Goodman GMPN080-4 Parts

Shop replacement repair parts for Goodman Furnace model GMPN080-4

icons/furnace
Brand:Goodman
Model:GMPN080-4
Product:Furnace
50 results
Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a bestsellerProduct is a manufacturer part
0130F00010S Flame Sensor
$32.34

Furnace flame sensor. The flame sensor monitors the burner to detect whether or not a flame is present. If the flame sensor is defective, the furnace may not heat.

Skill Level (3)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
B1809913S Control Board
$234.01

Furnace control board. The control board regulates the supply of power to the furnace components. Be sure to check more commonly defective parts before replacing the control board.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
B1340020S Blower Motor
$277.38

Direct drive motor, 1/2HP, 115 Volts, 60 Hertz, 7 amps, 1075 RPM's, 3 Speed, Open Enclosure, 48Y Frame, Single Phase, CCW, 4" Shaft

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
B2833001S Draft Inducer Motor
$326.33

Furnace draft inducer motor. The draft inducer motor draws air into the burner and exhausts it out the flue. If the draft inducer motor is defective, the furnace may not heat.

Skill Level (3)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
ICM280 Control Board
$193.11

Furnace control board. The control board regulates the supply of power to the furnace components. Be sure to check more commonly defective parts before replacing the control board.

Go

Goodman GMPN080-4 Problems & Repair Solutions

There are only a handful of issues that crop up with most appliances and equipment. Since 1912, we've learned to recognize the most common Goodman GMPN080-4 problems ― and their solutions. Do any of these look familiar?
Furnace not heating
23 possible causes and potential solutions
Furnace not heating
Furnace is noisy or loud
9 possible causes and potential solutions
Furnace is noisy or loud
Furnace starts then stops
16 possible causes and potential solutions
Furnace starts then stops

Frequently Purchased Together For This Model

Flame Sensor
Transformer
Gas Valve Assembly
Igniter

Get dependable heating from your Goodman GMPN080-4 furnace with genuine OEM replacement parts from Repair Clinic. The GMPN080-4 is an 80,000 BTU single-stage upflow gas furnace built on a four-ton blower platform, marketed as a Northern-climate variant of the GMP080 series with airflow calibrations suited to colder regional installations; the GMPN designation indicates a Northern-climate variant, and most service parts are shared between GMP080 and GMPN080-4. Goodman, Amana, and Daikin are the same manufacturing family sharing this platform. Parts most frequently replaced include the hot surface igniter B1401018S/0230K00001, control board B1809913S, flame sensor 0130F00010, inducer motor B2833001S, and blower motor B1340020S. Browse the full Goodman furnace parts catalog.

Goodman GMPN080-4: 80,000 BTU Northern-Climate Four-Ton Platform, GMP080 Shared Components, and Longer-Vent Inducer Context

The GMPN080-4 shares most of its service components with the GMP080-4 and GMP100-4 siblings on the same Goodman platform. The key differences lie in the blower motor speed tap configuration and airflow-specific calibrations for Northern-climate use. Northern-climate installations with longer venting runs place additional back-pressure on the inducer motor B2833001S, which can accelerate bearing wear compared to short-run installations; inspect the inducer for bearing noise annually in installations with vent runs exceeding 20 feet. For fault code interpretation for the B1809913S control board, visit the Goodman furnace troubleshooting section.

Most Replaced Parts on the Goodman GMPN080-4

Hot Surface Igniter B1401018S / 0230K00001

The GMPN080-4 originally shipped with the B1401018S silicon carbide igniter. Goodman’s current OEM replacement is the 0230K00001 silicon nitride mini igniter, rated seven times more durable than the carbide original. A failed igniter causes the board to time out without a confirmed flame and lock out the furnace; handle the element only by its ceramic base during installation to avoid thermal hot spots from skin oils. Browse Goodman furnace igniter parts.

