Goodman GMS90703BXA/P1256802 Parts

Shop replacement repair parts for Goodman Furnace model GMS90703BXA/P1256802F

icons/furnace
Brand:Goodman
Model:GMS90703BXA/P1256802F
Product:Furnace
78 results
Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a bestsellerProduct is a manufacturer part
0130F00010S Flame Sensor
$32.34

Furnace flame sensor. The flame sensor monitors the burner to detect whether or not a flame is present. If the flame sensor is defective, the furnace may not heat.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a bestsellerProduct is a manufacturer part
PCBBF112S Control Board
$123.17

Furnace control board. The control board regulates the supply of power to the furnace components. Be sure to check more commonly defective parts before replacing the control board.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a bestsellerProduct is a manufacturer part
0171M00001S Draft Inducer Motor
$197.42

Draft inducer motor replacement. If mounted horizontally, related items are needed for replacement motor. The draft inducer motor draws air into the burner and exhausts it out the flue. If the draft inducer motor is defective, the furnace may not heat.

Skill Level (1)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
0164M00107 Hose
$2.94

Pressure switch hose, sold in one foot increments

Go

Goodman GMS90703BXA/P1256802F Problems & Repair Solutions

There are only a handful of issues that crop up with most appliances and equipment. Since 1912, we've learned to recognize the most common Goodman GMS90703BXA/P1256802F problems ― and their solutions. Do any of these look familiar?
Furnace not heating
25 possible causes and potential solutions
Furnace not heating
Furnace is noisy or loud
9 possible causes and potential solutions
Furnace is noisy or loud
Furnace starts then stops
16 possible causes and potential solutions
Furnace starts then stops

Frequently Purchased Together For This Model

Flame Sensor
Control Board
Draft Inducer Motor
Igniter

Keep your Goodman GMS90703BXA/P1256802F running efficiently with genuine OEM replacement parts from Repair Clinic. The model decodes as a GMS9 series 90% AFUE single-stage condensing furnace with a 70,000 BTU input (070) and 3-ton blower (3), in the BXA revision; the P1256802F suffix is Goodman’s production identifier. Goodman shares engineering with Amana and Daikin. Parts most often replaced include the pressure switch, the draft inducer and blower motors, the igniter, and the flame sensor. Confirm each part on the GMS90703BXA/P1256802F parts list, then browse the full Goodman furnace parts catalog.

GMS90703BXA/P1256802F Condensing Furnace Details

Unlike an 80% model, this GMS90703BXA/P1256802F furnace pulls extra heat from flue gases through a secondary condensing coil. That design means PVC venting, a condensate trap, and a drain that must stay clear. The GMS90703BXA/P1256802F heat exchanger therefore has two parts: a primary section over the burners and a secondary coil where condensate forms. A blocked trap or drain is the leading cause of pressure switch lockouts on this platform. The production suffix matters most for control boards and harnesses, which can change between runs. The GMS90703BXA/P1256802F manual and GMS90703BXA/P1256802F diagram show trap location, venting, and fault codes. For GMS90703BXA/P1256802F repair steps, see the model troubleshooting guide.

Most Replaced Goodman GMS90703BXA/P1256802F Parts

Pressure Switch and Condensate Trap

Condensing furnaces use the pressure switch to prove draft and, in many cases, to detect a backed-up drain. If the code points to the pressure circuit, remove and flush the trap, clear the drain line, and check the tubing for water or cracks. Replace the pressure switch only when drainage is clear and the switch still fails to close.

Draft Inducer Motor

The GMS90703BXA/P1256802F draft inducer motor pulls combustion gases through both heat exchanger sections. Bearing noise, slow startup, or water in the housing from a drain problem shortens its life. Confirm the motor reaches full speed before blaming the switch, then order the matching inducer motor.

Igniter Failures and Cold Starts

Read the board code before replacing ignition parts. If the inducer runs and the pressure switch closes but nothing lights, inspect the GMS90703BXA/P1256802F igniter for cracks or uneven glow, and replace the igniter while handling it only by the base.

Flame Sensor and Short Cycling

Three short burner runs followed by lockout is the classic sign of a contaminated GMS90703BXA/P1256802F flame sensor. Clean the rod with fine emery cloth, and replace the flame sensor if the pattern continues.

Why Choose Repair Clinic for Goodman GMS90703BXA/P1256802F Parts

  • Goodman, Amana, and Daikin OEM Parts: Genuine parts from the shared Goodman platform. Shop all Goodman furnace parts.
  • Condensing Platform Support: Trap, drain, and pressure switch parts are listed together because they fail together on 90% furnaces.
  • Drain Before Switch Protocol: Flush the condensate trap and test the blower run capacitor before replacing a switch or motor.
  • Shop GMS90703BXA/P1256802F Parts Online: In-stock GMS90703BXA/P1256802F replacement parts and GMS90703BXA/P1256802F furnace parts ship the same day with a 365-day return policy.

Goodman GMS90703BXA Furnace FAQ

Why does my furnace show a pressure switch fault?

On this condensing furnace, a clogged condensate trap or drain is the most common cause. Flush the trap, clear the drain, and inspect the tubing before replacing the pressure switch or inducer.

What does the P1256802F part of the model number mean?

It is Goodman’s production identifier for this build. It matters most when ordering control boards and harnesses. Igniters, flame sensors, and inducers are less sensitive to it.

Why does the furnace light and then shut off?

A dirty flame sensor cannot confirm the flame, so the board closes the gas valve and retries. Clean the rod first and replace it if lockouts continue.

How do I find the correct parts diagram?

Open the diagrams and manuals tab on this page. GMS90703BXA/P1256802F parts are grouped by burner, blower, venting, and electrical sections, so you can match each one by position.