Goodman GMS90904CXA/P1256804 Parts

Shop replacement repair parts for Goodman Furnace model GMS90904CXA/P1256804F

icons/furnace
Brand:Goodman
Model:GMS90904CXA/P1256804F
Product:Furnace
77 results
Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a bestsellerProduct is a manufacturer part
0130F00010S Flame Sensor
$32.34

Furnace flame sensor. The flame sensor monitors the burner to detect whether or not a flame is present. If the flame sensor is defective, the furnace may not heat.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a bestsellerProduct is a manufacturer part
PCBBF112S Control Board
$123.17

Furnace control board. The control board regulates the supply of power to the furnace components. Be sure to check more commonly defective parts before replacing the control board.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a bestsellerProduct is a manufacturer part
0171M00001S Draft Inducer Motor
$197.42

Draft inducer motor replacement. If mounted horizontally, related items are needed for replacement motor. The draft inducer motor draws air into the burner and exhausts it out the flue. If the draft inducer motor is defective, the furnace may not heat.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a bestsellerProduct is a manufacturer part
0131F00042SP Blower Motor
$182.80

1/2HP 115Volts 60Hz 7 amp 1130 RPM's 4 Speed Open Enclosure Single Phase CCW 4" Shaft

Skill Level (1)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
0164M00107 Hose
$2.94

Pressure switch hose, sold in one foot increments

Go

Goodman GMS90904CXA/P1256804F Problems & Repair Solutions

There are only a handful of issues that crop up with most appliances and equipment. Since 1912, we've learned to recognize the most common Goodman GMS90904CXA/P1256804F problems ― and their solutions. Do any of these look familiar?
Furnace not heating
24 possible causes and potential solutions
Furnace not heating
Furnace is noisy or loud
9 possible causes and potential solutions
Furnace is noisy or loud
Furnace starts then stops
16 possible causes and potential solutions
Furnace starts then stops

Frequently Purchased Together For This Model

Flame Sensor
Control Board
Draft Inducer Motor
Igniter

Maintain dependable heat from your Goodman GMS90904CXA/P1256804F with genuine OEM replacement parts from Repair Clinic. The model decodes as a GMS9 series 90% AFUE single-stage condensing furnace with a 90,000 BTU input (090), a 4-ton blower (4), and a C width cabinet in the XA revision, and the P1256804F suffix is Goodman’s production identifier. Goodman shares engineering with Amana and Daikin. Parts replaced most often include the pressure switch, the GMS90904CXA/P1256804F draft inducer motor, the igniter, and the flame sensor. Confirm each part on the GMS90904CXA/P1256804F parts list, then browse the full Goodman furnace parts catalog.

GMS90904CXA/P1256804F Platform Details

This GMS90904CXA/P1256804F furnace fires at a single stage; it is not a two-stage unit, so there is no low and high fire sequence to diagnose. Its 90% efficiency comes from a secondary coil that condenses water from the flue gases, which means PVC venting, a condensate trap, and a drain that must stay clear. The GMS90904CXA/P1256804F heat exchanger therefore has a primary section and a secondary coil. It is the larger sibling of the 70,000 BTU GMS90703BXA/P1256802F; ignition parts may overlap, but inducers, burners, and blower parts are sized to each input. The production suffix matters most for control boards. The GMS90904CXA/P1256804F manual and GMS90904CXA/P1256804F diagram show trap location and LED codes. For GMS90904CXA/P1256804F repair steps, open the model troubleshooting guide.

Most Replaced GMS90904CXA/P1256804F Furnace Parts

Condensate Trap and Pressure Switch

When the LED points to the pressure circuit, remove and flush the trap, clear the drain, and check the tubing for water. Replace the pressure switch only when drainage is clear and it still fails to close.

Draft Inducer Motor

The inducer pulls gases through both heat exchanger sections. Bearing noise, slow spin-up, or corrosion from backed-up condensate shortens its life. Confirm full speed before blaming the switch, then order the inducer motor for the 090 size.

Igniter and Flame Sensor

If draft is proven but nothing lights, inspect the GMS90904CXA/P1256804F igniter for cracks. If the burner lights and drops out three times, clean the GMS90904CXA/P1256804F flame sensor, and replace the sensor if lockouts return.

Blower Motor and Capacitor

Weak airflow and limit trips on the 4-ton blower often trace to the run capacitor. Test it against the installed label before replacing the blower motor.

Why Choose Repair Clinic for GMS90904CXA/P1256804F Parts

  • Goodman, Amana, and Daikin OEM Parts: Genuine parts from the shared Goodman platform. Shop all Goodman furnace parts.
  • Size-Matched Listings: Inducer, burner, and blower parts are matched to the 90,000 BTU, 4-ton configuration, not the 070 sibling.
  • Drain Before Switch: Flush the trap and test the capacitor before replacing a switch or motor.
  • Shop GMS90904CXA/P1256804F Parts Online: In-stock GMS90904CXA/P1256804F replacement parts and GMS90904CXA/P1256804F furnace parts ship the same day with a 365-day return policy.

Goodman GMS90904CXA/P1256804F FAQ

Is the GMS90904CXA/P1256804F a two-stage furnace?

No. The GMS9 series is single-stage. The 090 code means 90,000 BTU input and the 4 means a 4-ton blower. Goodman’s two-stage furnaces use different series codes.

What does the P1256804F suffix mean?

It is Goodman’s production identifier for this build. It matters most when ordering control boards and harnesses; igniters and flame sensors are less sensitive to it.

Why does this furnace need a condensate drain?

At 90% efficiency, flue gases cool enough to form water in the secondary coil. That water must drain freely, or it backs up and triggers pressure switch lockouts.

What causes short cycling on this furnace?

Most often a fouled flame sensor, a blocked condensate trap, or a limit trip from a dirty filter. Clean the sensor, flush the trap, and replace the filter first.