Carrier 38TKB030-300-9 Central Air Conditioner Parts

Shop replacement repair parts for Carrier Central Air Conditioner model 38TKB030-300-9

icons/central air condenser
Brand:Carrier
Model:38TKB030-300-9
Product:Central Air Conditioner
71 results
Skill Level (2)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
HN51KC024 Contactor
$71.91

You need Contactor HN51KC024 if you're having trouble with the compressor or fan motor on your air conditioner, furnace, heat pump, or air handler. This genuine OEM single-pole, 24-volt coil contactor has a full load amps (FLA) rating of 30 amps and a locked rotor amps (LRA) rating of 150 amps.

Product is a manufacturer part
Triple-D-AER Cleaner
$26.10

Triple-D Coil Cleaner is a 19oz Aerosol spray can, that is safe for homeowner use. One can will clean an entire outdoor condenser coil and/or indoor evaporator coil, to remove energy-stealing dirt, debris and soot.

Skill Level (3)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
HC33GE233 Condenser Fan Motor
$343.95

Condenser fan motor. This single-phase motor has the following specifications:

Horsepower: 1/10
Voltage: 208-230
Full-Load Amperage: 0.75
Hertz: 60
RPM: 1075
Rotation: Clockwise
Frame: 48
Enclosure: Closed
Shaft Length: 1.75”

Skill Level (1)
skill level dotskill level dotskill level dotskill level dot
Product is a manufacturer part
21986 Pump
$102.51

Condensate Pump.
Features:
* 16 foot lift
* Whisper quiet
* ½ Gallon Reservoir
* Rubber isolation feet
* 3/8" Check Valve

Go

Carrier 38TKB030-300-9 Problems & Repair Solutions

There are only a handful of issues that crop up with most appliances and equipment. Since 1912, we've learned to recognize the most common Carrier 38TKB030-300-9 problems ― and their solutions. Do any of these look familiar?

Frequently Purchased Together For This Model

Contactor
Screw
Dual Run Capacitor
Nut

Service your Carrier 38TKB030-300-9 central air conditioner with genuine OEM replacement parts from Repair Clinic. The 38TKB030-300-9 is a 2.5-ton single-stage cooling-only condensing unit in Carrier’s 38TKB series, one output class below the 3-ton 38TKB036-300-9 in the same platform generation. The carrier 38tkb030300 and 38TKB030-300-9 designations refer to the same unit. At 2.5-ton output, the Carrier 38TKB030 fan motor and fan blade are sized for the smaller condenser coil and are not interchangeable with the 3-ton 38TKB036 components. Parts most frequently replaced on the 38TKB030-300-9 include the run capacitor, contactor, condenser fan motor, and fan blade. Use the 38TKB030-300-9 parts list and browse the full Carrier central air conditioner parts catalog.

38TKB030-300-9 in the 38TKB Series: 2.5-Ton Output Class and Cross-Model Substitution Warnings

The carrier 38tkb030 occupies the 2.5-ton position in Carrier’s 38TKB condensing unit line, alongside the 38TKB036 (3-ton) and 38TKB060 (5-ton) configurations. The 38TKB030 tonnage designation is critical for parts ordering: the fan motor draws air for a 2.5-ton condenser coil and produces incorrect airflow in the 3-ton or 5-ton cabinets, and vice versa. The Carrier 38TKB030300 tonnage is confirmed as 2.5 tons from the 030 designation in the model number; the Carrier 38TKB030 tonnage does not vary within the 030 output class regardless of the cabinet revision suffix. The 38tkb060330 is a 5-ton variant in the same 38TKB series; its components are not interchangeable with the 38TKB030. The 38TKB030-300-9 manual documents refrigerant charge specification and electrical data for the 2.5-ton configuration. For diagnostic guidance, visit the Carrier air conditioner troubleshooting section.

