Goodman Furnace GMPN080-4 Parts

Shop replacement repair parts for Goodman Furnace model GMS80703ANAA

icons/furnace
Brand:Goodman
Model:GMS80703ANAA
Product:Furnace
44 results
Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a bestsellerProduct is a manufacturer part
0130F00010S Flame Sensor
$32.34

Furnace flame sensor. The flame sensor monitors the burner to detect whether or not a flame is present. If the flame sensor is defective, the furnace may not heat.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a bestsellerProduct is a manufacturer part
0131M00002PSP Draft Inducer Motor
$143.38

Furnace draft inducer motor. The draft inducer motor draws air into the burner and exhausts it out the flue. If the draft inducer motor is defective, the furnace may not heat.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a bestsellerProduct is a manufacturer part
PCBBF112S Control Board
$123.17

Furnace control board. The control board regulates the supply of power to the furnace components. Be sure to check more commonly defective parts before replacing the control board.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
B1370145 Limit Switch
$7.26

Rollout Limit Switch, 300 degrees F, Manual Reset, SPST

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
0130F00504S Pressure Switch
$40.40

Pressure switch -.6" WC SPST 1/4" barb connection

Go

Goodman GMS80703ANAA Problems & Repair Solutions

There are only a handful of issues that crop up with most appliances and equipment. Since 1912, we've learned to recognize the most common Goodman GMS80703ANAA problems ― and their solutions. Do any of these look familiar?
Furnace not heating
27 possible causes and potential solutions
Furnace not heating
Furnace is noisy or loud
10 possible causes and potential solutions
Furnace is noisy or loud
Furnace starts then stops
17 possible causes and potential solutions
Furnace starts then stops

Frequently Purchased Together For This Model

Flame Sensor
Draft Inducer Motor
Control Board
Igniter

Get your Goodman GMS80703ANAA heating reliably again with genuine OEM replacement parts from Repair Clinic. The model decodes as a GMS8 series 80% AFUE single-stage gas furnace with a 70,000 BTU input (070), a 3-ton blower (3), and an A width cabinet in the AA revision. Goodman shares engineering with Amana and Daikin. Parts replaced most often include the control board, the GMS80703ANAA draft inducer motor, the igniter, and the pressure switch. Confirm each part on the GMS80703ANAA parts list, then browse the full Goodman furnace parts catalog.

GMS80703ANAA Platform Details

This GMS80703ANAA furnace is a non-condensing 80% unit that vents through standard metal B-vent, so there is no condensate trap to service. It is not a GMPN model; parts should come from this model’s own list. The narrow A cabinet pairs the 70,000 BTU burner with a 3-ton PSC blower, which makes capacitor testing the first step for airflow complaints. The GMS80703ANAA heat exchanger relies on proper blower airflow to stay below the limit setting. The GMS80703ANAA manual and GMS80703ANAA diagram document LED codes and wiring. For GMS80703ANAA repair steps, open the model troubleshooting guide.

Most Replaced Parts on This Goodman Furnace

Draft Inducer Motor and Pressure Switch

Grinding during pre-purge or a lockout before ignition points to the draft circuit. Check the vent and tubing, confirm the inducer reaches full speed, then replace the inducer motor or pressure switch as tests indicate.

Igniter and No-Heat Starts

If draft is proven but no flame appears, inspect the GMS80703ANAA igniter for cracks or uneven glow and replace the igniter by handling only its base.

Flame Sensor and Three-Attempt Lockout

A burner that lights and drops out three times before lockout has a fouled GMS80703ANAA flame sensor. Clean it with fine emery cloth, and replace the sensor if the pattern returns.

Control Board and Blower Capacitor

Read the LED code before ordering a control board. For weak airflow, test the run capacitor against its rated value before replacing the blower motor.

Why Choose Repair Clinic for Goodman GMS80703ANAA Parts

  • Goodman, Amana, and Daikin OEM Parts: Genuine parts from the shared Goodman platform. Shop all Goodman furnace parts.
  • Correct Model Listings: GMS8 parts are listed for this model, not borrowed from GMPN or condensing GMS9 furnaces.
  • Capacitor Before Motor: Test the run capacitor before replacing the PSC blower motor.
  • Shop GMS80703ANAA Parts Online: In-stock GMS80703ANAA replacement parts and GMS80703ANAA furnace parts ship the same day with a 365-day return policy.

Goodman GMS8 Furnace FAQ

Why won’t my furnace turn on?

Read the LED code. The usual causes are a pressure switch that never closes, a cracked igniter, or a control board fault.

Is the GMS80703ANAA the same as a GMPN080-4?

No. They are different Goodman models with different inputs and blower sizes. Order GMS80703ANAA parts from this model’s list.

Does this furnace have a condensate drain?

No. It is an 80% non-condensing furnace that vents through metal B-vent, so there is no trap or condensate line.

Why does the furnace shut off after ignition?

A dirty flame sensor cannot confirm the flame, so the board closes the gas valve. Clean the rod and replace it if lockouts continue.