GMPN080-4 Control Board B1809913S

The B1809913S is the 9-pin HSI control board managing ignition, blower delays, and safety switch monitoring on the GMPN080-4. The LED flash pattern stores the most recent fault in a two-digit blink code; read and document the code before replacing any component. A three-flash code indicating ignition failure points to the igniter or flame sensor, not the board, in the majority of GMPN080-4 service calls. Browse Goodman furnace control board parts.

GMPN080-4 Draft Inducer Motor B2833001S

Goodman part B2833001S is the draft inducer motor for the GMPN080-4 platform, sized to draw combustion gases through the heat exchanger before the main burner ignites. Bearing wear presents as a grinding sound during the pre-purge phase; Northern-climate installations with longer venting runs place additional back-pressure on the inducer and can accelerate bearing wear. Browse Goodman furnace inducer motor parts.

GMPN080-4 Blower Motor B1340020S and Capacitor CAP100000370VAS

The B1340020S is a 1/2 HP, 1075 RPM, 3-speed PSC motor serving the GMPN080-4 four-ton blower assembly. The run capacitor for this motor is CAP100000370VAS. A capacitor that has drifted outside its rated microfarad value causes the motor to start slowly or run at reduced speed, triggering limit switch trips from insufficient airflow. Always test the capacitor before ordering a replacement motor. Browse Goodman furnace blower motor parts.

GMPN080-4 Flame Sensor 0130F00010

The flame sensor 0130F00010 confirms sustained combustion to the B1809913S control board. Surface oxidation on the rod is the most common cause of short-cycling lockouts; cleaning the rod with fine steel wool can provide temporary relief, but a worn or corroded rod should be replaced for lasting results. Browse Goodman furnace flame sensor parts.

Goodman GMPN080-4 Parts at Repair Clinic

  • Genuine Goodman OEM Parts for the GMPN080-4 Four-Ton Platform: Control board B1809913S, igniter upgrade 0230K00001, flame sensor 0130F00010, inducer B2833001S, and blower motor B1340020S confirmed for this platform. Browse the full Goodman furnace parts catalog.
  • GMPN080-4 Rev B and GMP080 Compatibility: Parts confirmed compatible with GMPN080-4 Rev B and related GMP080 variants where applicable.
  • Goodman Fault Code Guides: Blink code reference charts and wiring diagrams available through the Goodman furnace troubleshooting section.
  • Same-Day Shipping and 365-Day Returns: Orders placed by 9:00 PM ET ship the same day. All uninstalled parts returnable within one year.

Goodman GMPN080-4 Furnace Parts FAQ

What is the control board part number for the Goodman GMPN080-4?

The control board for the GMPN080-4 is Goodman part B1809913S, the HSI board with a 9-pin connector. It manages ignition sequencing, blower timing, and safety switch monitoring. Before replacing it, read the LED fault code to confirm the fault points to the board itself rather than a sensor, igniter, or pressure switch that the board is reporting as failed.

What igniter fits the Goodman GMPN080-4 furnace?

The original igniter is Goodman part B1401018S, a silicon carbide hot surface igniter. The current OEM replacement is 0230K00001, a silicon nitride mini igniter that Goodman released as the upgraded successor. Silicon nitride is significantly more durable than silicon carbide and is the recommended replacement for any GMP or GMPN platform furnace today.

What is the difference between the Goodman GMP080 and GMPN080-4?

The GMPN designation indicates a Northern-climate variant of the GMP080 platform, typically incorporating airflow or venting calibrations suited to colder regional installation requirements. Most service parts including igniter B1401018S, flame sensor 0130F00010, control board B1809913S, and inducer motor B2833001S are shared between GMP080 and GMPN080-4. Always verify with the full model number from your data plate before ordering blower or cabinet-specific components.

What causes the Goodman GMPN080-4 to short cycle?

Short cycling on the GMPN080-4, where the furnace runs for only a few minutes before shutting off, is almost always caused by the primary limit switch opening due to heat exchanger overtemperature. The root cause is restricted airflow, most commonly a dirty air filter, a clogged blower wheel, closed supply registers, or a degraded blower motor run capacitor CAP100000370VAS. Resolve the airflow restriction before replacing the limit switch.