0130F00010S Flame Sensor
$32.34

Furnace flame sensor. The flame sensor monitors the burner to detect whether or not a flame is present. If the flame sensor is defective, the furnace may not heat.

Skill Level (3)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
B1809913S Control Board
$234.01

Furnace control board. The control board regulates the supply of power to the furnace components. Be sure to check more commonly defective parts before replacing the control board.

Skill Level (3)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
B1859005S Draft Inducer Motor
$277.37

Ventor motor assembly for GMP series. The draft inducer/ventor motor draws air into the burner and exhausts it out the flue. If the draft inducer motor is defective, the furnace may not heat.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
B1340020S Blower Motor
$277.38

Direct drive motor, 1/2HP, 115 Volts, 60 Hertz, 7 amps, 1075 RPM's, 3 Speed, Open Enclosure, 48Y Frame, Single Phase, CCW, 4" Shaft

Go

Goodman GMP100-4 Problems & Repair Solutions

There are only a handful of issues that crop up with most appliances and equipment. Since 1912, we've learned to recognize the most common Goodman GMP100-4 problems ― and their solutions. Do any of these look familiar?
Furnace not heating
26 possible causes and potential solutions
Furnace not heating
Furnace is noisy or loud
9 possible causes and potential solutions
Furnace is noisy or loud
Furnace starts then stops
15 possible causes and potential solutions
Furnace starts then stops

Frequently Purchased Together For This Model

Flame Sensor
Transformer
Gas Valve Assembly
Igniter

Restore steady, reliable heat to your Goodman GMP100-4 Furnace with genuine OEM replacement parts from Repair Clinic. This furnace belongs to Goodman’s earlier GMP series of 80% AFUE single stage gas furnaces, rated at 100,000 BTU input with a blower sized for up to 4 tons of cooling airflow. Many of these units have been in service for well over a decade, and age related wear on the ignition and draft systems accounts for most repairs. Commonly replaced parts include the hot surface igniter, flame sensor, draft inducer motor, pressure switch, limit switch, and control board. Browse the complete parts catalog for this model and check the parts diagram to confirm fit before ordering.

Understanding Your GMP100-4 Furnace

Goodman’s GMP series predates the current GMS8 and GMVC lines, and the number on this unit is straightforward to read: 100 identifies the 100,000 BTU input rating, and the 4 indicates nominal blower capacity in tons. Because the series has been out of production for some time, several original components have been superseded by updated replacement parts or universal kits approved for this furnace. A replacement may look slightly different from the original yet still be the correct part, so rely on the model match rather than appearance alone. The ignition sequence is the same as on newer Goodman furnaces. The draft inducer starts, the pressure switch proves venting, the hot surface igniter heats, the gas valve opens, and the flame sensor confirms combustion before the blower comes on. This non-condensing furnace vents through metal B-vent and has no condensate trap. On an older furnace, inspect the heat exchanger carefully during each annual service, because metal fatigue after many years of heating cycles can lead to cracks that require professional evaluation and may justify replacing the furnace rather than repairing it.

Most Replaced Parts on the GMP100-4 Furnace

Hot Surface Igniter Replacement

The igniter is the most frequently replaced part on older Goodman furnaces, because its element becomes brittle after years of heating and cooling. When it cracks, the inducer runs and the board attempts ignition, but the burners never light and the furnace locks out after several tries. Original igniters on this series have often been superseded, so the replacement may have a different shape or connector adapter. Inspect the old element for cracks, test its resistance, and avoid touching the new element during installation.

Flame Sensor Short Cycling

Short cycling, where the burners light and then shut off after a few seconds, points to a weak flame signal. Years of combustion build an oxide layer on the sensor rod that the control board can no longer read through. Clean the rod with fine steel wool and make sure the mounting bracket is tight and free of corrosion, since a poor ground produces the same symptom. Replace the sensor if cleaning gives only temporary relief or the insulator is cracked or loose.

Draft Inducer Motor and Pressure Switch

On a furnace of this age, inducer bearings are a common wear point. A loud startup, a motor that hums but does not spin freely, or a pressure switch fault code are typical symptoms. Inspect the pressure hose for cracks and the inducer port for blockage before replacing the switch, and confirm the vent pipe is intact and clear. If the inducer is noisy or slow to reach speed, replace it, since a failing motor can prevent the pressure switch from closing reliably.

Limit Switch and Heat Exchanger Overheating

The limit switch opens when the heat exchanger gets too hot, shutting down the burners to protect the furnace. Repeated trips usually mean airflow is restricted by a dirty filter, blocked return, closed registers, or a dirty blower wheel. A limit switch that has tripped many times can also weaken and open early, so replace it only after correcting airflow. Persistent overheating on an older furnace stresses the heat exchanger, so have it inspected for cracks if limit trips have been frequent.

Why Choose Repair Clinic for GMP100-4 Parts?

  • Correct Parts for Older Models: We identify the current OEM or approved replacement for components that Goodman has superseded on the GMP series, so you get a part that fits and works.
  • Detailed Parts Diagrams: Model specific diagrams and manuals show where each component mounts, which is especially helpful on older furnaces where labels may be worn or missing.
  • Fast Shipping: Most in-stock parts ship the same business day so you can get your heat back quickly.
  • Easy Returns and Support: Eligible parts are covered by our 365 day return policy, and our team can help you confirm the right part before you order.

Frequently Asked Questions

Why does my replacement igniter look different from the original?

Many original parts on Goodman’s GMP series have been superseded by updated versions. The new igniter may use a different shape or include a wiring adapter, but it is approved as the correct replacement for this furnace.

What size is this Goodman furnace?

The 100 in the model number indicates a 100,000 BTU input rating, and the 4 indicates a blower sized for about 4 tons of cooling airflow. At 80% AFUE, it delivers roughly 80,000 BTU of usable heat.

Why does my furnace start and then shut off after a few seconds?

This short cycling is usually caused by a dirty flame sensor or a poor ground at its mounting bracket. Clean the sensor rod and tighten the bracket before replacing the sensor or control board.

Is it worth repairing an older Goodman furnace?

Replacing igniters, sensors, inducers, and switches is usually cost effective. A cracked heat exchanger is a different matter, so have it inspected professionally, since that damage often makes replacing the furnace the better option.