions
Furnace not heating
Furnace is noisy or loud
9 possible causes and potential solutions
Furnace is noisy or loud
Furnace starts then stops
16 possible causes and potential solutions
Furnace starts then stops

Frequently Purchased Together For This Model

Flame Sensor
Transformer
Gas Valve Assembly
Igniter

Keep your Goodman GMP075-3 heating at full capacity with genuine OEM replacement parts from Repair Clinic. The model decodes as a 75,000 BTU input, 80% AFUE single-stage gas furnace with a 3-ton blower, the -3 suffix, in Goodman’s non-condensing GMP series. Goodman shares its engineering with Amana and Daikin, so many components carry across those brands. The parts replaced most often are the GMP075-3 control board, the inducer and blower motors, the hot surface igniter, and the flame sensor. Confirm your build on the parts diagram, then browse the complete Goodman furnace parts catalog.

GMP075-3 Specs, Revisions, and the MPGA075B3

The GMP075-3 specs place it in the original GMP generation: 80% AFUE, single-stage burner, standard B-vent exhaust, and a PSC blower motor. It is not interchangeable with the later GMPN generation for blower components, and it shares nothing with condensing GMH95 venting or condensate parts. The GMP075-3 rev B designation marks a revised production run; control boards and harnesses can change between revisions, while igniters, flame sensors, and blower motors are usually shared. Shoppers comparing the MPGA075B3 should treat it as a separate designation in the same 75,000 BTU, 3-ton class: open its own list for MPGA075B3 parts rather than assuming a match. The GMP075-3 manual includes the LED fault code chart. For symptom guidance, see the Goodman GMP075 3 repair help page.

Where the Goodman GMP075-3 Fails and How to Diagnose It

Control Board Revision Matching and Relay Faults

The board sequences the heat cycle and reports faults through an LED. Confirm whether your unit is the standard or rev B build from the data label before ordering, because a mismatched board can create ignition timing problems. A furnace that completes pre-purge and igniter warm-up but never opens the gas valve often has a failed valve relay on the board rather than a bad valve. Read the code first, then shop control boards.

Blower Motor and Capacitor Testing

The GMP075-3 blower motor is a PSC motor matched to the 3-ton blower assembly; the GMP075-4 uses a 4-ton assembly and its motor is not a substitute. Weak airflow or a humming motor should start with the run capacitor: replace it if it reads more than 5 to 10% below its rated microfarad value, matching the value printed on the installed capacitor. Replace the blower motor only if the problem remains with a good capacitor.

Inducer Motor Bearing Wear

The inducer draws combustion air through the heat exchanger and pushes it out the B-vent before ignition. Worn bearings squeal or grind during pre-purge and eventually stall the motor, so draft falls below the pressure switch setting and the furnace locks out before the igniter stage. An inducer that runs noisily and then locks out points to the motor rather than the switch. Replacement inducer motors are on this page.

Igniter and Flame Sensor Pairing

A fractured silicon nitride igniter glows unevenly and fails to light cold burners; handle replacements by the ceramic base, since skin oils shorten element life. If the burner lights, runs 3 to 7 seconds, and shuts off three times before lockout, the flame sensor is contaminated. Clean it with fine emery cloth, and replace it if the pattern persists.

Why Choose Repair Clinic for Goodman GMP075-3 Parts

  • Goodman, Amana, and Daikin OEM Parts: Genuine components from the shared Goodman platform. Shop the full Goodman furnace parts catalog.
  • Revision-Aware Listings: Standard and rev B control boards are separated, preventing timing faults after installation.
  • Capacitor Before Motor: Test the run capacitor before replacing a GMP075-3 blower motor; the symptoms are identical and the capacitor costs far less.
  • Fast Shipping in Heating Season: In-stock GMP075-3 parts ship the same day, with a 365-day return policy and model troubleshooting help.

Goodman GMP075-3 Furnace FAQ

What is the difference between the GMP075-3 and the GMP075-3 rev B?

Rev B is a revised production run of the same 75,000 BTU furnace. The revision mainly affects the control board and sometimes the wiring harness. Igniters, flame sensors, and blower motors are usually shared. Confirm the revision on the data label before ordering a board.

Can I use a GMPN blower motor in this furnace?

No. The GMP and GMPN are different platform generations with different blower assemblies. Match the replacement to the 3-ton GMP assembly, and test the run capacitor before replacing the motor.

Are MPGA075B3 parts the same as GMP075-3 parts?

Do not assume so. The MPGA075B3 is a separate designation in the same 75,000 BTU, 3-ton class. Some ignition parts may overlap, but check the parts list for the exact model on your data plate before ordering.

When should the gas valve be replaced instead of the board?

Replace the valve only when the igniter glows correctly, the board is confirmed to be sending 24 volts to the valve, and no gas reaches the burner. A failed board relay causes the same no-fire symptom.