Maintain your RAKA-018JAZ central air conditioner running efficiently with genuine OEM replacement parts from Repair Clinic. The RAKA-018JAZ is a one-and-a-half-ton R-22 residential outdoor condensing unit using R-22 refrigerant. Rheem and Ruud are sister brands under the same parent company. RAKA is the Rheem brand designation for this residential outdoor condensing unit series, with the equivalent Ruud model carrying the RKKA designation at the same configuration. The dual run capacitor, contactor, and outdoor fan motor account for the vast majority of service calls. Repair Clinic stocks genuine Rheem OEM parts for the RAKA-018JAZ including the Rheem capacitor parts, Rheem contactor parts, Rheem fan motor parts, and Rheem high-pressure switch parts. Browse the Rheem central air conditioner parts catalog filtered by RAKA-018JAZ for the complete parts inventory.
RAKA-018JAZ: One-And-A-Half-Ton R-22 Outdoor Condensing Unit Service
Annual capacitance testing of the dual run capacitor before the cooling season is the most cost-effective preventive maintenance step for the RAKA-018JAZ. Match all microfarad values from the installed capacitor label before ordering a replacement. The central air conditioner repair help section covers capacitor testing and contactor diagnosis for this platform.
Most Replaced Parts on the RAKA-018JAZ
Dual Run Capacitor for the RAKA-018JAZ
The dual run capacitor provides starting and running torque for both the compressor and outdoor fan motor. A reading more than 10% below the rated value causes the compressor to hard-start. Match all three microfarad values from the installed capacitor label before ordering.
RAKA-018JAZ Contactor
The contactor closes the 240-volt compressor circuit at every cooling cycle start. Pitted or burned contacts generate heat that transfers to the compressor motor terminals. Replace a contactor with visibly eroded contacts before compressor winding damage occurs.
Outdoor Fan Motor for the RAKA-018JAZ
The outdoor fan motor pulls air through the condenser coil. Test the run capacitor before ordering a replacement motor, as a failed capacitor produces identical slow-start symptoms at a fraction of the motor replacement cost.
High-Pressure Switch for the RAKA-018JAZ
A high-pressure switch that trips repeatedly under normal ambient conditions points to a blocked condenser coil, failed fan motor, or refrigerant overcharge rather than a failed switch diaphragm.
Why Choose Repair Clinic for RAKA-018JAZ Parts
- Genuine Rheem RAKA OEM Components: One-and-a-half-ton dual run capacitors, contactors, and fan motors confirmed for the RAKA-018JAZ R-22 platform with Ruud cross-reference Rheem central air conditioner parts.
- R-22 Refrigerant Circuit Context: The RAKA-018JAZ uses R-22 refrigerant. Refrigerant circuit service requires EPA 608 certified technicians with access to reclaimed R-22.
- Annual Capacitor Testing Priority: Pre-season capacitance testing is the most cost-effective preventive maintenance step for the RAKA-018JAZ.
- 365-Day Returns: Return any uninstalled part within a full year of purchase with no restocking fees.
RAKA-018JAZ Parts FAQ
What is the RAKA-018JAZ and what ton size is it?
The RAKA-018JAZ is a one-and-a-half-ton R-22 residential outdoor condensing unit using R-22 refrigerant. Rheem and Ruud are sister brands under the same parent company. RAKA is the Rheem brand designation for this residential outdoor condensing unit series, with the equivalent Ruud model carrying the RKKA designation at the same configuration.
Why does my RAKA-018JAZ hum but not start?
A unit that hums but does not start has most commonly failed at the dual run capacitor. Test the capacitor with a digital capacitance meter before testing any other component.
How does the Rheem RAKA-018JAZ differ from the RAKA-024JAZ?
The RAKA-018JAZ is a one-and-a-half-ton unit while the RAKA-024JAZ is a two-ton unit in the same Rheem RAKA R-22 product line. The dual run capacitor carries different compressor-section microfarad ratings between the two tonnages.
How often should I test the capacitor on the RAKA-018JAZ?
Test the capacitor annually before the cooling season. A reading more than 10% below the rated microfarad value indicates a weakening capacitor that should be replaced before it fails under peak summer load.