38TKB030-300-9 Electrical Component Failures and Service Priorities

38TKB030-300-9 Capacitor and 2.5-Ton Compressor Sensitivity

The 38TKB030-300-9 capacitor is a dual-run unit serving the 2.5-ton compressor and condenser fan motor. Annual microfarad testing at cooling season start is the highest-impact preventive maintenance step; replace the capacitor when either section reads more than five percent below the rated value on the label. A compressor that hums and trips thermal protection while the fan runs normally confirms a failed compressor section. Browse Carrier central air conditioner capacitor parts.

Carrier 38TKB030 Contactor Inspection and Service Interval

The contactor on the carrier 38tkb030 switches line voltage to the 2.5-ton compressor and condenser fan motor at every thermostat cooling cycle. Inspect the contact faces at each annual service; replace the contactor when any pitting or erosion is visible, or proactively every five to seven years. Find compatible options at the Carrier air conditioner contactor page.

38TKB030-300-9 Fan Motor Output-Class Confirmation Before Ordering

The 38TKB030-300-9 fan motor is sized for the 2.5-ton condenser coil’s airflow requirement. A motor from the 38TKB036 (3-ton) configuration installed in the 030 cabinet produces excess airflow for the 2.5-ton coil. Always confirm the 030 output class designation when ordering a fan motor for the 38TKB030-300-9. Browse Carrier central air conditioner fan motor parts.

38TKB030-300-9 Fan Blade Physical Inspection and Specification Matching

The fan blade on the 38TKB030-300-9 must be pitched for the 2.5-ton coil’s airflow requirement at the motor’s rated RPM. Inspect the blade annually for tip damage, hub cracking, and surface corrosion that create imbalance and accelerate motor bearing wear. Confirm the blade diameter, pitch, and hub bore from the 38TKB030-300-9 parts list before ordering. Browse Carrier air conditioner fan blade parts.

Carrier 38TKB030-300-9 Parts at Repair Clinic

  • 2.5-Ton Output Class Verified Carrier OEM Parts: Our 38TKB030-300-9 listings distinguish 030-class components from 036 and 060 configurations in the same 38TKB series. Browse the full Carrier central air conditioner parts catalog.
  • Carrier 38TKB030300 Tonnage Documented: Our listings confirm the Carrier 38TKB030300 tonnage as 2.5 tons from the 030 output class designation, preventing ordering errors when searching by tonnage.
  • 38TKB030-300-9 Parts List and Diagram Access: The interactive diagram identifies components by position in the 2.5-ton cabinet before ordering.
  • Fast Shipping During Cooling Season: In-stock 38TKB030-300-9 parts ship promptly, supported by the Carrier air conditioner troubleshooting section.

Carrier 38TKB030-300-9 Central Air Conditioner Parts FAQ

What is the Carrier 38TKB030300 tonnage?

The Carrier 38TKB030300 tonnage is 2.5 tons (30,000 BTU). The 030 in the model number directly identifies the 30,000 BTU capacity class. This determines the fan motor RPM and torque requirements, the fan blade pitch and diameter, and the capacitor specification for the compressor section; none of these components are interchangeable with 36,000 BTU (036) or 60,000 BTU (060) 38TKB configurations.

Are the 38TKB030-300-9 and 38TKB036-300-9 fan motors interchangeable?

No. The 38TKB030 motor is sized for the 2.5-ton coil and the 38TKB036 motor is sized for the 3-ton coil; these are different output class components within the same 38TKB platform. Installing a 036-class motor in the 030 cabinet produces excess airflow for the smaller 2.5-ton coil configuration.

Is the 38TKB030-300-9 the same as the carrier 38tkb030300?

Yes. The carrier 38tkb030300 and 38TKB030-300-9 are alternate designations for the same 2.5-ton 38TKB condensing unit; the hyphenated form is the formal Carrier model number and the unhyphenated form is commonly used in parts catalog searches. Parts ordered under either designation are correct for the same unit.

Does Repair Clinic carry parts for the 38TKB060330 as well?

Yes. The 38tkb060330 is a 5-ton variant in the same 38TKB series generation. Parts for the 38TKB060 are stocked separately from the 38TKB030 and 38TKB036 configurations because the fan motor, fan blade, and capacitor specifications differ across the 030, 036, and 060 output classes. Search by the full 38TKB060 model number to access the correct 5-ton components.