Nordyne FG6RA 072C-12A Furnace Parts

Shop replacement repair parts for Nordyne Furnace model FG6RA 072C-12A

icons/furnace
Brand:Nordyne
Model:FG6RA 072C-12A
Product:Furnace
20 results
Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
903600 Flame Sensor
$32.11

Furnace flame sensor with wire harness

Skill Level (3)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
903106A Control Board
$575.84

Furnace control board. The control board regulates the supply of power to the furnace components. Be sure to check more commonly defective parts before replacing the control board.

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
904502 Blower Motor
$381.68

Blower motor, 1/3HP 115Volts 60Hz 1.1 amp 1075/3 RPM's Speed Open Enclosure 48Y Frame CCW 4.5" Shaft

Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
903111 Draft Inducer Motor
$317.16

Draft Inducer Motor, 115 Volts, 1.1 Amps, 60 hz, 3000 RPM, 1/50 HP. The draft inducer motor draws air into the burner and exhausts it out the flue. If the draft inducer motor is defective, the furnace may not heat.

Go

Nordyne FG6RA 072C-12A Problems & Repair Solutions

There are only a handful of issues that crop up with most appliances and equipment. Since 1912, we've learned to recognize the most common Nordyne FG6RA 072C-12A problems ― and their solutions. Do any of these look familiar?
Furnace not heating
21 possible causes and potential solutions
Furnace not heating
Furnace is noisy or loud
8 possible causes and potential solutions
Furnace is noisy or loud
Furnace starts then stops
14 possible causes and potential solutions
Furnace starts then stops

Frequently Purchased Together For This Model

Flame Sensor
Igniter
Gas Burner
Pressure Switch

Get reliable heating from your Nordyne FG6RA 072C-12A downflow manufactured home furnace with genuine OEM replacement parts from Repair Clinic. The FG6RA 072C-12A is a 72,000 BTU downflow gas furnace for manufactured and mobile home installations, the mid-range member of the FG6RA downflow series between the 060C and 096C variants; the 072C-12A indicates 72,000 BTU input in a 12-inch wide cabinet. The FG6RA 072C-12A was also sold as a Frigidaire-branded furnace on the same Nordyne platform with interchangeable service parts. In the downflow configuration, the furnace delivers heated air downward into the subfloor duct system using an inducer and pressure switch calibrated specifically for 72,000 BTU throughput in the 12-inch cabinet. Parts most frequently replaced include the hot surface igniter, flame sensor, control board, inducer motor, and pressure switch. Browse the full Nordyne furnace parts catalog.

FG6RA 072C-12A: Mid-Range Downflow Output, FG6RA Series Output-Class Distinctions, and Frigidaire Equivalence

The FG6RA 072C-12A sits between the smaller 060C and the larger 096C-16B in the FG6RA downflow series. At 72,000 BTU the 072C uses an inducer motor and pressure switch calibrated for its specific output class; these components differ from both the 060C and 096C variants and must not be cross-substituted. Like all FG6RA models, the 072C-12A was also sold under the Frigidaire brand on the same Nordyne platform. The control board is programmed for the downflow orientation and must not be substituted with an upflow Nordyne board. For diagnostic guidance, visit the Nordyne furnace troubleshooting section.

Most Replaced Parts on the Nordyne FG6RA 072C-12A

Hot Surface Igniter for the FG6RA 072C-12A

The igniter is positioned in the burner box at the top of the downflow cabinet, accessible after removing the upper access panel with power and gas disconnected. The silicon nitride element should test between 40 and 90 ohms when cold; an infinite resistance reading confirms an open-circuit failure that must be replaced. Browse Nordyne furnace igniter parts.

FG6RA 072C-12A Flame Sensor

A furnace that ignites and shuts off within two to five seconds, repeating before locking out, is showing the classic flame sensor symptom. Annual light cleaning of the sensor rod with fine steel wool is the most cost-effective preventive step. Browse Nordyne furnace flame sensor parts.

FG6RA 072C-12A Control Board

The control board is programmed for the downflow orientation and must not be substituted with an upflow Nordyne board. Read and document the LED blink pattern before ordering any replacement; the fault code chart is on the blower compartment door interior. Browse Nordyne furnace control board parts.

Draft Inducer Motor for the FG6RA 072C-12A

In the downflow configuration the inducer draws combustion gases upward through the 072C-12A heat exchanger. Moisture accumulation near the inducer housing accelerates bearing wear in the downflow orientation; a grinding sound at startup should be addressed proactively. Browse Nordyne furnace inducer motor parts.

FG6RA 072C-12A Pressure Switch

The pressure switch is calibrated for the draft characteristics of the 72,000 BTU downflow heat exchanger; it differs from the 060C and 096C variants and must not be cross-substituted. A blocked pressure hose accounts for most pressure switch faults on this platform and should always be inspected before the switch is replaced.

Nordyne FG6RA 072C-12A Parts at Repair Clinic

  • Genuine Nordyne OEM Parts for the FG6RA 072C-12A 72,000 BTU Downflow Platform: Igniter, flame sensor, control board, and inducer confirmed for the 072C output class. Browse the full Nordyne furnace parts catalog.
  • Frigidaire FG6RA 072C-Compatible Parts: Parts for the same Nordyne platform under the Frigidaire brand designation are also available with model-specific filtering.
  • Output-Class Substitution Warning: The 072C inducer and pressure switch must not be cross-substituted with 060C or 096C components; our listings document output-class-specific specifications.
  • 365-Day Returns and Fast Shipping: All FG6RA 072C-12A parts ship promptly. The Nordyne furnace troubleshooting section covers FG6RA platform fault code interpretation.

Nordyne FG6RA 072C-12A Furnace Parts FAQ

What is the difference between the FG6RA 072C-12A and FG6RA 096C-16B?

The FG6RA 072C-12A delivers 72,000 BTU in a 12-inch cabinet, while the FG6RA 096C-16B delivers 96,000 BTU in a 16-inch cabinet. The higher-output 096C model uses a larger inducer motor and pressure switch calibrated for its greater combustion gas volume; these components must not be cross-substituted between the two output classes.

My FG6RA 072C-12A has a pressure switch fault but the inducer sounds normal. What else should I check?

On the FG6RA 072C-12A, pressure switch faults with a normal-sounding inducer are most often caused by a kinked pressure hose behind displaced insulation, a cracked hose, or a blocked condensate drain tube at the inducer housing. Inspect the full hose length before replacing the switch; a clear, intact hose with a switch that still reads open at normal operating draft confirms a failed switch diaphragm.

Can I use FG6RC parts in my FG6RA furnace?

The FG6RA and FG6RC are different product lines at different BTU configurations. The FG6RA 072C-12A uses components sized for 72,000 BTU; the FG6RC series covers different output classes. Always confirm the specific part number from the installed component label before ordering to verify compatibility rather than assuming cross-series interchangeability.

Why does my FG6RA 072C-12A ignite briefly and then shut off?

A furnace that lights and shuts off within two to five seconds is showing the classic flame sensor symptom; the sensor’s micro-amp current has dropped below the control board detection threshold. Clean the sensor rod lightly with fine steel wool and test; replace the rod if the symptom recurs within the same heating season after cleaning.